• Je něco špatně v tomto záznamu ?

Comparison between optical and digital blur using near visual acuity

D. Kordek, LK. Young, J. Kremláček

. 2021 ; 11 (1) : 3437. [pub] 20210209

Jazyk angličtina Země Velká Británie

Typ dokumentu klinické zkoušky, srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22004621

In a low-cost laboratory setup, we compared visual acuity (VA) for stimuli rendered with Zernike aberrations to an equivalent optical dioptric defocus in emmetropic individuals using a relatively short observing distance of 60 cm. The equivalent spherical refractive error of + 1, + 2 or + 4 D, was applied in the rendering of Landolt Rings. Separately, the refractive error was introduced dioptrically in: (1) unchanged Landolt Rings with an added external lens (+ 1, + 2 or + 4 D) at the subject's eye; (2) same as (1) but with an added accommodation and a vertex distance adjustment. To compare all three approaches, we examined VA in 10 healthy men. Stimuli were observed on a PC CRT screen. For all three levels of refractive error, the pairwise comparison did not show a statistically significant difference between digital blur and accommodation-plus-vertex-distance-adjusted dioptric blur (p < 0.204). The best agreement, determined by Bland-Altman analysis, was measured for + 4 D and was in line with test-retest limits for examination in the clinical population. Our results show that even for a near observing distance, it is possible to use digitally rendered defocus to replicate dioptric blur without a significant change in VA in emmetropic subjects.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22004621
003      
CZ-PrNML
005      
20220127145117.0
007      
ta
008      
220113s2021 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/s41598-021-82965-z $2 doi
035    __
$a (PubMed)33564011
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Kordek, David $u Department of Medical Biophysics, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic
245    10
$a Comparison between optical and digital blur using near visual acuity / $c D. Kordek, LK. Young, J. Kremláček
520    9_
$a In a low-cost laboratory setup, we compared visual acuity (VA) for stimuli rendered with Zernike aberrations to an equivalent optical dioptric defocus in emmetropic individuals using a relatively short observing distance of 60 cm. The equivalent spherical refractive error of + 1, + 2 or + 4 D, was applied in the rendering of Landolt Rings. Separately, the refractive error was introduced dioptrically in: (1) unchanged Landolt Rings with an added external lens (+ 1, + 2 or + 4 D) at the subject's eye; (2) same as (1) but with an added accommodation and a vertex distance adjustment. To compare all three approaches, we examined VA in 10 healthy men. Stimuli were observed on a PC CRT screen. For all three levels of refractive error, the pairwise comparison did not show a statistically significant difference between digital blur and accommodation-plus-vertex-distance-adjusted dioptric blur (p < 0.204). The best agreement, determined by Bland-Altman analysis, was measured for + 4 D and was in line with test-retest limits for examination in the clinical population. Our results show that even for a near observing distance, it is possible to use digitally rendered defocus to replicate dioptric blur without a significant change in VA in emmetropic subjects.
650    12
$a akomodace oka $7 D000065
650    _2
$a dospělí $7 D000328
650    12
$a emetropie $7 D058453
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a refrakční vady $x patofyziologie $7 D012030
655    _2
$a klinické zkoušky $7 D016430
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Young, Laura K $u Biosciences Institute, Faculty of Medical Sciences, Newcastle University, Newcastle, UK $u Department of Experimental Psychology, University of Oxford, Oxford, UK
700    1_
$a Kremláček, Jan $u Department of Medical Biophysics, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic. jan.kremlacek@lfhk.cuni.cz $u Department of Pathological Physiology, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic. jan.kremlacek@lfhk.cuni.cz
773    0_
$w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 11, č. 1 (2021), s. 3437
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33564011 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127145113 $b ABA008
999    __
$a ok $b bmc $g 1751933 $s 1155770
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 11 $c 1 $d 3437 $e 20210209 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...