Liquid chromatography method with tandem mass spectrometry and fluorescence detection for determination of inflammatory biomarkers in gingival crevicular fluid as a tool for diagnosis of periodontal disease

A. Vernerová, LK. Krčmová, O. Heneberk, V. Radochová, F. Švec

. 2022 ; 212 (-) : 114644. [pub] 20220204

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22010713

The new ultra-high performance liquid chromatography method with tandem mass spectrometry and fluorescence detection allowing fast, selective, and high-throughput analysis of neopterin, kynurenine, tryptophan, and creatinine in gingival crevicular fluid (GCF) has been optimized. Defining the pathophysiology of periodontal disease and identification of potential diagnostic test for active periodontitis remains a significant challenge in the field of oral disease diagnosis. Analysis of GCF provides a non-invasive means of evaluating the role of the host response in periodontal disease. In addition, the analysis of GCF provides an information about current inflammation level of sampled site/tooth. Determination of GCF inflammatory biomarkers such as neopterin, kynurenine, and tryptophan can contribute to diagnosis, evaluation of treatment, and progression of periodontal diseases such as gingivitis and periodontitis. The separation of target analytes was carried out using a column KinetexTM Polar C18 100 Å, (100 × 3.0 mm) packed with 2.6 μm core-shell particles applying an elution with a gradient formed from 0.2% aqueous formic acid and 90% aqueous acetonitrile. Kynurenine, tryptophan, and creatinine were detected using mass spectrometry with electrospray ionization to improve the sensitivity while neopterin was detected using fluorescence detection. The separation of these four substances was achieved after using a very simple sample preparation technique convenient for small amount of biological sample. Only less than 20 μL sample was needed and the separation was completed in 4 min. MS/MS analysis was performed using multiple reaction monitoring (MRM) under a positive ionization mode. Deuterium labeled internal standard was used for the more precise quantification. The lower limits of quantification (LLOQ) for target analytes were 0.50 × 10-3 μmol/L for neopterin, 0.10 μmol/L for kynurenine, and 0.20 μmol/L for tryptophan and creatinine. The within-run and between-run accuracy were in a range of 96.67-114.77% for all quality controls and LLOQ of all analytes. Matrix effect, extraction recovery, and stability testing have all been investigated. The method was tested with real-life samples using GCF collected from patients suffering from periodontitis and from healthy controls. Neopterin levels in patients were significantly higher (P = 0.020) than in healthy subjects and indicate good potential of this method for using in evaluation of periodontal pathogenesis and healing outcomes following a treatment.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22010713
003      
CZ-PrNML
005      
20220506130046.0
007      
ta
008      
220425s2022 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jpba.2022.114644 $2 doi
035    __
$a (PubMed)35151070
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Vernerová, Andrea $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203/8, Hradec Králové 500 05, Czech Republic; Department of Clinical Biochemistry and Diagnostics, University Hospital, Sokolská 581, Hradec Králové 500 05, Czech Republic. Electronic address: verneran@faf.cuni.cz
245    10
$a Liquid chromatography method with tandem mass spectrometry and fluorescence detection for determination of inflammatory biomarkers in gingival crevicular fluid as a tool for diagnosis of periodontal disease / $c A. Vernerová, LK. Krčmová, O. Heneberk, V. Radochová, F. Švec
520    9_
$a The new ultra-high performance liquid chromatography method with tandem mass spectrometry and fluorescence detection allowing fast, selective, and high-throughput analysis of neopterin, kynurenine, tryptophan, and creatinine in gingival crevicular fluid (GCF) has been optimized. Defining the pathophysiology of periodontal disease and identification of potential diagnostic test for active periodontitis remains a significant challenge in the field of oral disease diagnosis. Analysis of GCF provides a non-invasive means of evaluating the role of the host response in periodontal disease. In addition, the analysis of GCF provides an information about current inflammation level of sampled site/tooth. Determination of GCF inflammatory biomarkers such as neopterin, kynurenine, and tryptophan can contribute to diagnosis, evaluation of treatment, and progression of periodontal diseases such as gingivitis and periodontitis. The separation of target analytes was carried out using a column KinetexTM Polar C18 100 Å, (100 × 3.0 mm) packed with 2.6 μm core-shell particles applying an elution with a gradient formed from 0.2% aqueous formic acid and 90% aqueous acetonitrile. Kynurenine, tryptophan, and creatinine were detected using mass spectrometry with electrospray ionization to improve the sensitivity while neopterin was detected using fluorescence detection. The separation of these four substances was achieved after using a very simple sample preparation technique convenient for small amount of biological sample. Only less than 20 μL sample was needed and the separation was completed in 4 min. MS/MS analysis was performed using multiple reaction monitoring (MRM) under a positive ionization mode. Deuterium labeled internal standard was used for the more precise quantification. The lower limits of quantification (LLOQ) for target analytes were 0.50 × 10-3 μmol/L for neopterin, 0.10 μmol/L for kynurenine, and 0.20 μmol/L for tryptophan and creatinine. The within-run and between-run accuracy were in a range of 96.67-114.77% for all quality controls and LLOQ of all analytes. Matrix effect, extraction recovery, and stability testing have all been investigated. The method was tested with real-life samples using GCF collected from patients suffering from periodontitis and from healthy controls. Neopterin levels in patients were significantly higher (P = 0.020) than in healthy subjects and indicate good potential of this method for using in evaluation of periodontal pathogenesis and healing outcomes following a treatment.
650    _2
$a biologické markery $x analýza $7 D015415
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a chromatografie kapalinová $7 D002853
650    _2
$a gingivální exsudát $x chemie $7 D005883
650    _2
$a lidé $7 D006801
650    12
$a parodontitida $x diagnóza $7 D010518
650    12
$a tandemová hmotnostní spektrometrie $7 D053719
655    _2
$a časopisecké články $7 D016428
700    1_
$a Krčmová, Lenka Kujovská $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203/8, Hradec Králové 500 05, Czech Republic; Department of Clinical Biochemistry and Diagnostics, University Hospital, Sokolská 581, Hradec Králové 500 05, Czech Republic. Electronic address: lenkakrcmova@seznam.cz
700    1_
$a Heneberk, Ondřej $u Department of Dentistry, Faculty of Medicine in Hradec Králové, Charles University, University Hospital, Sokolská 581, Hradec Králové 500 05, Czech Republic
700    1_
$a Radochová, Vladimíra $u Department of Dentistry, Faculty of Medicine in Hradec Králové, Charles University, University Hospital, Sokolská 581, Hradec Králové 500 05, Czech Republic
700    1_
$a Švec, František $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203/8, Hradec Králové 500 05, Czech Republic
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 212, č. - (2022), s. 114644
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35151070 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220425 $b ABA008
991    __
$a 20220506130038 $b ABA008
999    __
$a ok $b bmc $g 1788720 $s 1161911
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 212 $c - $d 114644 $e 20220204 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
LZP    __
$a Pubmed-20220425

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...