Arterial Aging Best Reflected in Pulse Wave Velocity Measured from Neck to Lower Limbs: A Whole-Body Multichannel Bioimpedance Study
L. Soukup, P. Jurak, J. Halamek, I. Viscor, M. Matejkova, P. Leinveber, V. Vondra
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
35271057
DOI
10.3390/s22051910
Knihovny.cz E-zdroje
- MeSH
- analýza pulzové vlny * metody MeSH
- arteriae carotides MeSH
- dolní končetina MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- stárnutí * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Pulse wave velocity is a commonly used parameter for evaluating arterial stiffness and the overall condition of the cardiovascular system. The main goal of this study was to establish a methodology to test and validate multichannel bioimpedance as a suitable method for whole-body evaluations of pulse waves. We set the proximal location over the left carotid artery and eight distal locations on both the upper and lower limbs. In this way, it was possible to simultaneously evaluate pulse wave velocity (PWV) in the upper and lower limbs and in the limbs via four extra PWV measurements. Data were acquired from a statistical group of 220 healthy subjects who were divided into three age groups. The data were then analysed. We found a significant dependency of aortic PWV on age in those values measured using the left carotid as the proximal. PWV values in the upper and lower limbs were found to have no significant dependency on age. In addition, the PWV in the left femoral artery shows comparable values to published already carotid-femoral values. Those findings prove the reliability of whole-body multichannel bioimpedance for pulse wave velocity evaluation and provide reference values for whole-body PWV measurement.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22010919
- 003
- CZ-PrNML
- 005
- 20220506130428.0
- 007
- ta
- 008
- 220425s2022 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s22051910 $2 doi
- 035 __
- $a (PubMed)35271057
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Soukup, Ladislav $u The International Clinical Research Center, St. Anne's University Hospital Brno, 656 91 Brno, Czech Republic $1 https://orcid.org/000000031517687X
- 245 10
- $a Arterial Aging Best Reflected in Pulse Wave Velocity Measured from Neck to Lower Limbs: A Whole-Body Multichannel Bioimpedance Study / $c L. Soukup, P. Jurak, J. Halamek, I. Viscor, M. Matejkova, P. Leinveber, V. Vondra
- 520 9_
- $a Pulse wave velocity is a commonly used parameter for evaluating arterial stiffness and the overall condition of the cardiovascular system. The main goal of this study was to establish a methodology to test and validate multichannel bioimpedance as a suitable method for whole-body evaluations of pulse waves. We set the proximal location over the left carotid artery and eight distal locations on both the upper and lower limbs. In this way, it was possible to simultaneously evaluate pulse wave velocity (PWV) in the upper and lower limbs and in the limbs via four extra PWV measurements. Data were acquired from a statistical group of 220 healthy subjects who were divided into three age groups. The data were then analysed. We found a significant dependency of aortic PWV on age in those values measured using the left carotid as the proximal. PWV values in the upper and lower limbs were found to have no significant dependency on age. In addition, the PWV in the left femoral artery shows comparable values to published already carotid-femoral values. Those findings prove the reliability of whole-body multichannel bioimpedance for pulse wave velocity evaluation and provide reference values for whole-body PWV measurement.
- 650 12
- $a stárnutí $7 D000375
- 650 _2
- $a arteriae carotides $7 D002339
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a dolní končetina $7 D035002
- 650 12
- $a analýza pulzové vlny $x metody $7 D063177
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Jurak, Pavel $u The International Clinical Research Center, St. Anne's University Hospital Brno, 656 91 Brno, Czech Republic $u The Institute of Scientific Instruments of the CAS, v.v.i, 612 64 Brno, Czech Republic
- 700 1_
- $a Halamek, Josef $u The International Clinical Research Center, St. Anne's University Hospital Brno, 656 91 Brno, Czech Republic $u The Institute of Scientific Instruments of the CAS, v.v.i, 612 64 Brno, Czech Republic $1 https://orcid.org/000000018986796X
- 700 1_
- $a Viscor, Ivo $u The Institute of Scientific Instruments of the CAS, v.v.i, 612 64 Brno, Czech Republic $1 https://orcid.org/0000000242983610 $7 xx0273674
- 700 1_
- $a Matejkova, Magdalena $u The International Clinical Research Center, St. Anne's University Hospital Brno, 656 91 Brno, Czech Republic
- 700 1_
- $a Leinveber, Pavel $u The International Clinical Research Center, St. Anne's University Hospital Brno, 656 91 Brno, Czech Republic $u The Institute of Scientific Instruments of the CAS, v.v.i, 612 64 Brno, Czech Republic
- 700 1_
- $a Vondra, Vlastimil $u The International Clinical Research Center, St. Anne's University Hospital Brno, 656 91 Brno, Czech Republic $u The Institute of Scientific Instruments of the CAS, v.v.i, 612 64 Brno, Czech Republic
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 22, č. 5 (2022)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35271057 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220425 $b ABA008
- 991 __
- $a 20220506130420 $b ABA008
- 999 __
- $a ok $b bmc $g 1788842 $s 1162117
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 22 $c 5 $e 20220301 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- LZP __
- $a Pubmed-20220425