-
Je něco špatně v tomto záznamu ?
Interrater Agreement and Detection Accuracy for Medium-Vessel Occlusions Using Single-Phase and Multiphase CT Angiography
JM. Ospel, F. Bala, RV. McDonough, O. Volny, N. Kashani, W. Qiu, BK. Menon, M. Goyal
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
CIHR - Canada
PubMed
34824099
DOI
10.3174/ajnr.a7361
Knihovny.cz E-zdroje
- MeSH
- cévní mozková příhoda * diagnostické zobrazování MeSH
- CT angiografie MeSH
- ischemická cévní mozková příhoda * MeSH
- ischemie mozku * MeSH
- lidé MeSH
- mozková angiografie MeSH
- retrospektivní studie MeSH
- trombektomie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND AND PURPOSE: Accurate and reliable detection of medium-vessel occlusions is important to establish the diagnosis of acute ischemic stroke and initiate appropriate treatment with intravenous thrombolysis or endovascular thrombectomy. However, medium-vessel occlusions are often challenging to detect, especially for unexperienced readers. We aimed to evaluate the accuracy and interrater agreement of the detection of medium-vessel occlusions using single-phase and multiphase CTA. MATERIALS AND METHODS: Single-phase and multiphase CTA of 120 patients with acute ischemic stroke (20 with no occlusion, 44 with large-vessel occlusion, and 56 with medium-vessel occlusion in the anterior and posterior circulation) were assessed by 3 readers with varying levels of experience (session 1: single-phase CTA; session 2: multiphase CTA). Interrater agreement for occlusion type (large-vessel occlusion versus medium-vessel occlusion versus no occlusion) and for detailed occlusion sites was calculated using the Fleiss κ with 95% confidence intervals. Accuracy for the detection of medium-vessel occlusions was calculated for each reader using classification tables. RESULTS: Interrater agreement for occlusion type was moderate for single-phase CTA (κ = 0.58; 95% CI, 0.56-0.62) and almost perfect for multiphase CTA (κ = 0.81; 95% CI, 0.78-0.83). Interrater agreement for detailed occlusion sites was moderate for single-phase CTA (κ = 0.55; 95% CI, 0.53-0.56) and substantial for multiphase CTA (κ = 0.71; 95% CI, 0.67-0.74). On single-phase CTA, readers 1, 2, and 3 classified 33/56 (59%), 34/56 (61%), and 32/56 (57%) correctly as medium-vessel occlusions. On multiphase CTA, 48/56 (86%), 50/56 (89%), and 50/56 (89%) medium-vessel occlusions were classified correctly. CONCLUSIONS: Interrater agreement for medium-vessel occlusions is moderate when using single-phase CTA and almost perfect with multiphase CTA. Detection accuracy is substantially higher with multiphase CTA compared with single-phase CTA, suggesting that multiphase CTA might be a valuable tool for assessment of medium-vessel occlusion stroke.
Department of Clinical Neurosciences University of Calgary Calgary Alberta Canada
Department of Neurology University Hospital Ostrava Ostrava Czech
Department of Radiology University Hospital of Basel Basel Switzerland
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22011414
- 003
- CZ-PrNML
- 005
- 20220506130457.0
- 007
- ta
- 008
- 220425s2022 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3174/ajnr.A7361 $2 doi
- 035 __
- $a (PubMed)34824099
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Ospel, J M $u From the Department of Diagnostic Imaging (J.M.O., F.B., R.V.M., N.K., W.Q., B.K.M., M.G.) $u Department of Radiology (J.M.O.), University Hospital of Basel, Basel, Switzerland $1 https://orcid.org/0000000300296764
- 245 10
- $a Interrater Agreement and Detection Accuracy for Medium-Vessel Occlusions Using Single-Phase and Multiphase CT Angiography / $c JM. Ospel, F. Bala, RV. McDonough, O. Volny, N. Kashani, W. Qiu, BK. Menon, M. Goyal
- 520 9_
- $a BACKGROUND AND PURPOSE: Accurate and reliable detection of medium-vessel occlusions is important to establish the diagnosis of acute ischemic stroke and initiate appropriate treatment with intravenous thrombolysis or endovascular thrombectomy. However, medium-vessel occlusions are often challenging to detect, especially for unexperienced readers. We aimed to evaluate the accuracy and interrater agreement of the detection of medium-vessel occlusions using single-phase and multiphase CTA. MATERIALS AND METHODS: Single-phase and multiphase CTA of 120 patients with acute ischemic stroke (20 with no occlusion, 44 with large-vessel occlusion, and 56 with medium-vessel occlusion in the anterior and posterior circulation) were assessed by 3 readers with varying levels of experience (session 1: single-phase CTA; session 2: multiphase CTA). Interrater agreement for occlusion type (large-vessel occlusion versus medium-vessel occlusion versus no occlusion) and for detailed occlusion sites was calculated using the Fleiss κ with 95% confidence intervals. Accuracy for the detection of medium-vessel occlusions was calculated for each reader using classification tables. RESULTS: Interrater agreement for occlusion type was moderate for single-phase CTA (κ = 0.58; 95% CI, 0.56-0.62) and almost perfect for multiphase CTA (κ = 0.81; 95% CI, 0.78-0.83). Interrater agreement for detailed occlusion sites was moderate for single-phase CTA (κ = 0.55; 95% CI, 0.53-0.56) and substantial for multiphase CTA (κ = 0.71; 95% CI, 0.67-0.74). On single-phase CTA, readers 1, 2, and 3 classified 33/56 (59%), 34/56 (61%), and 32/56 (57%) correctly as medium-vessel occlusions. On multiphase CTA, 48/56 (86%), 50/56 (89%), and 50/56 (89%) medium-vessel occlusions were classified correctly. CONCLUSIONS: Interrater agreement for medium-vessel occlusions is moderate when using single-phase CTA and almost perfect with multiphase CTA. Detection accuracy is substantially higher with multiphase CTA compared with single-phase CTA, suggesting that multiphase CTA might be a valuable tool for assessment of medium-vessel occlusion stroke.
- 650 12
- $a ischemie mozku $7 D002545
- 650 _2
- $a mozková angiografie $7 D002533
- 650 _2
- $a CT angiografie $7 D000072226
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a ischemická cévní mozková příhoda $7 D000083242
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 12
- $a cévní mozková příhoda $x diagnostické zobrazování $7 D020521
- 650 _2
- $a trombektomie $7 D017131
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Bala, F $u From the Department of Diagnostic Imaging (J.M.O., F.B., R.V.M., N.K., W.Q., B.K.M., M.G.) $1 https://orcid.org/0000000167482081
- 700 1_
- $a McDonough, R V $u From the Department of Diagnostic Imaging (J.M.O., F.B., R.V.M., N.K., W.Q., B.K.M., M.G.) $1 https://orcid.org/0000000280604490
- 700 1_
- $a Volny, O $u Czech National Centre for Evidence-Based Healthcare and Knowledge Translation (O.V.), Masaryk University, Brno, Czech $u Department of Neurology (O.V.), University Hospital Ostrava, Ostrava, Czech $1 https://orcid.org/0000000205466921 $7 ola2015886726
- 700 1_
- $a Kashani, N $u From the Department of Diagnostic Imaging (J.M.O., F.B., R.V.M., N.K., W.Q., B.K.M., M.G.) $u Department of Clinical Neurosciences (N.K., B.K.M., M.G.), University of Calgary, Calgary, Alberta, Canada $1 https://orcid.org/000000029752784X
- 700 1_
- $a Qiu, W $u From the Department of Diagnostic Imaging (J.M.O., F.B., R.V.M., N.K., W.Q., B.K.M., M.G.) $1 https://orcid.org/0000000178278270
- 700 1_
- $a Menon, B K $u From the Department of Diagnostic Imaging (J.M.O., F.B., R.V.M., N.K., W.Q., B.K.M., M.G.) $u Department of Clinical Neurosciences (N.K., B.K.M., M.G.), University of Calgary, Calgary, Alberta, Canada $1 https://orcid.org/000000023466496X
- 700 1_
- $a Goyal, M $u From the Department of Diagnostic Imaging (J.M.O., F.B., R.V.M., N.K., W.Q., B.K.M., M.G.) mgoyal@ucalgary.ca $u Department of Clinical Neurosciences (N.K., B.K.M., M.G.), University of Calgary, Calgary, Alberta, Canada $1 https://orcid.org/0000000190602109
- 773 0_
- $w MED00009116 $t AJNR. American journal of neuroradiology $x 1936-959X $g Roč. 43, č. 1 (2022), s. 93-97
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34824099 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220425 $b ABA008
- 991 __
- $a 20220506130449 $b ABA008
- 999 __
- $a ok $b bmc $g 1789149 $s 1162612
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 43 $c 1 $d 93-97 $e 20211125 $i 1936-959X $m American journal of neuroradiology $n AJNR Am J Neuroradiol $x MED00009116
- GRA __
- $p CIHR $2 Canada
- LZP __
- $a Pubmed-20220425