-
Something wrong with this record ?
New Porcine Model of Arteriovenous Fistula Documents Increased Coronary Blood Flow at the Cost of Brain Perfusion
A. Valerianova, M. Mlcek, T. Grus, J. Malik, O. Kittnar
Language English Country Switzerland
Document type Journal Article
NLK
Directory of Open Access Journals
from 2010
Free Medical Journals
from 2010
PubMed Central
from 2010
Europe PubMed Central
from 2010
Open Access Digital Library
from 2010-01-01
Open Access Digital Library
from 2010-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2010
- Publication type
- Journal Article MeSH
Background: Arteriovenous fistulas (AVF) represent a low resistant circuit. It is known that their opening leads to decreased systemic vascular resistance, increased cardiac output and other hemodynamic changes. Possible competition of AVF and perfusion of other organs has been observed before, however the specific impact of AVF has not been elucidated yet. Previous animal models studied long-term changes associated with a surgically created high flow AVF. The aim of this study was to create a simple AVF model for the analysis of acute hemodynamic changes. Methods: Domestic female pigs weighing 62.6 ± 5.2 kg were used. All the experiments were held under general anesthesia. The AVF was created using high-diameter ECMO cannulas inserted into femoral artery and vein. Continuous hemodynamic monitoring was performed throughout the protocol. Near-infrared spectroscopy sensors, flow probes and flow wires were inserted to study brain and heart perfusion. Results: AVF blood flow was 2.1 ± 0.5 L/min, which represented around 23% of cardiac output. We observed increase in cardiac output (from 7.02 ± 2.35 L/min to 9.19 ± 2.99 L/min, p = 0.0001) driven dominantly by increased heart rate, increased pulmonary artery pressure, and associated right ventricular work. Coronary artery flow velocity rose. On the contrary, carotid artery flow and brain and muscle tissue oxygenation measured by NIRS decreased significantly. Conclusions: Our new non-surgical AVF model is reproducible and demonstrated an acute decrease of brain and muscle perfusion.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22017292
- 003
- CZ-PrNML
- 005
- 20220720100157.0
- 007
- ta
- 008
- 220718s2022 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3389/fphys.2022.881658 $2 doi
- 035 __
- $a (PubMed)35574433
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Valerianova, Anna $u 3rd Department of Internal Medicine, General University Hospital in Prague, 1st Faculty of Medicine, Charles University, Prague, Czechia $u Institute of Physiology, 1st Faculty of Medicine, Charles University, Prague, Czechia
- 245 10
- $a New Porcine Model of Arteriovenous Fistula Documents Increased Coronary Blood Flow at the Cost of Brain Perfusion / $c A. Valerianova, M. Mlcek, T. Grus, J. Malik, O. Kittnar
- 520 9_
- $a Background: Arteriovenous fistulas (AVF) represent a low resistant circuit. It is known that their opening leads to decreased systemic vascular resistance, increased cardiac output and other hemodynamic changes. Possible competition of AVF and perfusion of other organs has been observed before, however the specific impact of AVF has not been elucidated yet. Previous animal models studied long-term changes associated with a surgically created high flow AVF. The aim of this study was to create a simple AVF model for the analysis of acute hemodynamic changes. Methods: Domestic female pigs weighing 62.6 ± 5.2 kg were used. All the experiments were held under general anesthesia. The AVF was created using high-diameter ECMO cannulas inserted into femoral artery and vein. Continuous hemodynamic monitoring was performed throughout the protocol. Near-infrared spectroscopy sensors, flow probes and flow wires were inserted to study brain and heart perfusion. Results: AVF blood flow was 2.1 ± 0.5 L/min, which represented around 23% of cardiac output. We observed increase in cardiac output (from 7.02 ± 2.35 L/min to 9.19 ± 2.99 L/min, p = 0.0001) driven dominantly by increased heart rate, increased pulmonary artery pressure, and associated right ventricular work. Coronary artery flow velocity rose. On the contrary, carotid artery flow and brain and muscle tissue oxygenation measured by NIRS decreased significantly. Conclusions: Our new non-surgical AVF model is reproducible and demonstrated an acute decrease of brain and muscle perfusion.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Mlcek, Mikulas $u Institute of Physiology, 1st Faculty of Medicine, Charles University, Prague, Czechia
- 700 1_
- $a Grus, Tomas $u 2nd Surgical clinic, Cardiovascular Surgery, General University Hospital in Prague, 1st Faculty of Medicine, Charles University, Prague, Czechia
- 700 1_
- $a Malik, Jan $u 3rd Department of Internal Medicine, General University Hospital in Prague, 1st Faculty of Medicine, Charles University, Prague, Czechia
- 700 1_
- $a Kittnar, Otomar $u Institute of Physiology, 1st Faculty of Medicine, Charles University, Prague, Czechia
- 773 0_
- $w MED00174601 $t Frontiers in physiology $x 1664-042X $g Roč. 13, č. - (2022), s. 881658
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35574433 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20220718 $b ABA008
- 991 __
- $a 20220720100152 $b ABA008
- 999 __
- $a ind $b bmc $g 1816524 $s 1168534
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 13 $c - $d 881658 $e 20220427 $i 1664-042X $m Frontiers in physiology $n Front. physiol. $x MED00174601
- LZP __
- $a Pubmed-20220718