-
Je něco špatně v tomto záznamu ?
Development of a portable hypoxia chamber for ultra-high dose rate laser-driven proton radiobiology applications
P. Chaudhary, DC. Gwynne, B. Odlozilik, A. McMurray, G. Milluzzo, C. Maiorino, D. Doria, H. Ahmed, L. Romagnani, A. Alejo, H. Padda, J. Green, D. Carroll, N. Booth, P. McKenna, S. Kar, G. Petringa, R. Catalano, FP. Cammarata, GAP. Cirrone, SJ....
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články
Grantová podpora
EP/K022415/1
engineering and physical sciences research council
EPJ500094/1
engineering and physical sciences research council
EP/P010059/1
engineering and physical sciences research council
18HLT04 UHD
european metrology programme for innovation and research
European Union's Horizon 2020 research
horizon 2020 framework programme
innovation program under the Marie Sklowdowska-Curie grant agreement no 754507
horizon 2020 framework programme
NLK
BioMedCentral
od 2006-12-01
BioMedCentral Open Access
od 2006
Directory of Open Access Journals
od 2006
Free Medical Journals
od 2006
PubMed Central
od 2006
Europe PubMed Central
od 2006
ProQuest Central
od 2009-01-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-01-01
Health & Medicine (ProQuest)
od 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2006
Springer Nature OA/Free Journals
od 2006-12-01
- MeSH
- DNA účinky záření MeSH
- hypoxie MeSH
- kyslík MeSH
- lasery MeSH
- lidé MeSH
- protony * MeSH
- radiobiologie * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: There is currently significant interest in assessing the role of oxygen in the radiobiological effects at ultra-high dose rates. Oxygen modulation is postulated to play a role in the enhanced sparing effect observed in FLASH radiotherapy, where particles are delivered at 40-1000 Gy/s. Furthermore, the development of laser-driven accelerators now enables radiobiology experiments in extreme regimes where dose rates can exceed 109 Gy/s, and predicted oxygen depletion effects on cellular response can be tested. Access to appropriate experimental enviroments, allowing measurements under controlled oxygenation conditions, is a key requirement for these studies. We report on the development and application of a bespoke portable hypoxia chamber specifically designed for experiments employing laser-driven sources, but also suitable for comparator studies under FLASH and conventional irradiation conditions. MATERIALS AND METHODS: We used oxygen concentration measurements to test the induction of hypoxia and the maintenance capacity of the chambers. Cellular hypoxia induction was verified using hypoxia inducible factor-1α immunostaining. Calibrated radiochromic films and GEANT-4 simulations verified the dosimetry variations inside and outside the chambers. We irradiated hypoxic human skin fibroblasts (AG01522B) cells with laser-driven protons, conventional protons and reference 225 kVp X-rays to quantify DNA DSB damage and repair under hypoxia. We further measured the oxygen enhancement ratio for cell survival after X-ray exposure in normal fibroblast and radioresistant patient- derived GBM stem cells. RESULTS: Oxygen measurements showed that our chambers maintained a radiobiological hypoxic environment for at least 45 min and pathological hypoxia for up to 24 h after disconnecting the chambers from the gas supply. We observed a significant reduction in the 53BP1 foci induced by laser-driven protons, conventional protons and X-rays in the hypoxic cells compared to normoxic cells at 30 min post-irradiation. Under hypoxic irradiations, the Laser-driven protons induced significant residual DNA DSB damage in hypoxic AG01522B cells compared to the conventional dose rate protons suggesting an important impact of these extremely high dose-rate exposures. We obtained an oxygen enhancement ratio (OER) of 2.1 ± 0.1 and 2.5 ± 0.1 respectively for the AG01522B and patient-derived GBM stem cells for X-ray irradiation using our hypoxia chambers. CONCLUSION: We demonstrated the design and application of portable hypoxia chambers for studying cellular radiobiological endpoints after exposure to laser-driven protons at ultra-high dose, conventional protons and X-rays. Suitable levels of reduced oxygen concentration could be maintained in the absence of external gassing to quantify hypoxic effects. The data obtained provided indication of an enhanced residual DNA DSB damage under hypoxic conditions at ultra-high dose rate compared to the conventional protons or X-rays.
Department of Physics SUPA University of Strathclyde Glasgow G1 1XQ Scotland UK
Extreme Light Infrastructure Str Reactorului No 30 077125 Bucharest Magurele Romania
Laboratoire LULI École Polytechnique Route de Saclay 91128 Palaiseau Paris France
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22018773
- 003
- CZ-PrNML
- 005
- 20220804135102.0
- 007
- ta
- 008
- 220720s2022 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s13014-022-02024-3 $2 doi
- 035 __
- $a (PubMed)35428301
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Chaudhary, Pankaj $u The Patrick G. Johnston Centre for Cancer Research, Queen's University Belfast, Lisburn Road, Belfast, BT9 7AE, Northern Ireland, UK. p.chaudhary@qub.ac.uk $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK. p.chaudhary@qub.ac.uk $1 https://orcid.org/0000000203813635
- 245 10
- $a Development of a portable hypoxia chamber for ultra-high dose rate laser-driven proton radiobiology applications / $c P. Chaudhary, DC. Gwynne, B. Odlozilik, A. McMurray, G. Milluzzo, C. Maiorino, D. Doria, H. Ahmed, L. Romagnani, A. Alejo, H. Padda, J. Green, D. Carroll, N. Booth, P. McKenna, S. Kar, G. Petringa, R. Catalano, FP. Cammarata, GAP. Cirrone, SJ. McMahon, KM. Prise, M. Borghesi
- 520 9_
- $a BACKGROUND: There is currently significant interest in assessing the role of oxygen in the radiobiological effects at ultra-high dose rates. Oxygen modulation is postulated to play a role in the enhanced sparing effect observed in FLASH radiotherapy, where particles are delivered at 40-1000 Gy/s. Furthermore, the development of laser-driven accelerators now enables radiobiology experiments in extreme regimes where dose rates can exceed 109 Gy/s, and predicted oxygen depletion effects on cellular response can be tested. Access to appropriate experimental enviroments, allowing measurements under controlled oxygenation conditions, is a key requirement for these studies. We report on the development and application of a bespoke portable hypoxia chamber specifically designed for experiments employing laser-driven sources, but also suitable for comparator studies under FLASH and conventional irradiation conditions. MATERIALS AND METHODS: We used oxygen concentration measurements to test the induction of hypoxia and the maintenance capacity of the chambers. Cellular hypoxia induction was verified using hypoxia inducible factor-1α immunostaining. Calibrated radiochromic films and GEANT-4 simulations verified the dosimetry variations inside and outside the chambers. We irradiated hypoxic human skin fibroblasts (AG01522B) cells with laser-driven protons, conventional protons and reference 225 kVp X-rays to quantify DNA DSB damage and repair under hypoxia. We further measured the oxygen enhancement ratio for cell survival after X-ray exposure in normal fibroblast and radioresistant patient- derived GBM stem cells. RESULTS: Oxygen measurements showed that our chambers maintained a radiobiological hypoxic environment for at least 45 min and pathological hypoxia for up to 24 h after disconnecting the chambers from the gas supply. We observed a significant reduction in the 53BP1 foci induced by laser-driven protons, conventional protons and X-rays in the hypoxic cells compared to normoxic cells at 30 min post-irradiation. Under hypoxic irradiations, the Laser-driven protons induced significant residual DNA DSB damage in hypoxic AG01522B cells compared to the conventional dose rate protons suggesting an important impact of these extremely high dose-rate exposures. We obtained an oxygen enhancement ratio (OER) of 2.1 ± 0.1 and 2.5 ± 0.1 respectively for the AG01522B and patient-derived GBM stem cells for X-ray irradiation using our hypoxia chambers. CONCLUSION: We demonstrated the design and application of portable hypoxia chambers for studying cellular radiobiological endpoints after exposure to laser-driven protons at ultra-high dose, conventional protons and X-rays. Suitable levels of reduced oxygen concentration could be maintained in the absence of external gassing to quantify hypoxic effects. The data obtained provided indication of an enhanced residual DNA DSB damage under hypoxic conditions at ultra-high dose rate compared to the conventional protons or X-rays.
- 650 _2
- $a DNA $x účinky záření $7 D004247
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hypoxie $7 D000860
- 650 _2
- $a lasery $7 D007834
- 650 _2
- $a kyslík $7 D010100
- 650 12
- $a protony $7 D011522
- 650 12
- $a radiobiologie $7 D011853
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Gwynne, Deborah C $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK
- 700 1_
- $a Odlozilik, Boris $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK $u ELI-Beamlines Centre, Institute of Physics, Czech Academy of Sciences, Za Radnicí 835, 252 41, Dolní Břežany, Czech Republic
- 700 1_
- $a McMurray, Aaron $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK
- 700 1_
- $a Milluzzo, Giuliana $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK $u Laboratori Nazionali del Sud - Istituto Nazionale di Fisica Nucleare, Via S Sofia 62, 95123, Catania, Italy
- 700 1_
- $a Maiorino, Carla $u The Patrick G. Johnston Centre for Cancer Research, Queen's University Belfast, Lisburn Road, Belfast, BT9 7AE, Northern Ireland, UK
- 700 1_
- $a Doria, Domenico $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK $u Extreme Light Infrastructure (ELI-NP) and Horia Hulubei National Institute for R & D in Physics and Nuclear Engineering (IFIN-HH), Str. Reactorului No. 30, 077125, Bucharest, Magurele, Romania
- 700 1_
- $a Ahmed, Hamad $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK $u Experimental Science Group, Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxford, OX11 0QX, England, UK
- 700 1_
- $a Romagnani, Lorenzo $u Laboratoire LULI, École Polytechnique, Route de Saclay, 91128, Palaiseau, Paris, France
- 700 1_
- $a Alejo, Aaron $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK
- 700 1_
- $a Padda, Hersimerjit $u Department of Physics, SUPA, University of Strathclyde, Glasgow, G1 1XQ, Scotland, UK
- 700 1_
- $a Green, James $u Experimental Science Group, Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxford, OX11 0QX, England, UK
- 700 1_
- $a Carroll, David $u Experimental Science Group, Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxford, OX11 0QX, England, UK
- 700 1_
- $a Booth, Nicola $u Experimental Science Group, Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxford, OX11 0QX, England, UK
- 700 1_
- $a McKenna, Paul $u Department of Physics, SUPA, University of Strathclyde, Glasgow, G1 1XQ, Scotland, UK
- 700 1_
- $a Kar, Satyabrata $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK
- 700 1_
- $a Petringa, Giada $u Laboratori Nazionali del Sud - Istituto Nazionale di Fisica Nucleare, Via S Sofia 62, 95123, Catania, Italy
- 700 1_
- $a Catalano, Roberto $u Laboratori Nazionali del Sud - Istituto Nazionale di Fisica Nucleare, Via S Sofia 62, 95123, Catania, Italy
- 700 1_
- $a Cammarata, Francesco P $u Laboratori Nazionali del Sud - Istituto Nazionale di Fisica Nucleare, Via S Sofia 62, 95123, Catania, Italy
- 700 1_
- $a Cirrone, Giuseppe A P $u Laboratori Nazionali del Sud - Istituto Nazionale di Fisica Nucleare, Via S Sofia 62, 95123, Catania, Italy
- 700 1_
- $a McMahon, Stephen J $u The Patrick G. Johnston Centre for Cancer Research, Queen's University Belfast, Lisburn Road, Belfast, BT9 7AE, Northern Ireland, UK
- 700 1_
- $a Prise, Kevin M $u The Patrick G. Johnston Centre for Cancer Research, Queen's University Belfast, Lisburn Road, Belfast, BT9 7AE, Northern Ireland, UK. k.prise@qub.ac.uk
- 700 1_
- $a Borghesi, Marco $u Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast, BT7 1NN, Northern Ireland, UK. M.Borghesi@qub.ac.uk
- 773 0_
- $w MED00165460 $t Radiation oncology (London, England) $x 1748-717X $g Roč. 17, č. 1 (2022), s. 77
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35428301 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804135055 $b ABA008
- 999 __
- $a ok $b bmc $g 1822402 $s 1170016
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 17 $c 1 $d 77 $e 20220415 $i 1748-717X $m Radiation oncology $n Radiat. oncol. $x MED00165460
- GRA __
- $a EP/K022415/1 $p engineering and physical sciences research council
- GRA __
- $a EPJ500094/1 $p engineering and physical sciences research council
- GRA __
- $a EP/P010059/1 $p engineering and physical sciences research council
- GRA __
- $a 18HLT04 UHD $p european metrology programme for innovation and research
- GRA __
- $a European Union's Horizon 2020 research $p horizon 2020 framework programme
- GRA __
- $a innovation program under the Marie Sklowdowska-Curie grant agreement no 754507 $p horizon 2020 framework programme
- LZP __
- $a Pubmed-20220720