-
Je něco špatně v tomto záznamu ?
Preparation of Smart Surfaces Based on PNaSS@PEDOT Microspheres: Testing of E. coli Detection
E. Tomšík, S. Laishevkina, J. Svoboda, K. Gunar, J. Hromádková, N. Shevchenko
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
Grantová podpora
NU20-06-00424
Czech Health Research Council
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
35408397
DOI
10.3390/s22072784
Knihovny.cz E-zdroje
- MeSH
- bicyklické sloučeniny heterocyklické chemie MeSH
- Escherichia coli * MeSH
- mikrosféry MeSH
- polymery * chemie MeSH
- Publikační typ
- časopisecké články MeSH
The main task of the research is to acquire fundamental knowledge about the effect of polymer structure on the physicochemical properties of films. A novel meta-material that can be used in manufacturing sensor layers was developed as a model. At the first stage, poly(sodium 4-styrenesulfonate) (PNaSS) cross-linked microspheres are synthesized (which are based on strong polyelectrolytes containing sulfo groups in each monomer unit), and at the second stage, PNaSS@PEDOT microspheres are formed. The poly(3,4-ethylenedioxythiophene) (PEDOT) shell was obtained by the acid-assisted self-polymerization of the monomer; this process is biologically safe and thus suitable for biomedical applications. The suitability of electrochemical impedance spectroscopy for E. coli detection was tested; it was revealed that the attached bacterial wall was destroyed upon application of constant oxidation potential (higher than 0.5 V), which makes the PNaSS@PEDOT microsphere particles promising materials for the development of antifouling coatings. Furthermore, under open-circuit conditions, the walls of E. coli bacteria were not destroyed, which opens up the possibility of employing such meta-materials as sensor films. Scanning electron microscopy, X-ray photoelectron spectroscopy, water contact angle, and wide-angle X-ray diffraction methods were applied in order to characterize the PNaSS@PEDOT films.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22018871
- 003
- CZ-PrNML
- 005
- 20240905081258.0
- 007
- ta
- 008
- 220720s2022 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s22072784 $2 doi
- 035 __
- $a (PubMed)35408397
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Tomšík, Elena $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 162 06 Prague, Czech Republic $1 https://orcid.org/0000000217491091 $7 xx0322157
- 245 10
- $a Preparation of Smart Surfaces Based on PNaSS@PEDOT Microspheres: Testing of E. coli Detection / $c E. Tomšík, S. Laishevkina, J. Svoboda, K. Gunar, J. Hromádková, N. Shevchenko
- 520 9_
- $a The main task of the research is to acquire fundamental knowledge about the effect of polymer structure on the physicochemical properties of films. A novel meta-material that can be used in manufacturing sensor layers was developed as a model. At the first stage, poly(sodium 4-styrenesulfonate) (PNaSS) cross-linked microspheres are synthesized (which are based on strong polyelectrolytes containing sulfo groups in each monomer unit), and at the second stage, PNaSS@PEDOT microspheres are formed. The poly(3,4-ethylenedioxythiophene) (PEDOT) shell was obtained by the acid-assisted self-polymerization of the monomer; this process is biologically safe and thus suitable for biomedical applications. The suitability of electrochemical impedance spectroscopy for E. coli detection was tested; it was revealed that the attached bacterial wall was destroyed upon application of constant oxidation potential (higher than 0.5 V), which makes the PNaSS@PEDOT microsphere particles promising materials for the development of antifouling coatings. Furthermore, under open-circuit conditions, the walls of E. coli bacteria were not destroyed, which opens up the possibility of employing such meta-materials as sensor films. Scanning electron microscopy, X-ray photoelectron spectroscopy, water contact angle, and wide-angle X-ray diffraction methods were applied in order to characterize the PNaSS@PEDOT films.
- 650 _2
- $a bicyklické sloučeniny heterocyklické $x chemie $7 D019086
- 650 12
- $a Escherichia coli $7 D004926
- 650 _2
- $a mikrosféry $7 D008863
- 650 12
- $a polymery $x chemie $7 D011108
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Laishevkina, Svetlana $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 162 06 Prague, Czech Republic $u Institute of Macromolecular Compounds, Russian Academy of Sciences, Bolshoy pr., 31, 199004 Saint-Petersburg, Russia $1 https://orcid.org/000000016796235X
- 700 1_
- $a Svoboda, Jan $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 162 06 Prague, Czech Republic
- 700 1_
- $a Gunar, Kristýna $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 162 06 Prague, Czech Republic
- 700 1_
- $a Hromádková, Jiřina $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 162 06 Prague, Czech Republic
- 700 1_
- $a Shevchenko, Natalia $u Institute of Macromolecular Compounds, Russian Academy of Sciences, Bolshoy pr., 31, 199004 Saint-Petersburg, Russia $1 https://orcid.org/000000017492268X
- 773 0_
- $w MED00008309 $t Sensors $x 1424-8220 $g Roč. 22, č. 7 (2022)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35408397 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20240905081253 $b ABA008
- 999 __
- $a ok $b bmc $g 1822455 $s 1170114
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 22 $c 7 $e 20220405 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- GRA __
- $a NU20-06-00424 $p Czech Health Research Council
- LZP __
- $a Pubmed-20220720