-
Je něco špatně v tomto záznamu ?
Value of Contrast-enhanced Magnetic Resonance Imaging (MRI) in the Diagnosis of Breast Cancer
MA. Gonçalves, BTL. Pereira, CA. Tavares, TMR. Santos, EFF. da Cunha, TC. Ramalho
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, přehledy
Grantová podpora
07837/2014-9
FAPEMIG and CNPq
- MeSH
- kontrastní látky * MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- nádory prsu * diagnostické zobrazování MeSH
- voda MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
This review article aims to address the main features of breast cancer. Thus, the general aspects of this disease have been shown since the first evidence of breast cancer in the world until the numbers today. In this way, there are some ways to prevent breast cancer, such as the woman's lifestyle (healthy eating habits and physical activities) that helps to reduce the incidence of this anomaly. The first noticeable symptom of this anomaly is typically a lump that feels different from the rest of the breast tissue. More than 80% of breast cancer are discovered when the woman feels a lump being present and about 90% of the cases, the cancer is noticed by the woman herself. Currently, the most used method for the detection of cancer and other injuries is the Magnetic Resonance Imaging (MRI) technique. This technique has been shown to be very effective, however, for a better visualization of the images, Contrast Agents (CAs) are used, which are paramagnetic compounds capable of increasing the relaxation of the hydrogen atoms of the water molecules present in the body tissues. The most used CAs are Gd3+ complexes, although they are very efficient, they are toxic to the organism. Thus, new contrast agents have been studied to replace Gd3+ complexes; we can mention iron oxides as a promising substitute.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22019570
- 003
- CZ-PrNML
- 005
- 20220804135759.0
- 007
- ta
- 008
- 220720s2022 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.2174/1389557521666210521113155 $2 doi
- 035 __
- $a (PubMed)34355681
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Gonçalves, Mateus Aquino $u Department of Chemistry, Federal University of Lavras, P.O. Box 3037, Lavras MG 37200-000, Brazil
- 245 10
- $a Value of Contrast-enhanced Magnetic Resonance Imaging (MRI) in the Diagnosis of Breast Cancer / $c MA. Gonçalves, BTL. Pereira, CA. Tavares, TMR. Santos, EFF. da Cunha, TC. Ramalho
- 520 9_
- $a This review article aims to address the main features of breast cancer. Thus, the general aspects of this disease have been shown since the first evidence of breast cancer in the world until the numbers today. In this way, there are some ways to prevent breast cancer, such as the woman's lifestyle (healthy eating habits and physical activities) that helps to reduce the incidence of this anomaly. The first noticeable symptom of this anomaly is typically a lump that feels different from the rest of the breast tissue. More than 80% of breast cancer are discovered when the woman feels a lump being present and about 90% of the cases, the cancer is noticed by the woman herself. Currently, the most used method for the detection of cancer and other injuries is the Magnetic Resonance Imaging (MRI) technique. This technique has been shown to be very effective, however, for a better visualization of the images, Contrast Agents (CAs) are used, which are paramagnetic compounds capable of increasing the relaxation of the hydrogen atoms of the water molecules present in the body tissues. The most used CAs are Gd3+ complexes, although they are very efficient, they are toxic to the organism. Thus, new contrast agents have been studied to replace Gd3+ complexes; we can mention iron oxides as a promising substitute.
- 650 12
- $a nádory prsu $x diagnostické zobrazování $7 D001943
- 650 12
- $a kontrastní látky $7 D003287
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a magnetická rezonanční tomografie $x metody $7 D008279
- 650 _2
- $a voda $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Pereira, Bruna T L $u Department of Chemistry, Federal University of Lavras, P.O. Box 3037, Lavras MG 37200-000, Brazil
- 700 1_
- $a Tavares, Camila A $u Department of Chemistry, Federal University of Lavras, P.O. Box 3037, Lavras MG 37200-000, Brazil
- 700 1_
- $a Santos, Taináh M R $u Department of Chemistry, Federal University of Lavras, P.O. Box 3037, Lavras MG 37200-000, Brazil
- 700 1_
- $a da Cunha, Elaine F F $u Department of Chemistry, Federal University of Lavras, P.O. Box 3037, Lavras MG 37200-000, Brazil
- 700 1_
- $a Ramalho, Teodorico C $u Department of Chemistry, Federal University of Lavras, P.O. Box 3037, Lavras MG 37200-000, Brazil $u Department of Chemistry, Faculty of Science, University of Hradec Kralove, Hradec Kralove, Czech Republic
- 773 0_
- $w MED00008043 $t Mini reviews in medicinal chemistry $x 1875-5607 $g Roč. 22, č. 6 (2022), s. 865-872
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34355681 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804135753 $b ABA008
- 999 __
- $a ok $b bmc $g 1822964 $s 1170813
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 22 $c 6 $d 865-872 $e - $i 1875-5607 $m Mini-reviews in medicinal chemistry $n Mini Rev Med Chem $x MED00008043
- GRA __
- $a 07837/2014-9 $p FAPEMIG and CNPq
- LZP __
- $a Pubmed-20220720