Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

The Anti-Depressive Effects of Ultra-High Static Magnetic Field

Y. Lv, Y. Fan, X. Tian, B. Yu, C. Song, C. Feng, L. Zhang, X. Ji, V. Zablotskii, X. Zhang

. 2022 ; 56 (2) : 354-365. [pub] 20211218

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22025059

BACKGROUND: Ultra-high field magnetic resonance imaging (MRI) has obvious advantages in acquiring high-resolution images. 7 T MRI has been clinically approved and 21.1 T MRI has also been tested on rodents. PURPOSE: To examine the effects of ultra-high field on mice behavior and neuron activity. STUDY TYPE: Prospective, animal model. ANIMAL MODEL: Ninety-eight healthy C57BL/6 mice and 18 depression model mice. FIELD STRENGTH: 11.1-33.0 T SMF (static magnetic field) for 1 hour and 7 T for 8 hours. Gradients were not on and no imaging sequence was used. ASSESSMENT: Open field test, elevated plus maze, three-chambered social test, Morris water maze, tail suspension test, sucrose preference test, blood routine, biochemistry examinations, enzyme-linked immunosorbent assay, immunofluorescent assay. STATISTICAL TESTS: The normality of the data was assessed by Shapiro-Wilk test, followed by Student's t test or the Mann-Whitney U test for statistical significance. The statistical cut-off line is P < 0.05. RESULTS: Compared to the sham group, healthy C57/6 mice spent more time in the center area (35.12 ± 4.034, increased by 47.19%) in open field test and improved novel index (0.6201 ± 0.02522, increased by 16.76%) in three-chambered social test a few weeks after 1 hour 11.1-33.0 T SMF exposure. 7 T SMF exposure for 8 hours alleviated the depression state of depression mice, including less immobile time in tail suspension test (58.32% reduction) and higher sucrose preference (increased by 8.80%). Brain tissue analysis shows that 11.1-33.0 T and 7 T SMFs can increase oxytocin by 164.65% and 36.03%, respectively. Moreover, the c-Fos level in hippocampus region was increased by 14.79%. DATA CONCLUSION: 11.1-33.0 T SMFs exposure for 1 hour or 7 T SMF exposure for 8 hours did not have detrimental effects on healthy or depressed mice. Instead, these ultra-high field SMFs have anti-depressive potentials. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22025059
003      
CZ-PrNML
005      
20221031101347.0
007      
ta
008      
221017s2022 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jmri.28035 $2 doi
035    __
$a (PubMed)34921571
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Lv, Yue $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
245    14
$a The Anti-Depressive Effects of Ultra-High Static Magnetic Field / $c Y. Lv, Y. Fan, X. Tian, B. Yu, C. Song, C. Feng, L. Zhang, X. Ji, V. Zablotskii, X. Zhang
520    9_
$a BACKGROUND: Ultra-high field magnetic resonance imaging (MRI) has obvious advantages in acquiring high-resolution images. 7 T MRI has been clinically approved and 21.1 T MRI has also been tested on rodents. PURPOSE: To examine the effects of ultra-high field on mice behavior and neuron activity. STUDY TYPE: Prospective, animal model. ANIMAL MODEL: Ninety-eight healthy C57BL/6 mice and 18 depression model mice. FIELD STRENGTH: 11.1-33.0 T SMF (static magnetic field) for 1 hour and 7 T for 8 hours. Gradients were not on and no imaging sequence was used. ASSESSMENT: Open field test, elevated plus maze, three-chambered social test, Morris water maze, tail suspension test, sucrose preference test, blood routine, biochemistry examinations, enzyme-linked immunosorbent assay, immunofluorescent assay. STATISTICAL TESTS: The normality of the data was assessed by Shapiro-Wilk test, followed by Student's t test or the Mann-Whitney U test for statistical significance. The statistical cut-off line is P < 0.05. RESULTS: Compared to the sham group, healthy C57/6 mice spent more time in the center area (35.12 ± 4.034, increased by 47.19%) in open field test and improved novel index (0.6201 ± 0.02522, increased by 16.76%) in three-chambered social test a few weeks after 1 hour 11.1-33.0 T SMF exposure. 7 T SMF exposure for 8 hours alleviated the depression state of depression mice, including less immobile time in tail suspension test (58.32% reduction) and higher sucrose preference (increased by 8.80%). Brain tissue analysis shows that 11.1-33.0 T and 7 T SMFs can increase oxytocin by 164.65% and 36.03%, respectively. Moreover, the c-Fos level in hippocampus region was increased by 14.79%. DATA CONCLUSION: 11.1-33.0 T SMFs exposure for 1 hour or 7 T SMF exposure for 8 hours did not have detrimental effects on healthy or depressed mice. Instead, these ultra-high field SMFs have anti-depressive potentials. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
650    _2
$a zvířata $7 D000818
650    _2
$a lidé $7 D006801
650    12
$a magnetické pole $7 D060526
650    12
$a magnetická rezonanční tomografie $7 D008279
650    _2
$a myši $7 D051379
650    _2
$a myši inbrední C57BL $7 D008810
650    _2
$a prospektivní studie $7 D011446
650    _2
$a sacharosa $7 D013395
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Fan, Yixiang $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
700    1_
$a Tian, Xiaofei $u Institutes of Physical Science and Information Technology, Anhui University, Hefei, China
700    1_
$a Yu, Biao $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
700    1_
$a Song, Chao $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
700    1_
$a Feng, Chuanlin $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
700    1_
$a Zhang, Lei $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
700    1_
$a Ji, Xinmiao $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
700    1_
$a Zablotskii, Vitalii $u Institute of Physics, Czech Academy of Sciences, Prague, Czech Republic $u International Magnetobiology Frontier Research Center, Hefei, China
700    1_
$a Zhang, Xin $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China $u Institutes of Physical Science and Information Technology, Anhui University, Hefei, China $u International Magnetobiology Frontier Research Center, Hefei, China $1 https://orcid.org/0000000234992189
773    0_
$w MED00004911 $t Journal of magnetic resonance imaging $x 1522-2586 $g Roč. 56, č. 2 (2022), s. 354-365
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34921571 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20221017 $b ABA008
991    __
$a 20221031101345 $b ABA008
999    __
$a ok $b bmc $g 1854658 $s 1176349
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 56 $c 2 $d 354-365 $e 20211218 $i 1522-2586 $m Journal of magnetic resonance imaging $n J Magn Reson Imaging $x MED00004911
LZP    __
$a Pubmed-20221017

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...