Je něco špatně v tomto záznamu ?
The Anti-Depressive Effects of Ultra-High Static Magnetic Field
Y. Lv, Y. Fan, X. Tian, B. Yu, C. Song, C. Feng, L. Zhang, X. Ji, V. Zablotskii, X. Zhang
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
34921571
DOI
10.1002/jmri.28035
Knihovny.cz E-zdroje
- MeSH
- lidé MeSH
- magnetická rezonanční tomografie * MeSH
- magnetické pole * MeSH
- myši inbrední C57BL MeSH
- myši MeSH
- prospektivní studie MeSH
- sacharosa MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Ultra-high field magnetic resonance imaging (MRI) has obvious advantages in acquiring high-resolution images. 7 T MRI has been clinically approved and 21.1 T MRI has also been tested on rodents. PURPOSE: To examine the effects of ultra-high field on mice behavior and neuron activity. STUDY TYPE: Prospective, animal model. ANIMAL MODEL: Ninety-eight healthy C57BL/6 mice and 18 depression model mice. FIELD STRENGTH: 11.1-33.0 T SMF (static magnetic field) for 1 hour and 7 T for 8 hours. Gradients were not on and no imaging sequence was used. ASSESSMENT: Open field test, elevated plus maze, three-chambered social test, Morris water maze, tail suspension test, sucrose preference test, blood routine, biochemistry examinations, enzyme-linked immunosorbent assay, immunofluorescent assay. STATISTICAL TESTS: The normality of the data was assessed by Shapiro-Wilk test, followed by Student's t test or the Mann-Whitney U test for statistical significance. The statistical cut-off line is P < 0.05. RESULTS: Compared to the sham group, healthy C57/6 mice spent more time in the center area (35.12 ± 4.034, increased by 47.19%) in open field test and improved novel index (0.6201 ± 0.02522, increased by 16.76%) in three-chambered social test a few weeks after 1 hour 11.1-33.0 T SMF exposure. 7 T SMF exposure for 8 hours alleviated the depression state of depression mice, including less immobile time in tail suspension test (58.32% reduction) and higher sucrose preference (increased by 8.80%). Brain tissue analysis shows that 11.1-33.0 T and 7 T SMFs can increase oxytocin by 164.65% and 36.03%, respectively. Moreover, the c-Fos level in hippocampus region was increased by 14.79%. DATA CONCLUSION: 11.1-33.0 T SMFs exposure for 1 hour or 7 T SMF exposure for 8 hours did not have detrimental effects on healthy or depressed mice. Instead, these ultra-high field SMFs have anti-depressive potentials. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
Institute of Physics Czech Academy of Sciences Prague Czech Republic
Institutes of Physical Science and Information Technology Anhui University Hefei China
International Magnetobiology Frontier Research Center Hefei China
Science Island Branch of Graduate School University of Science and Technology of China Hefei China
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22025059
- 003
- CZ-PrNML
- 005
- 20221031101347.0
- 007
- ta
- 008
- 221017s2022 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/jmri.28035 $2 doi
- 035 __
- $a (PubMed)34921571
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Lv, Yue $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
- 245 14
- $a The Anti-Depressive Effects of Ultra-High Static Magnetic Field / $c Y. Lv, Y. Fan, X. Tian, B. Yu, C. Song, C. Feng, L. Zhang, X. Ji, V. Zablotskii, X. Zhang
- 520 9_
- $a BACKGROUND: Ultra-high field magnetic resonance imaging (MRI) has obvious advantages in acquiring high-resolution images. 7 T MRI has been clinically approved and 21.1 T MRI has also been tested on rodents. PURPOSE: To examine the effects of ultra-high field on mice behavior and neuron activity. STUDY TYPE: Prospective, animal model. ANIMAL MODEL: Ninety-eight healthy C57BL/6 mice and 18 depression model mice. FIELD STRENGTH: 11.1-33.0 T SMF (static magnetic field) for 1 hour and 7 T for 8 hours. Gradients were not on and no imaging sequence was used. ASSESSMENT: Open field test, elevated plus maze, three-chambered social test, Morris water maze, tail suspension test, sucrose preference test, blood routine, biochemistry examinations, enzyme-linked immunosorbent assay, immunofluorescent assay. STATISTICAL TESTS: The normality of the data was assessed by Shapiro-Wilk test, followed by Student's t test or the Mann-Whitney U test for statistical significance. The statistical cut-off line is P < 0.05. RESULTS: Compared to the sham group, healthy C57/6 mice spent more time in the center area (35.12 ± 4.034, increased by 47.19%) in open field test and improved novel index (0.6201 ± 0.02522, increased by 16.76%) in three-chambered social test a few weeks after 1 hour 11.1-33.0 T SMF exposure. 7 T SMF exposure for 8 hours alleviated the depression state of depression mice, including less immobile time in tail suspension test (58.32% reduction) and higher sucrose preference (increased by 8.80%). Brain tissue analysis shows that 11.1-33.0 T and 7 T SMFs can increase oxytocin by 164.65% and 36.03%, respectively. Moreover, the c-Fos level in hippocampus region was increased by 14.79%. DATA CONCLUSION: 11.1-33.0 T SMFs exposure for 1 hour or 7 T SMF exposure for 8 hours did not have detrimental effects on healthy or depressed mice. Instead, these ultra-high field SMFs have anti-depressive potentials. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a magnetické pole $7 D060526
- 650 12
- $a magnetická rezonanční tomografie $7 D008279
- 650 _2
- $a myši $7 D051379
- 650 _2
- $a myši inbrední C57BL $7 D008810
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a sacharosa $7 D013395
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Fan, Yixiang $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
- 700 1_
- $a Tian, Xiaofei $u Institutes of Physical Science and Information Technology, Anhui University, Hefei, China
- 700 1_
- $a Yu, Biao $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
- 700 1_
- $a Song, Chao $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
- 700 1_
- $a Feng, Chuanlin $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
- 700 1_
- $a Zhang, Lei $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
- 700 1_
- $a Ji, Xinmiao $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
- 700 1_
- $a Zablotskii, Vitalii $u Institute of Physics, Czech Academy of Sciences, Prague, Czech Republic $u International Magnetobiology Frontier Research Center, Hefei, China
- 700 1_
- $a Zhang, Xin $u High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China $u Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China $u Institutes of Physical Science and Information Technology, Anhui University, Hefei, China $u International Magnetobiology Frontier Research Center, Hefei, China $1 https://orcid.org/0000000234992189
- 773 0_
- $w MED00004911 $t Journal of magnetic resonance imaging $x 1522-2586 $g Roč. 56, č. 2 (2022), s. 354-365
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34921571 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20221017 $b ABA008
- 991 __
- $a 20221031101345 $b ABA008
- 999 __
- $a ok $b bmc $g 1854658 $s 1176349
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 56 $c 2 $d 354-365 $e 20211218 $i 1522-2586 $m Journal of magnetic resonance imaging $n J Magn Reson Imaging $x MED00004911
- LZP __
- $a Pubmed-20221017