Evaluation of Non-Invasive Gargle Lavage Sampling for the Detection of SARS-CoV-2 Using rRT-PCR or Antigen Assay

O. Bouska, H. Jaworek, V. Koudelakova, K. Kubanova, P. Dzubak, R. Slavkovsky, B. Siska, P. Pavlis, J. Vrbkova, M. Hajduch

. 2022 ; 14 (12) : . [pub] 20221219

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22032132

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused considerable disruption worldwide. For efficient SARS-CoV-2 detection, new methods of rapid, non-invasive sampling are needed. This study aimed to investigate the stability of SARS-CoV-2 in a novel medium for gargle-lavage (GL) self-sampling and to compare the performance of SARS-CoV-2 detection in paired self-collected GL and clinician-obtained nasopharyngeal swab (NPS) samples. The stability study for SARS-CoV-2 preservation in a novel medium was performed over 14 days (4 °C, 24-27 °C, and 37 °C). In total, 494 paired GL and NPS samples were obtained at the University Hospital in Olomouc in April 2021. SARS-CoV-2 detection in paired samples was performed with a SARS-CoV-2 Nucleic Acid Detection Kit (Zybio, Chongqing Municipality, Chongqing, China), an Elecsys® SARS-CoV-2 Antigen assay (Roche Diagnostics, Mannheim, Germany), and a SARS-CoV-2 Antigen ELISA (EUROIMMUN, Lübeck, Germany). The stability study demonstrated excellent SARS-CoV-2 preservation in the novel medium for 14 days. SARS-CoV-2 was detected in 55.7% of NPS samples and 55.7% of GL samples using rRT-PCR, with an overall agreement of 91.9%. The positive percent agreement (PPA) of the rRT-PCR in the GL samples was 92.7%, and the negative percent agreement (NPA) was 90.9%, compared with the NPS samples. The PPA of the rRT-PCR in the NPS and GL samples was 93.2% when all positive tests were used as the reference standard. Both antigen detection assays showed poor sensitivity compared to rRT-PCR (33.2% and 36.0%). rRT-PCR SARS-CoV-2 detection in self-collected GL samples had a similar PPA and NPA to that of NPSs. GL self-sampling offers a suitable and more comfortable alternative for SARS-CoV-2 detection.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22032132
003      
CZ-PrNML
005      
20230131151655.0
007      
ta
008      
230120s2022 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/v14122829 $2 doi
035    __
$a (PubMed)36560833
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Bouska, Ondrej $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic
245    10
$a Evaluation of Non-Invasive Gargle Lavage Sampling for the Detection of SARS-CoV-2 Using rRT-PCR or Antigen Assay / $c O. Bouska, H. Jaworek, V. Koudelakova, K. Kubanova, P. Dzubak, R. Slavkovsky, B. Siska, P. Pavlis, J. Vrbkova, M. Hajduch
520    9_
$a Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused considerable disruption worldwide. For efficient SARS-CoV-2 detection, new methods of rapid, non-invasive sampling are needed. This study aimed to investigate the stability of SARS-CoV-2 in a novel medium for gargle-lavage (GL) self-sampling and to compare the performance of SARS-CoV-2 detection in paired self-collected GL and clinician-obtained nasopharyngeal swab (NPS) samples. The stability study for SARS-CoV-2 preservation in a novel medium was performed over 14 days (4 °C, 24-27 °C, and 37 °C). In total, 494 paired GL and NPS samples were obtained at the University Hospital in Olomouc in April 2021. SARS-CoV-2 detection in paired samples was performed with a SARS-CoV-2 Nucleic Acid Detection Kit (Zybio, Chongqing Municipality, Chongqing, China), an Elecsys® SARS-CoV-2 Antigen assay (Roche Diagnostics, Mannheim, Germany), and a SARS-CoV-2 Antigen ELISA (EUROIMMUN, Lübeck, Germany). The stability study demonstrated excellent SARS-CoV-2 preservation in the novel medium for 14 days. SARS-CoV-2 was detected in 55.7% of NPS samples and 55.7% of GL samples using rRT-PCR, with an overall agreement of 91.9%. The positive percent agreement (PPA) of the rRT-PCR in the GL samples was 92.7%, and the negative percent agreement (NPA) was 90.9%, compared with the NPS samples. The PPA of the rRT-PCR in the NPS and GL samples was 93.2% when all positive tests were used as the reference standard. Both antigen detection assays showed poor sensitivity compared to rRT-PCR (33.2% and 36.0%). rRT-PCR SARS-CoV-2 detection in self-collected GL samples had a similar PPA and NPA to that of NPSs. GL self-sampling offers a suitable and more comfortable alternative for SARS-CoV-2 detection.
650    _2
$a lidé $7 D006801
650    12
$a SARS-CoV-2 $x genetika $7 D000086402
650    12
$a COVID-19 $x diagnóza $7 D000086382
650    _2
$a léčebná irigace $7 D007507
650    _2
$a polymerázová řetězová reakce s reverzní transkripcí $7 D020133
650    _2
$a testování na COVID-19 $7 D000086742
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a nazofarynx $7 D009305
655    _2
$a časopisecké články $7 D016428
700    1_
$a Jaworek, Hana $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic $u Laboratory of Experimental Medicine, University Hospital Olomouc, 775 15 Olomouc, Czech Republic
700    1_
$a Koudelakova, Vladimira $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic $u Laboratory of Experimental Medicine, University Hospital Olomouc, 775 15 Olomouc, Czech Republic $1 https://orcid.org/0000000158427478
700    1_
$a Kubanova, Katerina $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic
700    1_
$a Dzubak, Petr $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic $u Laboratory of Experimental Medicine, University Hospital Olomouc, 775 15 Olomouc, Czech Republic $u Cancer Research Czech Republic, 779 00 Olomouc, Czech Republic $1 https://orcid.org/0000000230985969
700    1_
$a Slavkovsky, Rastislav $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic
700    1_
$a Siska, Branislav $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic
700    1_
$a Pavlis, Petr $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic
700    1_
$a Vrbkova, Jana $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic
700    1_
$a Hajduch, Marian $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, 779 00 Olomouc, Czech Republic $u Laboratory of Experimental Medicine, University Hospital Olomouc, 775 15 Olomouc, Czech Republic $u Cancer Research Czech Republic, 779 00 Olomouc, Czech Republic $1 https://orcid.org/000000024834908X
773    0_
$w MED00177099 $t Viruses $x 1999-4915 $g Roč. 14, č. 12 (2022)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36560833 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230120 $b ABA008
991    __
$a 20230131151650 $b ABA008
999    __
$a ok $b bmc $g 1891105 $s 1183467
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2022 $b 14 $c 12 $e 20221219 $i 1999-4915 $m Viruses $n Viruses $x MED00177099
LZP    __
$a Pubmed-20230120

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...