Wireless Monitoring of Gastrointestinal Transit Time, Intra-luminal pH, Pressure and Temperature in Experimental Pigs: A Pilot Study

J. Bureš, V. Radochová, J. Květina, D. Kohoutová, M. Vališ, S. Rejchrt, J. Žďárová Karasová, O. Soukup, Š. Suchánek, M. Zavoral

. 2023 ; 66 (1) : 11-18. [pub] -

Language English Country Czech Republic

Document type Journal Article

Grant support
00179906 Ministerstvo Zdravotnictví Ceské Republiky

BACKGROUND: There is no single gold standard for investigation of gastrointestinal motility function. Wireless motility monitoring involves a novel concept which provides a complex information on gastrointestinal function (gastrointestinal transit time, intra-luminal pH, pressure and temperature). Gastrointestinal motility functions of experimental pigs are very similar to those of humans. That is why porcine studies have already provided suitable experimental models for several preclinical projects. AIMS: The aim of our study was to adopt methods of non-invasive wireless monitoring of gastrointestinal functions in experimental pigs. METHODS: Five experimental adult female pigs were enrolled into the study. Wireless motility capsules were delivered into the porcine stomach endoscopically. Gastrointestinal transit and intra-luminal conditions were recorded for five days. RESULTS: Records of animals provided good (3 pigs) or very good quality files (2 pigs). 31150 variables were evaluated. Mean time of the presence of capsules in the stomach was 926 ± 295 min, transfer of a capsule from the stomach into the duodenum lasted 5-34 min. Mean small intestinal transit time was 251 ± 43 min. Food intake was associated with an increase of gastric luminal temperature and a decrease of intra-gastric pressure. The highest intra-luminal pH was present in the ileum. The highest temperature and the lowest intra-luminal pressure were found in the colon. All data displayed a substantial inter-individual variability. CONCLUSIONS: This pilot study has proven that a long-term function monitoring of the gastrointestinal tract by means of wireless motility capsules in experimental pigs is feasible. However, both ketamine-based induction of general anaesthesia as well as long-lasting general anaesthesia (> 6 hours) should be avoided to prevent retention of a capsule in the porcine stomach.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23008960
003      
CZ-PrNML
005      
20230802075156.0
007      
ta
008      
230707s2023 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14712/18059694.2023.9 $2 doi
035    __
$a (PubMed)37384804
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Bureš, Jan, $u Biomedical Research Centre, University Hospital Hradec Králové, Czech Republic $u Department of Medicine, Charles University, First Faculty of Medicine, Praha and Military University Hospital Praha, Czech Republic $u Institute of Gastrointestinal Oncology, Military University Hospital Praha, Czech Republic $d 1954- $7 nlk19990073060
245    10
$a Wireless Monitoring of Gastrointestinal Transit Time, Intra-luminal pH, Pressure and Temperature in Experimental Pigs: A Pilot Study / $c J. Bureš, V. Radochová, J. Květina, D. Kohoutová, M. Vališ, S. Rejchrt, J. Žďárová Karasová, O. Soukup, Š. Suchánek, M. Zavoral
520    9_
$a BACKGROUND: There is no single gold standard for investigation of gastrointestinal motility function. Wireless motility monitoring involves a novel concept which provides a complex information on gastrointestinal function (gastrointestinal transit time, intra-luminal pH, pressure and temperature). Gastrointestinal motility functions of experimental pigs are very similar to those of humans. That is why porcine studies have already provided suitable experimental models for several preclinical projects. AIMS: The aim of our study was to adopt methods of non-invasive wireless monitoring of gastrointestinal functions in experimental pigs. METHODS: Five experimental adult female pigs were enrolled into the study. Wireless motility capsules were delivered into the porcine stomach endoscopically. Gastrointestinal transit and intra-luminal conditions were recorded for five days. RESULTS: Records of animals provided good (3 pigs) or very good quality files (2 pigs). 31150 variables were evaluated. Mean time of the presence of capsules in the stomach was 926 ± 295 min, transfer of a capsule from the stomach into the duodenum lasted 5-34 min. Mean small intestinal transit time was 251 ± 43 min. Food intake was associated with an increase of gastric luminal temperature and a decrease of intra-gastric pressure. The highest intra-luminal pH was present in the ileum. The highest temperature and the lowest intra-luminal pressure were found in the colon. All data displayed a substantial inter-individual variability. CONCLUSIONS: This pilot study has proven that a long-term function monitoring of the gastrointestinal tract by means of wireless motility capsules in experimental pigs is feasible. However, both ketamine-based induction of general anaesthesia as well as long-lasting general anaesthesia (> 6 hours) should be avoided to prevent retention of a capsule in the porcine stomach.
650    _2
$a dospělí $7 D000328
650    _2
$a lidé $7 D006801
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a zvířata $7 D000818
650    _2
$a prasata $7 D013552
650    _2
$a teplota $7 D013696
650    _2
$a pilotní projekty $7 D010865
650    _2
$a tobolky $7 D002214
650    12
$a gastrointestinální průchod $7 D005772
650    _2
$a koncentrace vodíkových iontů $7 D006863
655    _2
$a časopisecké články $7 D016428
700    1_
$a Radochová, Věra $u Animal Laboratory, University of Defence, Faculty of Military Health Sciences, Hradec Králové, Czech Republic $7 xx0258128
700    1_
$a Květina, Jaroslav, $u Biomedical Research Centre, University Hospital Hradec Králové, Czech Republic $d 1930-2022 $7 jk01071205
700    1_
$a Kohoutová, Darina, $u Biomedical Research Centre, University Hospital Hradec Králové, Czech Republic $u The Royal Marsden Hospital NHS Foundation Trust, London, United Kingdom $d 1980- $7 mzk2013797579
700    1_
$a Vališ, Martin, $u Department of Neurology, Charles University, Faculty of Medicine in Hradec Králové and University Hospital Hradec Králové, Czech Republic $d 1973- $7 xx0107109
700    1_
$a Rejchrt, Stanislav, $u 2nd Department of Medicine - Gastroenterology, Charles University, Faculty of Medicine in Hradec Králové and University Hospital Hradec Králové, Czech Republic $d 1963- $7 mzk2005306779
700    1_
$a Žďárová Karasová, Jana, $u Department of Toxicology and Military Pharmacy, University of Defence, Faculty of Military Health Sciences, Hradec Králové, Czech Republic $d 1982- $7 xx0099787
700    1_
$a Soukup, Ondřej $u Biomedical Research Centre, University Hospital Hradec Králové, Czech Republic $7 xx0253350
700    1_
$a Suchánek, Štěpán $u Department of Medicine, Charles University, First Faculty of Medicine, Praha and Military University Hospital Praha, Czech Republic $u Institute of Gastrointestinal Oncology, Military University Hospital Praha, Czech Republic $7 xx0105313
700    1_
$a Zavoral, Miroslav, $u Department of Medicine, Charles University, First Faculty of Medicine, Praha and Military University Hospital Praha, Czech Republic $u Institute of Gastrointestinal Oncology, Military University Hospital Praha, Czech Republic $d 1953- $7 xx0036686
773    0_
$w MED00010947 $t Acta medica (Hradec Kralove) $x 1805-9694 $g Roč. 66, č. 1 (2023), s. 11-18
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37384804 $y Pubmed
910    __
$a ABA008 $b A 3077 $c 1072 $y p $z 0
990    __
$a 20230707 $b ABA008
991    __
$a 20230802075152 $b ABA008
999    __
$a ok $b bmc $g 1964378 $s 1195223
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 66 $c 1 $d 11-18 $e - $i 1805-9694 $m Acta Medica $n Acta Med. (Hradec Král.) $x MED00010947
GRA    __
$a 00179906 $p Ministerstvo Zdravotnictví Ceské Republiky
LZP    __
$b NLK198 $a Pubmed-20230707

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...