Comparison of semi-quantitative and visual assessment of early MRI signal evolution in acute ischaemic stroke
J. Civrny, Z. Sedlackova, T. Malenak, P. Kucera, D. Machal, M. Kocher, D. Sanak, T. Furst, M. Cerna
Status neindexováno Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2014
Free Medical Journals
od 2014
PubMed Central
od 2014
Europe PubMed Central
od 2014
Open Access Digital Library
od 2014-01-01
Open Access Digital Library
od 2014-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2014
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The evaluation of DWI/FLAIR mismatch in ischaemic stroke patients with unknown, time from onset can determine the treatment strategy. This approach is based on, visual assessment and may be subject to insufficient inter-rater agreement. OBJECTIVE: To compare the inter-rater agreement of visual evaluation of FLAIR MRI and proposed region of interest (ROI) semiquantitative method in large vessel occlusion (LVO) strokes. METHODS: Five readers have analysed MRIs of 104 patients obtained within six hours of the onset of stroke symptoms resulting from LVO visually and semi-quantitatively. For the semiquantitative analysis, a ROI method was used to obtain relative signal intensity compared to the unaffected side. Cut-off values of 1.15 and 1.10 were tested. The analysis yielded FLAIR-positive (abnormal) and negative (normal) findings. Percentage agreement and Fleiss kappa coefficients were calculated. RESULTS: The visual agreement of 5/5 readers and ≥ 4/5 readers occurred in 31% and 59% of cases respectively. Semi-quantitative evaluation using a cut-off value of 1.15 increased the agreements to 67% and 88% respectively. The agreement of visual evaluation was fair. The semi-quantitative method utilising the cut-off of 1.15 had moderate agreement although it increased the number of FLAIR-negative results compared to the visual evaluation. A low cut-off value of 1.10 didn't improve the agreement significantly. CONCLUSION: The inter-rater agreement of visual evaluation of FLAIR in patients with short-duration large vessel occlusion stroke was fair. The high cut-off value of semiquantitative evaluation increased the agreement although it changed the proportion of FLAIR positive and negative results.
Department of Neurology Palacky University and University Hospital Olomouc Czech Republic
Department of Radiology Palacky University and University Hospital Olomouc Czech Republic
Faculty of Health Sciences Palacky University Olomouc Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23009913
- 003
- CZ-PrNML
- 005
- 20250716134108.0
- 007
- ta
- 008
- 230707e20230425enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ejro.2023.100488 $2 doi
- 035 __
- $a (PubMed)37168316
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Civrny, J $u Department of Radiology, Palacky University and University Hospital, Olomouc, Czech Republic $u Faculty of Health Sciences, Palacky University, Olomouc, Czech Republic
- 245 10
- $a Comparison of semi-quantitative and visual assessment of early MRI signal evolution in acute ischaemic stroke / $c J. Civrny, Z. Sedlackova, T. Malenak, P. Kucera, D. Machal, M. Kocher, D. Sanak, T. Furst, M. Cerna
- 520 9_
- $a BACKGROUND: The evaluation of DWI/FLAIR mismatch in ischaemic stroke patients with unknown, time from onset can determine the treatment strategy. This approach is based on, visual assessment and may be subject to insufficient inter-rater agreement. OBJECTIVE: To compare the inter-rater agreement of visual evaluation of FLAIR MRI and proposed region of interest (ROI) semiquantitative method in large vessel occlusion (LVO) strokes. METHODS: Five readers have analysed MRIs of 104 patients obtained within six hours of the onset of stroke symptoms resulting from LVO visually and semi-quantitatively. For the semiquantitative analysis, a ROI method was used to obtain relative signal intensity compared to the unaffected side. Cut-off values of 1.15 and 1.10 were tested. The analysis yielded FLAIR-positive (abnormal) and negative (normal) findings. Percentage agreement and Fleiss kappa coefficients were calculated. RESULTS: The visual agreement of 5/5 readers and ≥ 4/5 readers occurred in 31% and 59% of cases respectively. Semi-quantitative evaluation using a cut-off value of 1.15 increased the agreements to 67% and 88% respectively. The agreement of visual evaluation was fair. The semi-quantitative method utilising the cut-off of 1.15 had moderate agreement although it increased the number of FLAIR-negative results compared to the visual evaluation. A low cut-off value of 1.10 didn't improve the agreement significantly. CONCLUSION: The inter-rater agreement of visual evaluation of FLAIR in patients with short-duration large vessel occlusion stroke was fair. The high cut-off value of semiquantitative evaluation increased the agreement although it changed the proportion of FLAIR positive and negative results.
- 590 __
- $a NEINDEXOVÁNO
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Sedlackova, Z $u Department of Radiology, Palacky University and University Hospital, Olomouc, Czech Republic $u Faculty of Health Sciences, Palacky University, Olomouc, Czech Republic
- 700 1_
- $a Maleňák, Tomáš $u Department of Radiology, Palacky University and University Hospital, Olomouc, Czech Republic $7 xx0334064
- 700 1_
- $a Kucera, P $u Department of Radiology, Palacky University and University Hospital, Olomouc, Czech Republic
- 700 1_
- $a Machal, D $u Department of Radiology, Palacky University and University Hospital, Olomouc, Czech Republic
- 700 1_
- $a Kocher, M $u Department of Radiology, Palacky University and University Hospital, Olomouc, Czech Republic
- 700 1_
- $a Sanak, D $u Department of Neurology, Palacky University and University Hospital, Olomouc, Czech Republic
- 700 1_
- $a Furst, T $u Department of Mathematical Analysis and Applications of Mathematics, Faculty of Science, Palacky University Olomouc, Czech Republic
- 700 1_
- $a Cerna, M $u Department of Radiology, Palacky University and University Hospital, Olomouc, Czech Republic
- 773 0_
- $w MED00211266 $t European journal of radiology open $x 2352-0477 $g Roč. 10 (20230425), s. 100488
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37168316 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20230707 $b ABA008
- 991 __
- $a 20250716134050 $b ABA008
- 999 __
- $a ok $b bmc $g 1958557 $s 1196177
- BAS __
- $a 3
- BAS __
- $a PreBMC-PubMed-not-MEDLINE
- BMC __
- $a 2023 $b 10 $c - $d 100488 $e 20230425 $i 2352-0477 $m European journal of radiology open $n Eur J Radiol Open $x MED00211266
- LZP __
- $a Pubmed-20230707