• Something wrong with this record ?

Diagnostic accuracy of Tensiomyography parameters for monitoring peripheral neuromuscular fatigue

M. Kalc, K. Puš, A. Paravlic, J. Urbanc, B. Šimunič

. 2023 ; 70 (-) : 102775. [pub] 20230411

Language English Country England, Great Britain

Document type Journal Article

The diagnostic accuracy of tensiomyography (TMG) parameters compared to the gold standard in neuromuscular fatigue evaluation using voluntary and electrically induced muscle activation is unclear. This study aimed to investigate the diagnostic accuracy of TMG parameters to detect individual changes after interventions that were designed to induce central or peripheral fatigue. Nineteen males (age: 32.2 ± 9.3 years) performed two interventions, consisting of maintaining 25% of maximal voluntary contraction (MViC25%) and a 30 s all-out cycling test (Wingate), respectively. TMG parameters, maximum voluntary contraction (PtMViC), voluntary activation (VA%) and electrically elicited double twitches (Dtw) were assessed on the knee extensors before (PRE), one minute (POST) and seven minutes after (POST7) the intervention. The diagnostic accuracy (AUC) of TMG parameters were evaluated in comparison to two criteria measures (PtMViC and Dtw). RM ANOVA revealed a significant interaction between the effects of intervention and time on VA% (p = 0.001) and Dtw (p < 0.001) but not for PtMViC (p = 0.420). AUC showed that TMG parameters had a good ability in detecting muscular fatigue assessed by Dtw but not by PtMViC. The results of the current study suggest that TMG parameters can be used to monitor peripheral neuromuscular fatigue.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23011205
003      
CZ-PrNML
005      
20230801132856.0
007      
ta
008      
230718s2023 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jelekin.2023.102775 $2 doi
035    __
$a (PubMed)37068408
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Kalc, Miloš $u University of Maribor, Faculty of Medicine, Institute of Sports Medicine, Maribor, Slovenia; Science and Research Centre Koper, Institute for Kinesiology Research, Koper, Slovenia. Electronic address: milos.kalc@um.si
245    10
$a Diagnostic accuracy of Tensiomyography parameters for monitoring peripheral neuromuscular fatigue / $c M. Kalc, K. Puš, A. Paravlic, J. Urbanc, B. Šimunič
520    9_
$a The diagnostic accuracy of tensiomyography (TMG) parameters compared to the gold standard in neuromuscular fatigue evaluation using voluntary and electrically induced muscle activation is unclear. This study aimed to investigate the diagnostic accuracy of TMG parameters to detect individual changes after interventions that were designed to induce central or peripheral fatigue. Nineteen males (age: 32.2 ± 9.3 years) performed two interventions, consisting of maintaining 25% of maximal voluntary contraction (MViC25%) and a 30 s all-out cycling test (Wingate), respectively. TMG parameters, maximum voluntary contraction (PtMViC), voluntary activation (VA%) and electrically elicited double twitches (Dtw) were assessed on the knee extensors before (PRE), one minute (POST) and seven minutes after (POST7) the intervention. The diagnostic accuracy (AUC) of TMG parameters were evaluated in comparison to two criteria measures (PtMViC and Dtw). RM ANOVA revealed a significant interaction between the effects of intervention and time on VA% (p = 0.001) and Dtw (p < 0.001) but not for PtMViC (p = 0.420). AUC showed that TMG parameters had a good ability in detecting muscular fatigue assessed by Dtw but not by PtMViC. The results of the current study suggest that TMG parameters can be used to monitor peripheral neuromuscular fatigue.
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé $7 D006801
650    _2
$a mladý dospělý $7 D055815
650    _2
$a dospělí $7 D000328
650    12
$a svalová únava $x fyziologie $7 D018763
650    12
$a kosterní svaly $x fyziologie $7 D018482
650    _2
$a koleno $x fyziologie $7 D007717
650    _2
$a dolní končetina $7 D035002
650    _2
$a kolenní kloub $x fyziologie $7 D007719
650    _2
$a svalová kontrakce $x fyziologie $7 D009119
650    _2
$a elektromyografie $7 D004576
655    _2
$a časopisecké články $7 D016428
700    1_
$a Puš, Katarina $u Science and Research Centre Koper, Institute for Kinesiology Research, Koper, Slovenia; University of Ljubljana, Faculty of Sport, Ljubljana, Slovenia; Department of Health Sciences, Alma Mater Europaea - ECM, Maribor, Slovenia
700    1_
$a Paravlic, Armin $u Science and Research Centre Koper, Institute for Kinesiology Research, Koper, Slovenia; University of Ljubljana, Faculty of Sport, Ljubljana, Slovenia; Faculty of Sports Studies, Masaryk University, Brno, Czech Republic
700    1_
$a Urbanc, Jure $u Science and Research Centre Koper, Institute for Kinesiology Research, Koper, Slovenia
700    1_
$a Šimunič, Boštjan $u Science and Research Centre Koper, Institute for Kinesiology Research, Koper, Slovenia
773    0_
$w MED00002646 $t Journal of electromyography and kinesiology $x 1873-5711 $g Roč. 70, č. - (2023), s. 102775
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37068408 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230718 $b ABA008
991    __
$a 20230801132853 $b ABA008
999    __
$a ok $b bmc $g 1963539 $s 1197470
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 70 $c - $d 102775 $e 20230411 $i 1873-5711 $m Journal of electromyography and kinesiology $n J Electromyogr Kinesiol $x MED00002646
LZP    __
$a Pubmed-20230718

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...