Something wrong with this record ?
Novel stereological method for estimation of cell counts in 3D collagen scaffolds
A. Zavadakova, L. Vistejnova, T. Belinova, F. Tichanek, D. Bilikova, PR. Mouton
Language English Country England, Great Britain
Document type Journal Article, Research Support, U.S. Gov't, Non-P.H.S., Research Support, Non-U.S. Gov't
NLK
Directory of Open Access Journals
from 2011
Free Medical Journals
from 2011
Nature Open Access
from 2011-12-01
PubMed Central
from 2011
Europe PubMed Central
from 2011
ProQuest Central
from 2011-01-01
Open Access Digital Library
from 2011-01-01
Open Access Digital Library
from 2011-01-01
Health & Medicine (ProQuest)
from 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2011
Springer Nature OA/Free Journals
from 2011-12-01
- MeSH
- Collagen * MeSH
- Humans MeSH
- Cell Count methods MeSH
- Cell Proliferation MeSH
- Tissue Engineering MeSH
- Tissue Scaffolds * MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Research Support, U.S. Gov't, Non-P.H.S. MeSH
Current methods for assessing cell proliferation in 3D scaffolds rely on changes in metabolic activity or total DNA, however, direct quantification of cell number in 3D scaffolds remains a challenge. To address this issue, we developed an unbiased stereology approach that uses systematic-random sampling and thin focal-plane optical sectioning of the scaffolds followed by estimation of total cell number (StereoCount). This approach was validated against an indirect method for measuring the total DNA (DNA content); and the Bürker counting chamber, the current reference method for quantifying cell number. We assessed the total cell number for cell seeding density (cells per unit volume) across four values and compared the methods in terms of accuracy, ease-of-use and time demands. The accuracy of StereoCount markedly outperformed the DNA content for cases with ~ 10,000 and ~ 125,000 cells/scaffold. For cases with ~ 250,000 and ~ 375,000 cells/scaffold both StereoCount and DNA content showed lower accuracy than the Bürker but did not differ from each other. In terms of ease-of-use, there was a strong advantage for the StereoCount due to output in terms of absolute cell numbers along with the possibility for an overview of cell distribution and future use of automation for high throughput analysis. Taking together, the StereoCount method is an efficient approach for direct cell quantification in 3D collagen scaffolds. Its major benefit is that automated StereoCount could accelerate research using 3D scaffolds focused on drug discovery for a wide variety of human diseases.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23011420
- 003
- CZ-PrNML
- 005
- 20250819101035.0
- 007
- ta
- 008
- 230718s2023 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-023-35162-z $2 doi
- 035 __
- $a (PubMed)37198326
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Zavadakova, Anna $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Pilsen, Czech Republic. anna.zavadakova@gmail.com
- 245 10
- $a Novel stereological method for estimation of cell counts in 3D collagen scaffolds / $c A. Zavadakova, L. Vistejnova, T. Belinova, F. Tichanek, D. Bilikova, PR. Mouton
- 520 9_
- $a Current methods for assessing cell proliferation in 3D scaffolds rely on changes in metabolic activity or total DNA, however, direct quantification of cell number in 3D scaffolds remains a challenge. To address this issue, we developed an unbiased stereology approach that uses systematic-random sampling and thin focal-plane optical sectioning of the scaffolds followed by estimation of total cell number (StereoCount). This approach was validated against an indirect method for measuring the total DNA (DNA content); and the Bürker counting chamber, the current reference method for quantifying cell number. We assessed the total cell number for cell seeding density (cells per unit volume) across four values and compared the methods in terms of accuracy, ease-of-use and time demands. The accuracy of StereoCount markedly outperformed the DNA content for cases with ~ 10,000 and ~ 125,000 cells/scaffold. For cases with ~ 250,000 and ~ 375,000 cells/scaffold both StereoCount and DNA content showed lower accuracy than the Bürker but did not differ from each other. In terms of ease-of-use, there was a strong advantage for the StereoCount due to output in terms of absolute cell numbers along with the possibility for an overview of cell distribution and future use of automation for high throughput analysis. Taking together, the StereoCount method is an efficient approach for direct cell quantification in 3D collagen scaffolds. Its major benefit is that automated StereoCount could accelerate research using 3D scaffolds focused on drug discovery for a wide variety of human diseases.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a kolagen $7 D003094
- 650 _2
- $a počet buněk $x metody $7 D002452
- 650 12
- $a tkáňové podpůrné struktury $7 D054457
- 650 _2
- $a tkáňové inženýrství $7 D023822
- 650 _2
- $a proliferace buněk $7 D049109
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a Research Support, U.S. Gov't, Non-P.H.S. $7 D013486
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vistejnova, Lucie $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Pilsen, Czech Republic $u Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Pilsen, Czech Republic
- 700 1_
- $a Belinova, Tereza $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Pilsen, Czech Republic $u Imaging and Optics Facility, Institute of Science and Technology Austria, Am Campus 1, Klosterneuburg, Austria
- 700 1_
- $a Tichánek, Filip $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Pilsen, Czech Republic $u Department of Pathological Physiology, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Pilsen, Czech Republic $7 xx0334827
- 700 1_
- $a Bilikova, Dagmar $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 76, Pilsen, Czech Republic
- 700 1_
- $a Mouton, Peter R $u Department of Computer Sciences and Engineering, College of Engineering, University of South Florida, 4202 E Fowler Ave, Tampa, FL, USA $u SRC Biosciences, 1810 W. Kennedy Blvd, Tampa, FL, USA
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 13, č. 1 (2023), s. 7959
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37198326 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20230718 $b ABA008
- 991 __
- $a 20250819101017 $b ABA008
- 999 __
- $a ok $b bmc $g 1963685 $s 1197685
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 13 $c 1 $d 7959 $e 20230517 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20230718