Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Comparative analysis of retinal photoplethysmographic spatial maps and thickness of retinal nerve fiber layer

J. Odstrcilik, R. Kolar, F. Horn, RP. Tornow

. 2023 ; 18 (5) : e0284743. [pub] 20230505

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc23011481

The paper presents a comparative study of the pulsatile attenuation amplitude (PAA) within the optic nerve head (ONH) at four different areas calculated from retinal video sequences and its relevance to the retinal nerve fiber layer thickness (RNFL) changes in normal subjects and patients with different stages of glaucoma. The proposed methodology utilizes processing of retinal video sequences acquired by a novel video ophthalmoscope. The PAA parameter measures the amplitude of heartbeat-modulated light attenuation in retinal tissue. Correlation analysis between PAA and RNFL is performed in vessel-free locations of the peripapillary region with the proposed evaluating patterns: 360° circular area, temporal semi-circle, nasal semi-circle. For comparison, the full ONH area is also included. Various positions and sizes of evaluating patterns in peripapillary region were tested which resulted in different outputs of correlation analysis. The results show significant correlation between PAA and RNFL thickness calculated in proposed areas. The highest correlation coefficient Rtemp = 0.557 (p<0.001) reflects the highest PAA-RNFL correspondence in the temporal semi-circular area, compared to the lowest value in the nasal semi-circular area (Rnasal = 0.332, p<0.001). Furthermore, the results indicate the most relevant approach to calculate PAA from the acquired video sequences is using a thin annulus near the ONH center. Finally, the paper shows the proposed photoplethysmographic principle based on innovative video ophthalmoscope can be used to analyze changes in retinal perfusion in peripapillary area and can be potentially used to assess progression of the RNFL deterioration.

000      
00000naa a2200000 a 4500
001      
bmc23011481
003      
CZ-PrNML
005      
20230801133058.0
007      
ta
008      
230718s2023 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1371/journal.pone.0284743 $2 doi
035    __
$a (PubMed)37146019
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Odstrcilik, Jan $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic $1 https://orcid.org/0000000170536183
245    10
$a Comparative analysis of retinal photoplethysmographic spatial maps and thickness of retinal nerve fiber layer / $c J. Odstrcilik, R. Kolar, F. Horn, RP. Tornow
520    9_
$a The paper presents a comparative study of the pulsatile attenuation amplitude (PAA) within the optic nerve head (ONH) at four different areas calculated from retinal video sequences and its relevance to the retinal nerve fiber layer thickness (RNFL) changes in normal subjects and patients with different stages of glaucoma. The proposed methodology utilizes processing of retinal video sequences acquired by a novel video ophthalmoscope. The PAA parameter measures the amplitude of heartbeat-modulated light attenuation in retinal tissue. Correlation analysis between PAA and RNFL is performed in vessel-free locations of the peripapillary region with the proposed evaluating patterns: 360° circular area, temporal semi-circle, nasal semi-circle. For comparison, the full ONH area is also included. Various positions and sizes of evaluating patterns in peripapillary region were tested which resulted in different outputs of correlation analysis. The results show significant correlation between PAA and RNFL thickness calculated in proposed areas. The highest correlation coefficient Rtemp = 0.557 (p<0.001) reflects the highest PAA-RNFL correspondence in the temporal semi-circular area, compared to the lowest value in the nasal semi-circular area (Rnasal = 0.332, p<0.001). Furthermore, the results indicate the most relevant approach to calculate PAA from the acquired video sequences is using a thin annulus near the ONH center. Finally, the paper shows the proposed photoplethysmographic principle based on innovative video ophthalmoscope can be used to analyze changes in retinal perfusion in peripapillary area and can be potentially used to assess progression of the RNFL deterioration.
650    _2
$a lidé $7 D006801
650    _2
$a nervová vlákna $7 D009412
650    _2
$a retinální gangliové buňky $7 D012165
650    12
$a discus nervi optici $7 D009898
650    12
$a glaukom $x diagnóza $7 D005901
650    _2
$a optická koherentní tomografie $x metody $7 D041623
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Kolar, Radim $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
700    1_
$a Horn, Folkert $u Department of Ophthalmology, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany
700    1_
$a Tornow, Ralf-Peter $u Department of Ophthalmology, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen, Germany
773    0_
$w MED00180950 $t PloS one $x 1932-6203 $g Roč. 18, č. 5 (2023), s. e0284743
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37146019 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230718 $b ABA008
991    __
$a 20230801133054 $b ABA008
999    __
$a ok $b bmc $g 1963723 $s 1197746
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 18 $c 5 $d e0284743 $e 20230505 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
LZP    __
$a Pubmed-20230718

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...