Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis
P. Matlak, H. Brozmanova, P. Sistik, I. Kacirova, P. Hradilek, M. Grundmann
Language English Country England, Great Britain
Document type Journal Article
- MeSH
- Chromatography, Liquid methods MeSH
- Antibodies, Monoclonal, Humanized therapeutic use MeSH
- Humans MeSH
- Natalizumab therapeutic use MeSH
- Peptides therapeutic use MeSH
- Multiple Sclerosis * drug therapy MeSH
- Tandem Mass Spectrometry methods MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
Natalizumab is a humanized recombinant monoclonal IgG4 antibody used in the treatment of multiple sclerosis. Commonly used methods for natalizumab and anti-natalizumab antibodies quantification are enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay, respectively. Measurement of therapeutic monoclonal antibodies can be challenging due to the resemblance to human plasma immunoglobulins. Recent developments in mass spectrometry enables to analyze vast variety of large protein molecules. The aim of this study was to develop a LC-MS/MS method for determining natalizumab in human serum and cerebrospinal fluid (CSF) and apply it to clinical settings. For successful quantification, it was necessary to find specific sequences of peptides in natalizumab. This immunoglobulin was treated with dithiothreitol and iodoacetamide, cleaved with trypsin into short specific peptides and determined on a UPLC-MS/MS system. An Acquity UPLC BEH C18 column at 55 °C and gradient elution was used for analysis. Intra- and interassay accuracies and precisions were tested at four concentration levels. Precision was determined by coefficients of variation and was in the range of 0.8-10.2 %, with accuracy in the range of 89.8-106.4 %. The concentration of natalizumab in patient samples ranged from 1.8 to 193.3 μg/mL. The method was validated according to the European Medicines Agency (EMA) guideline, met all acceptance criteria for accuracy and precision, and is suitable for clinical applications. In comparison to immunoassay, which can be elevated by cross-reaction with endogenous immunoglobulins, the results of developed LC-MS/MS method are more accurate and specific.
Clinic of Neurology Faculty of Medicine University of Ostrava Ostrava Czech Republic
Clinic of Neurology University Hospital Ostrava Ostrava Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23016200
- 003
- CZ-PrNML
- 005
- 20231026110210.0
- 007
- ta
- 008
- 231013s2023 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jpba.2023.115542 $2 doi
- 035 __
- $a (PubMed)37364452
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Matlak, Patrik $u Department of Clinical Neurosciences, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic; Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic
- 245 10
- $a Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis / $c P. Matlak, H. Brozmanova, P. Sistik, I. Kacirova, P. Hradilek, M. Grundmann
- 520 9_
- $a Natalizumab is a humanized recombinant monoclonal IgG4 antibody used in the treatment of multiple sclerosis. Commonly used methods for natalizumab and anti-natalizumab antibodies quantification are enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay, respectively. Measurement of therapeutic monoclonal antibodies can be challenging due to the resemblance to human plasma immunoglobulins. Recent developments in mass spectrometry enables to analyze vast variety of large protein molecules. The aim of this study was to develop a LC-MS/MS method for determining natalizumab in human serum and cerebrospinal fluid (CSF) and apply it to clinical settings. For successful quantification, it was necessary to find specific sequences of peptides in natalizumab. This immunoglobulin was treated with dithiothreitol and iodoacetamide, cleaved with trypsin into short specific peptides and determined on a UPLC-MS/MS system. An Acquity UPLC BEH C18 column at 55 °C and gradient elution was used for analysis. Intra- and interassay accuracies and precisions were tested at four concentration levels. Precision was determined by coefficients of variation and was in the range of 0.8-10.2 %, with accuracy in the range of 89.8-106.4 %. The concentration of natalizumab in patient samples ranged from 1.8 to 193.3 μg/mL. The method was validated according to the European Medicines Agency (EMA) guideline, met all acceptance criteria for accuracy and precision, and is suitable for clinical applications. In comparison to immunoassay, which can be elevated by cross-reaction with endogenous immunoglobulins, the results of developed LC-MS/MS method are more accurate and specific.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a natalizumab $x terapeutické užití $7 D000069442
- 650 _2
- $a chromatografie kapalinová $x metody $7 D002853
- 650 12
- $a roztroušená skleróza $x farmakoterapie $7 D009103
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 650 _2
- $a humanizované monoklonální protilátky $x terapeutické užití $7 D061067
- 650 _2
- $a peptidy $x terapeutické užití $7 D010455
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Brozmanova, Hana $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
- 700 1_
- $a Sistik, Pavel $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic. Electronic address: pavel.sistik@fno.cz
- 700 1_
- $a Kacirova, Ivana $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
- 700 1_
- $a Hradilek, Pavel $u Clinic of Neurology, Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic; Clinic of Neurology, University Hospital Ostrava, Ostrava, Czech Republic
- 700 1_
- $a Grundmann, Milan $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
- 773 0_
- $w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 234, č. - (2023), s. 115542
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37364452 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20231013 $b ABA008
- 991 __
- $a 20231026110203 $b ABA008
- 999 __
- $a ok $b bmc $g 1999994 $s 1202562
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 234 $c - $d 115542 $e 20230622 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
- LZP __
- $a Pubmed-20231013