Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis

P. Matlak, H. Brozmanova, P. Sistik, I. Kacirova, P. Hradilek, M. Grundmann

. 2023 ; 234 (-) : 115542. [pub] 20230622

Language English Country England, Great Britain

Document type Journal Article

Natalizumab is a humanized recombinant monoclonal IgG4 antibody used in the treatment of multiple sclerosis. Commonly used methods for natalizumab and anti-natalizumab antibodies quantification are enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay, respectively. Measurement of therapeutic monoclonal antibodies can be challenging due to the resemblance to human plasma immunoglobulins. Recent developments in mass spectrometry enables to analyze vast variety of large protein molecules. The aim of this study was to develop a LC-MS/MS method for determining natalizumab in human serum and cerebrospinal fluid (CSF) and apply it to clinical settings. For successful quantification, it was necessary to find specific sequences of peptides in natalizumab. This immunoglobulin was treated with dithiothreitol and iodoacetamide, cleaved with trypsin into short specific peptides and determined on a UPLC-MS/MS system. An Acquity UPLC BEH C18 column at 55 °C and gradient elution was used for analysis. Intra- and interassay accuracies and precisions were tested at four concentration levels. Precision was determined by coefficients of variation and was in the range of 0.8-10.2 %, with accuracy in the range of 89.8-106.4 %. The concentration of natalizumab in patient samples ranged from 1.8 to 193.3 μg/mL. The method was validated according to the European Medicines Agency (EMA) guideline, met all acceptance criteria for accuracy and precision, and is suitable for clinical applications. In comparison to immunoassay, which can be elevated by cross-reaction with endogenous immunoglobulins, the results of developed LC-MS/MS method are more accurate and specific.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23016200
003      
CZ-PrNML
005      
20231026110210.0
007      
ta
008      
231013s2023 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jpba.2023.115542 $2 doi
035    __
$a (PubMed)37364452
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Matlak, Patrik $u Department of Clinical Neurosciences, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic; Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic
245    10
$a Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis / $c P. Matlak, H. Brozmanova, P. Sistik, I. Kacirova, P. Hradilek, M. Grundmann
520    9_
$a Natalizumab is a humanized recombinant monoclonal IgG4 antibody used in the treatment of multiple sclerosis. Commonly used methods for natalizumab and anti-natalizumab antibodies quantification are enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay, respectively. Measurement of therapeutic monoclonal antibodies can be challenging due to the resemblance to human plasma immunoglobulins. Recent developments in mass spectrometry enables to analyze vast variety of large protein molecules. The aim of this study was to develop a LC-MS/MS method for determining natalizumab in human serum and cerebrospinal fluid (CSF) and apply it to clinical settings. For successful quantification, it was necessary to find specific sequences of peptides in natalizumab. This immunoglobulin was treated with dithiothreitol and iodoacetamide, cleaved with trypsin into short specific peptides and determined on a UPLC-MS/MS system. An Acquity UPLC BEH C18 column at 55 °C and gradient elution was used for analysis. Intra- and interassay accuracies and precisions were tested at four concentration levels. Precision was determined by coefficients of variation and was in the range of 0.8-10.2 %, with accuracy in the range of 89.8-106.4 %. The concentration of natalizumab in patient samples ranged from 1.8 to 193.3 μg/mL. The method was validated according to the European Medicines Agency (EMA) guideline, met all acceptance criteria for accuracy and precision, and is suitable for clinical applications. In comparison to immunoassay, which can be elevated by cross-reaction with endogenous immunoglobulins, the results of developed LC-MS/MS method are more accurate and specific.
650    _2
$a lidé $7 D006801
650    _2
$a natalizumab $x terapeutické užití $7 D000069442
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    12
$a roztroušená skleróza $x farmakoterapie $7 D009103
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
650    _2
$a humanizované monoklonální protilátky $x terapeutické užití $7 D061067
650    _2
$a peptidy $x terapeutické užití $7 D010455
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
655    _2
$a časopisecké články $7 D016428
700    1_
$a Brozmanova, Hana $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
700    1_
$a Sistik, Pavel $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic. Electronic address: pavel.sistik@fno.cz
700    1_
$a Kacirova, Ivana $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
700    1_
$a Hradilek, Pavel $u Clinic of Neurology, Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic; Clinic of Neurology, University Hospital Ostrava, Ostrava, Czech Republic
700    1_
$a Grundmann, Milan $u Department of Clinical Pharmacology, Institute of Laboratory Medicine, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic; Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 234, č. - (2023), s. 115542
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37364452 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20231013 $b ABA008
991    __
$a 20231026110203 $b ABA008
999    __
$a ok $b bmc $g 1999994 $s 1202562
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 234 $c - $d 115542 $e 20230622 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
LZP    __
$a Pubmed-20231013

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...