• Je něco špatně v tomto záznamu ?

Determination of Corneal Power after Refractive Surgery with Excimer Laser: A Concise Review

V. Galvis, A. Tello, V. Otoya, S. Arba-Mosquera, SJ. Villamizar, A. Translateur, R. Morales

. 2023 ; 79 (5) : 215-220.

Jazyk angličtina Země Česko

Typ dokumentu přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc23019341

Refractive surgery with excimer laser has been a very common surgical procedure worldwide during the last decades. Currently, patients who underwent refractive surgery years ago are older, with a growing number of them now needing cataract surgery. To establish the power of the intraocular lens to be implanted in these patients, it is essential to define the true corneal power. However, since the refractive surgery modified the anterior, but not the posterior surface of the cornea, the determination of the corneal power in this group of patients is challenging. This article reviews the different sources of error in finding the true corneal power in these cases, and comments on several approaches, including the clinical history method as described originally by Holladay, and a modified version of it, as well as new alternatives based on corneal tomography, using devices that are able to measure the actual anterior and posterior corneal curvatures, which have emerged in recent years to address this issue.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23019341
003      
CZ-PrNML
005      
20240105105800.0
007      
ta
008      
231130s2023 xr adc f 000 0|eng||
009      
AR
024    7_
$a 10.31348/2023/8 $2 doi
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Galvis, V. $u Ophthalmology Foundation of Santander - Carlos Ardila Lulle (FOSCAL), Floridablanca, Colombia $u Department of Ophthalmology, Autonomous University of Bucaramanga (UNAB), Bucaramanga, Colombia $u Virgilio Galvis Eye Centre, Floridablanca, Santander, Colombia
245    10
$a Determination of Corneal Power after Refractive Surgery with Excimer Laser: A Concise Review / $c V. Galvis, A. Tello, V. Otoya, S. Arba-Mosquera, SJ. Villamizar, A. Translateur, R. Morales
520    9_
$a Refractive surgery with excimer laser has been a very common surgical procedure worldwide during the last decades. Currently, patients who underwent refractive surgery years ago are older, with a growing number of them now needing cataract surgery. To establish the power of the intraocular lens to be implanted in these patients, it is essential to define the true corneal power. However, since the refractive surgery modified the anterior, but not the posterior surface of the cornea, the determination of the corneal power in this group of patients is challenging. This article reviews the different sources of error in finding the true corneal power in these cases, and comments on several approaches, including the clinical history method as described originally by Holladay, and a modified version of it, as well as new alternatives based on corneal tomography, using devices that are able to measure the actual anterior and posterior corneal curvatures, which have emerged in recent years to address this issue.
650    _7
$a lidé $7 D006801 $2 czmesh
650    _7
$a rohovková topografie $x metody $7 D019781 $2 czmesh
650    _7
$a rohovka $x chirurgie $7 D003315 $2 czmesh
650    17
$a laserová modelace rohovky pod rohovkovou lamelou $7 D020731 $2 czmesh
650    _7
$a lasery excimerové $7 D054018 $2 czmesh
650    17
$a refrakce oka $7 D012029 $2 czmesh
655    _7
$a přehledy $7 D016454 $2 czmesh
700    1_
$a Tello, A. $u Ophthalmology Foundation of Santander - Carlos Ardila Lulle (FOSCAL), Floridablanca, Colombia $u Department of Ophthalmology, Autonomous University of Bucaramanga (UNAB), Bucaramanga, Colombia $u Virgilio Galvis Eye Centre, Floridablanca, Santander, Colombia $u Department of Ophthalmology, Industrial University of Santander (UIS), Bucaramanga, Colombia
700    1_
$a Otoya, V. $u Department of Ophthalmology, Autonomous University of Bucaramanga (UNAB), Bucaramanga, Colombia $u Virgilio Galvis Eye Centre, Floridablanca, Santander, Colombia
700    1_
$a Arba-Mosquera, S. $u SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany
700    1_
$a Villamizar, S. J. $u Department of Ophthalmology, Autonomous University of Bucaramanga (UNAB), Bucaramanga, Colombia
700    1_
$a Translateur, A. $u Department of Ophthalmology, Autonomous University of Bucaramanga (UNAB), Bucaramanga, Colombia $u Virgilio Galvis Eye Centre, Floridablanca, Santander, Colombia
700    1_
$a Morales, R. $u SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany
773    0_
$w MED00010980 $t Česká a slovenská oftalmologie $x 1211-9059 $g Roč. 79, č. 5 (2023), s. 215-220
856    41
$u https://www.prolekare.cz/casopisy/ceska-slovenska-oftalmologie/2023-5-8/determination-of-corneal-power-after-refractive-surgery-with-excimer-laser-a-concise-review-135687 $y plný text volně dostupný
910    __
$a ABA008 $b A 202 $c 639 $y p $z 0
990    __
$a 20231130 $b ABA008
991    __
$a 20240105105753 $b ABA008
999    __
$a ok $b bmc $g 2019937 $s 1205756
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2023 $b 79 $c 5 $d 215-220 $i 1211-9059 $m Česká a slovenská oftalmologie $x MED00010980 $y 135687
LZP    __
$c NLK109 $d 20240105 $b NLK111 $a Meditorial-20231130

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...