Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

History of blood pressure measurement in newborns and infants

K. Javorka

. 2023 ; 72 (5) : 543-555. [pub] 2023Nov28

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc23020565

The development of methods for measuring blood pressure (BP) in newborns and small children has a rich history. Methods for BP measuring in adults had to be adapted to this age group. For measuring BP in direct invasive way, a suitable approach had to be found to access the arterial circulation through the umbilical and later radialis artery. Currently, results obtained from direct invasive BP measurement are considered the "gold standard". The development of non-invasive methods for BP measuring in newborns and children began with the use of von Basch's sphygmomanometer (1880). In 1899, Gustav Gärtner constructed the device, which was the basis for the flush method. After the discovery of the palpation and auscultation methods, these methods were also used for BP measurement in newborns and children, however, the BP values obtained in these ways were typically underestimated using excessively wide cuffs. From the auscultation method, methods utilizing ultrasound and infrasound to detect arterial wall movement and blood flow were later developed. The oscillometric method for BP measurement was introduced by E. J. Marey so early as in 1876. In 1912, P. Balard used the oscillometric technique to measure blood pressure in a large group of newborns. Through different types of oscillometers using various methods for detecting vascular oscillations (such as xylol method, impedance and volume plethysmography, etc.), the development has continued to assessment of vascular oscillations by modern sensor technology and software. For continuous non-invasive blood pressure measurement, the volume-clamp method, first described by Jan Peňáz in 1968, was developed. After modification for use in newborns, application of the cuff to the wrist instead of the finger, it is primarily used in clinical physiological studies to evaluate beat-to-beat BP and heart rate pressure variability, such as in the determination of the baroreflex sensitivity.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23020565
003      
CZ-PrNML
005      
20250502123750.0
007      
ta
008      
231215s2023 xr f 000 0|eng||
009      
AR
024    7_
$a 10.33549/physiolres.935173 $2 doi
035    __
$a (PubMed)38015754
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Javorka, Kamil, $u Department of Physiology, Jessenius Faculty of Medicine, Comenius University, Martin, Slovak Republic. kamil.javorka@uniba.sk $d 1944- $7 mzk2004236812
245    10
$a History of blood pressure measurement in newborns and infants / $c K. Javorka
520    9_
$a The development of methods for measuring blood pressure (BP) in newborns and small children has a rich history. Methods for BP measuring in adults had to be adapted to this age group. For measuring BP in direct invasive way, a suitable approach had to be found to access the arterial circulation through the umbilical and later radialis artery. Currently, results obtained from direct invasive BP measurement are considered the "gold standard". The development of non-invasive methods for BP measuring in newborns and children began with the use of von Basch's sphygmomanometer (1880). In 1899, Gustav Gärtner constructed the device, which was the basis for the flush method. After the discovery of the palpation and auscultation methods, these methods were also used for BP measurement in newborns and children, however, the BP values obtained in these ways were typically underestimated using excessively wide cuffs. From the auscultation method, methods utilizing ultrasound and infrasound to detect arterial wall movement and blood flow were later developed. The oscillometric method for BP measurement was introduced by E. J. Marey so early as in 1876. In 1912, P. Balard used the oscillometric technique to measure blood pressure in a large group of newborns. Through different types of oscillometers using various methods for detecting vascular oscillations (such as xylol method, impedance and volume plethysmography, etc.), the development has continued to assessment of vascular oscillations by modern sensor technology and software. For continuous non-invasive blood pressure measurement, the volume-clamp method, first described by Jan Peňáz in 1968, was developed. After modification for use in newborns, application of the cuff to the wrist instead of the finger, it is primarily used in clinical physiological studies to evaluate beat-to-beat BP and heart rate pressure variability, such as in the determination of the baroreflex sensitivity.
650    _2
$a dospělí $7 D000328
650    _2
$a dítě $7 D002648
650    _2
$a lidé $7 D006801
650    _2
$a novorozenec $7 D007231
650    _2
$a kojenec $7 D007223
650    _2
$a krevní tlak $7 D001794
650    12
$a měření krevního tlaku $x metody $7 D001795
650    12
$a arteriální tlak $7 D062186
650    _2
$a arterie $7 D001158
650    _2
$a prsty ruky $7 D005385
655    _2
$a časopisecké články $7 D016428
773    0_
$w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 72, č. 5 (2023), s. 543-555
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38015754 $y Pubmed
910    __
$a ABA008 $b A 4120 $c 266 $y p $z 0
990    __
$a 20231215 $b ABA008
991    __
$a 20250502123742 $b ABA008
999    __
$a ok $b bmc $g 2255297 $s 1207004
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 72 $c 5 $d 543-555 $e 2023Nov28 $i 1802-9973 $m Physiological research $n Physiol Res $x MED00003824
LZP    __
$b NLK116 $a Pubmed-20231215

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...