-
Something wrong with this record ?
History of blood pressure measurement in newborns and infants
K. Javorka
Language English Country Czech Republic
Document type Journal Article
NLK
Directory of Open Access Journals
from 1991
Free Medical Journals
from 1998
PubMed Central
from 2020
ProQuest Central
from 2005-01-01
Medline Complete (EBSCOhost)
from 2006-01-01
Nursing & Allied Health Database (ProQuest)
from 2005-01-01
Health & Medicine (ProQuest)
from 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1998
- MeSH
- Arterial Pressure * MeSH
- Arteries MeSH
- Child MeSH
- Adult MeSH
- Infant MeSH
- Blood Pressure MeSH
- Humans MeSH
- Blood Pressure Determination * methods MeSH
- Infant, Newborn MeSH
- Fingers MeSH
- Check Tag
- Child MeSH
- Adult MeSH
- Infant MeSH
- Humans MeSH
- Infant, Newborn MeSH
- Publication type
- Journal Article MeSH
The development of methods for measuring blood pressure (BP) in newborns and small children has a rich history. Methods for BP measuring in adults had to be adapted to this age group. For measuring BP in direct invasive way, a suitable approach had to be found to access the arterial circulation through the umbilical and later radialis artery. Currently, results obtained from direct invasive BP measurement are considered the "gold standard". The development of non-invasive methods for BP measuring in newborns and children began with the use of von Basch's sphygmomanometer (1880). In 1899, Gustav Gärtner constructed the device, which was the basis for the flush method. After the discovery of the palpation and auscultation methods, these methods were also used for BP measurement in newborns and children, however, the BP values obtained in these ways were typically underestimated using excessively wide cuffs. From the auscultation method, methods utilizing ultrasound and infrasound to detect arterial wall movement and blood flow were later developed. The oscillometric method for BP measurement was introduced by E. J. Marey so early as in 1876. In 1912, P. Balard used the oscillometric technique to measure blood pressure in a large group of newborns. Through different types of oscillometers using various methods for detecting vascular oscillations (such as xylol method, impedance and volume plethysmography, etc.), the development has continued to assessment of vascular oscillations by modern sensor technology and software. For continuous non-invasive blood pressure measurement, the volume-clamp method, first described by Jan Peňáz in 1968, was developed. After modification for use in newborns, application of the cuff to the wrist instead of the finger, it is primarily used in clinical physiological studies to evaluate beat-to-beat BP and heart rate pressure variability, such as in the determination of the baroreflex sensitivity.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23020565
- 003
- CZ-PrNML
- 005
- 20250502123750.0
- 007
- ta
- 008
- 231215s2023 xr f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.935173 $2 doi
- 035 __
- $a (PubMed)38015754
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Javorka, Kamil, $u Department of Physiology, Jessenius Faculty of Medicine, Comenius University, Martin, Slovak Republic. kamil.javorka@uniba.sk $d 1944- $7 mzk2004236812
- 245 10
- $a History of blood pressure measurement in newborns and infants / $c K. Javorka
- 520 9_
- $a The development of methods for measuring blood pressure (BP) in newborns and small children has a rich history. Methods for BP measuring in adults had to be adapted to this age group. For measuring BP in direct invasive way, a suitable approach had to be found to access the arterial circulation through the umbilical and later radialis artery. Currently, results obtained from direct invasive BP measurement are considered the "gold standard". The development of non-invasive methods for BP measuring in newborns and children began with the use of von Basch's sphygmomanometer (1880). In 1899, Gustav Gärtner constructed the device, which was the basis for the flush method. After the discovery of the palpation and auscultation methods, these methods were also used for BP measurement in newborns and children, however, the BP values obtained in these ways were typically underestimated using excessively wide cuffs. From the auscultation method, methods utilizing ultrasound and infrasound to detect arterial wall movement and blood flow were later developed. The oscillometric method for BP measurement was introduced by E. J. Marey so early as in 1876. In 1912, P. Balard used the oscillometric technique to measure blood pressure in a large group of newborns. Through different types of oscillometers using various methods for detecting vascular oscillations (such as xylol method, impedance and volume plethysmography, etc.), the development has continued to assessment of vascular oscillations by modern sensor technology and software. For continuous non-invasive blood pressure measurement, the volume-clamp method, first described by Jan Peňáz in 1968, was developed. After modification for use in newborns, application of the cuff to the wrist instead of the finger, it is primarily used in clinical physiological studies to evaluate beat-to-beat BP and heart rate pressure variability, such as in the determination of the baroreflex sensitivity.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a novorozenec $7 D007231
- 650 _2
- $a kojenec $7 D007223
- 650 _2
- $a krevní tlak $7 D001794
- 650 12
- $a měření krevního tlaku $x metody $7 D001795
- 650 12
- $a arteriální tlak $7 D062186
- 650 _2
- $a arterie $7 D001158
- 650 _2
- $a prsty ruky $7 D005385
- 655 _2
- $a časopisecké články $7 D016428
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 72, č. 5 (2023), s. 543-555
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38015754 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y p $z 0
- 990 __
- $a 20231215 $b ABA008
- 991 __
- $a 20250502123742 $b ABA008
- 999 __
- $a ok $b bmc $g 2255297 $s 1207004
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 72 $c 5 $d 543-555 $e 2023Nov28 $i 1802-9973 $m Physiological research $n Physiol Res $x MED00003824
- LZP __
- $b NLK116 $a Pubmed-20231215