-
Something wrong with this record ?
Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of 'ground truth'
VY. Reddy, MH. Kong, J. Petru, A. Maan, M. Funasako, K. Minami, P. Ruppersberg, S. Dukkipati, P. Neuzil
Language English Country England, Great Britain
Document type Journal Article
Grant support
Ablacon
NLK
Free Medical Journals
from 1999 to 1 year ago
PubMed Central
from 2008
Open Access Digital Library
from 1999-01-01
Medline Complete (EBSCOhost)
from 1999-01-01
Oxford Journals Open Access Collection
from 1999-01-01
- MeSH
- Epidermal Growth Factor MeSH
- Atrial Fibrillation * diagnosis surgery MeSH
- Catheter Ablation * methods MeSH
- Humans MeSH
- Reproducibility of Results MeSH
- Heart Atria MeSH
- Pulmonary Veins * surgery MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
AIMS: Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility. METHODS AND RESULTS: In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF. CONCLUSION: Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.
Ablacon Inc Wheat Ridge CO USA
Department of Cardiology Homolka Hospital Roentgenova 37 2 Prague 5 Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24000748
- 003
- CZ-PrNML
- 005
- 20240213093342.0
- 007
- ta
- 008
- 240109s2023 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/europace/euad308 $2 doi
- 035 __
- $a (PubMed)37956309
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Reddy, Vivek Y $u Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, PO Box 1030, NewYork, NY 10029, USA $u Department of Cardiology, Homolka Hospital, Roentgenova 37/2, Prague 5, Czech Republic $1 https://orcid.org/0000000256384993
- 245 10
- $a Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of 'ground truth' / $c VY. Reddy, MH. Kong, J. Petru, A. Maan, M. Funasako, K. Minami, P. Ruppersberg, S. Dukkipati, P. Neuzil
- 520 9_
- $a AIMS: Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility. METHODS AND RESULTS: In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF. CONCLUSION: Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a fibrilace síní $x diagnóza $x chirurgie $7 D001281
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a epidermální růstový faktor $7 D004815
- 650 12
- $a katetrizační ablace $x metody $7 D017115
- 650 _2
- $a srdeční síně $7 D006325
- 650 12
- $a venae pulmonales $x chirurgie $7 D011667
- 650 _2
- $a výsledek terapie $7 D016896
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kong, Melissa H $u Ablacon Inc.,Wheat Ridge, CO, USA $1 https://orcid.org/0000000171405935
- 700 1_
- $a Petru, Jan $u Department of Cardiology, Homolka Hospital, Roentgenova 37/2, Prague 5, Czech Republic
- 700 1_
- $a Maan, Abhishek $u Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, PO Box 1030, NewYork, NY 10029, USA
- 700 1_
- $a Funasako, Moritoshi $u Department of Cardiology, Homolka Hospital, Roentgenova 37/2, Prague 5, Czech Republic $1 https://orcid.org/0000000216203924
- 700 1_
- $a Minami, Kentaro $u Department of Cardiology, Homolka Hospital, Roentgenova 37/2, Prague 5, Czech Republic $1 https://orcid.org/0000000200710673
- 700 1_
- $a Ruppersberg, Peter $u Ablacon Inc.,Wheat Ridge, CO, USA $1 https://orcid.org/0000000246121778
- 700 1_
- $a Dukkipati, Srinivas $u Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, PO Box 1030, NewYork, NY 10029, USA
- 700 1_
- $a Neuzil, Petr $u Department of Cardiology, Homolka Hospital, Roentgenova 37/2, Prague 5, Czech Republic $1 https://orcid.org/0000000343348165
- 773 0_
- $w MED00149837 $t Europace $x 1532-2092 $g Roč. 25, č. 11 (2023)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37956309 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240109 $b ABA008
- 991 __
- $a 20240213093339 $b ABA008
- 999 __
- $a ok $b bmc $g 2049398 $s 1210442
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 25 $c 11 $e 2023Nov02 $i 1532-2092 $m Europace $n Europace $x MED00149837
- GRA __
- $p Ablacon
- LZP __
- $a Pubmed-20240109