Ambient ionization mass spectrometry provides screening of selective androgen receptor modulators

A. Nemeškalová, J. Konvalinková, M. Vágnerová, M. Kuchař, J. Buček, V. Vrkoslav, D. Sýkora, J. Cvačka, M. Volny

. 2024 ; 277 (-) : 126358. [pub] 20240606

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24019148

Ambient ionization mass spectrometry allows for analysis of samples in their natural state, i.e., with no sample pre-treatment. It can be viewed as a fast, simple, and economical analysis, but its main disadvantages include a lower analytical performance due to the presence of complex sample matrix and the lack of chromatographic separation prior to the introduction of the sample into the mass spectrometer. Here we present an application of two ambient ionization mass spectrometry techniques, i.e., Desorption Atmospheric Pressure Photoionization and Dielectric Barrier Discharge Ionization, for the analysis of known Selective Androgen Receptor Modulators, which represent common compounds of abuse in professional and semiprofessional sport. Eight real samples of illegal food supplements, seized by the local law enforcement, were used to test the performance of the ambient mass spectrometry and the results were validated against a newly developed targeted LC-UV-MS/MS method performed in multiple reaction monitoring mode with an external calibration for each analyte. In order to decide whether or not the compound can be declared as present, we proposed a system of rules for the interpretation of the obtained spectra. The criteria are based on mass spectrum matching (5-10 ppm accuracy from the theoretical exact mass and a correct isotopic pattern), duration of the mass signal (three or five consecutive scans, depending on the instrumentation used), and intensity above the background noise (threefold increase in intensity and absolute intensity above 5E4 or 1E5, depending on the instrumentation). When applying these criteria, good agreement was found between the tested methods. Ambient ionization techniques were effective at detecting SARMs at pharmacologically relevant doses, i.e., approximately above 1 mg per capsule, although they may fail to detect lower levels or isomeric species. It is demonstrated that when adhering to a set of clear and consistent rules, ambient mass spectrometry can be employed as a qualitative technique for the screening of illegal SARMs with sufficient confidence and without the necessity to perform a regular LC-MS analysis.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24019148
003      
CZ-PrNML
005      
20241024111711.0
007      
ta
008      
241015e20240606ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2024.126358 $2 doi
035    __
$a (PubMed)38879944
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Nemeškalová, Alžběta $u Department of Analytical Chemistry, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic
245    10
$a Ambient ionization mass spectrometry provides screening of selective androgen receptor modulators / $c A. Nemeškalová, J. Konvalinková, M. Vágnerová, M. Kuchař, J. Buček, V. Vrkoslav, D. Sýkora, J. Cvačka, M. Volny
520    9_
$a Ambient ionization mass spectrometry allows for analysis of samples in their natural state, i.e., with no sample pre-treatment. It can be viewed as a fast, simple, and economical analysis, but its main disadvantages include a lower analytical performance due to the presence of complex sample matrix and the lack of chromatographic separation prior to the introduction of the sample into the mass spectrometer. Here we present an application of two ambient ionization mass spectrometry techniques, i.e., Desorption Atmospheric Pressure Photoionization and Dielectric Barrier Discharge Ionization, for the analysis of known Selective Androgen Receptor Modulators, which represent common compounds of abuse in professional and semiprofessional sport. Eight real samples of illegal food supplements, seized by the local law enforcement, were used to test the performance of the ambient mass spectrometry and the results were validated against a newly developed targeted LC-UV-MS/MS method performed in multiple reaction monitoring mode with an external calibration for each analyte. In order to decide whether or not the compound can be declared as present, we proposed a system of rules for the interpretation of the obtained spectra. The criteria are based on mass spectrum matching (5-10 ppm accuracy from the theoretical exact mass and a correct isotopic pattern), duration of the mass signal (three or five consecutive scans, depending on the instrumentation used), and intensity above the background noise (threefold increase in intensity and absolute intensity above 5E4 or 1E5, depending on the instrumentation). When applying these criteria, good agreement was found between the tested methods. Ambient ionization techniques were effective at detecting SARMs at pharmacologically relevant doses, i.e., approximately above 1 mg per capsule, although they may fail to detect lower levels or isomeric species. It is demonstrated that when adhering to a set of clear and consistent rules, ambient mass spectrometry can be employed as a qualitative technique for the screening of illegal SARMs with sufficient confidence and without the necessity to perform a regular LC-MS analysis.
650    12
$a androgenní receptory $x metabolismus $7 D011944
650    _2
$a doping ve sportu $x prevence a kontrola $7 D004300
650    _2
$a hmotnostní spektrometrie $x metody $7 D013058
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
650    _2
$a potravní doplňky $x analýza $7 D019587
650    _2
$a odhalování abúzu drog $x metody $7 D015813
650    _2
$a antagonisté androgenních receptorů $x analýza $7 D059002
650    _2
$a lidé $7 D006801
650    _2
$a chromatografie kapalinová $x metody $7 D002853
655    _2
$a časopisecké články $7 D016428
700    1_
$a Konvalinková, Jitka $u Department of Analytical Chemistry, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic
700    1_
$a Vágnerová, Magdaléna $u Department of Analytical Chemistry, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic; Forensic Laboratory of Biologically Active Substances, Department of Chemistry of Natural Compounds, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic
700    1_
$a Kuchař, Martin $u Forensic Laboratory of Biologically Active Substances, Department of Chemistry of Natural Compounds, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic
700    1_
$a Buček, Jan $u Plasmion GmbH, Am Mittleren Moos 48, 86167, Augsburg, Germany
700    1_
$a Vrkoslav, Vladimír $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 166 00, Prague 6, Czech Republic
700    1_
$a Sýkora, David $u Department of Analytical Chemistry, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic
700    1_
$a Cvačka, Josef $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 166 00, Prague 6, Czech Republic
700    1_
$a Volny, Michael $u Department of Analytical Chemistry, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic; Institute of Microbiology of the Czech Academy of Sciences, Vídeňská 1083, 142 00, Prague 4, Czech Republic. Electronic address: volnyi@vscht.cz
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 277 (20240606), s. 126358
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38879944 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20241015 $b ABA008
991    __
$a 20241024111705 $b ABA008
999    __
$a ok $b bmc $g 2201775 $s 1231121
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 277 $c - $d 126358 $e 20240606 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20241015

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...