Je něco špatně v tomto záznamu ?
Particle tracking, recognition and LET evaluation of out-of-field proton therapy delivered to a phantom with implants
C. Bălan, C. Granja, G. Mytsin, S. Shvidky, A. Molokanov, L. Marek, V. Chiș, C. Oancea
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
PubMed
38986478
DOI
10.1088/1361-6560/ad61b8
Knihovny.cz E-zdroje
- MeSH
- fantomy radiodiagnostické * MeSH
- lidé MeSH
- lineární přenos energie * MeSH
- neuronové sítě MeSH
- plánování radioterapie pomocí počítače metody MeSH
- protézy a implantáty MeSH
- protonová terapie * metody přístrojové vybavení MeSH
- radiační rozptyl MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Objective.This study aims to assess the composition of scattered particles generated in proton therapy for tumors situated proximal to some titanium (Ti) dental implants. The investigation involves decomposing the mixed field and recording Linear Energy Transfer (LET) spectra to quantify the influence of metallic dental inserts located behind the tumor.Approach.A therapeutic conformal proton beam was used to deliver the treatment plan to an anthropomorphic head phantom with two types of implants inserted in the target volume (made of Ti and plastic, respectively). The scattered radiation resulted during the irradiation was detected by a hybrid semiconductor pixel detector MiniPIX Timepix3 that was placed distal to the Spread-out Bragg peak. Visualization and field decomposition of stray radiation were generated using algorithms trained in particle recognition based on artificial intelligence neural networks (AI NN). Spectral sensitive aspects of the scattered radiation were collected using two angular positions of the detector relative to the beam direction: 0° and 60°.Results.Using AI NN, 3 classes of particles were identified: protons, electrons & photons, and ions & fast neutrons. Placing a Ti implant in the beam's path resulted in predominantly electrons and photons, contributing 52.2% of the total number of detected particles, whereas for plastic implants, the contribution was 65.4%. Scattered protons comprised 45.5% and 31.9% with and without metal inserts, respectively. The LET spectra were derived for each group of particles identified, with values ranging from 0.01 to 7.5 keVμm-1for Ti implants/plastic implants. The low-LET component was primarily composed of electrons and photons, while the high-LET component corresponded to protons and ions.Significance.This method, complemented by directional maps, holds the potential for evaluating and validating treatment plans involving stray radiation near organs at risk, offering precise discrimination of the mixed field, and enhancing in this way the LET calculation.
Department of Radiotherapy The Oncology Institute 'Prof Dr Ion Chiricuta' Cluj Napoca Romania
Faculty of Physics Babeș Bolyai University Cluj Napoca Romania
International Intergovernmental Organization Joint Institute for Nuclear Research Dubna Russia
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24019660
- 003
- CZ-PrNML
- 005
- 20241024110715.0
- 007
- ta
- 008
- 241015s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1088/1361-6560/ad61b8 $2 doi
- 035 __
- $a (PubMed)38986478
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Bălan, Cristina $u Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Romania $u Department of Radiotherapy, The Oncology Institute 'Prof. Dr Ion Chiricuta', Cluj-Napoca, Romania $1 https://orcid.org/000000019971983X
- 245 10
- $a Particle tracking, recognition and LET evaluation of out-of-field proton therapy delivered to a phantom with implants / $c C. Bălan, C. Granja, G. Mytsin, S. Shvidky, A. Molokanov, L. Marek, V. Chiș, C. Oancea
- 520 9_
- $a Objective.This study aims to assess the composition of scattered particles generated in proton therapy for tumors situated proximal to some titanium (Ti) dental implants. The investigation involves decomposing the mixed field and recording Linear Energy Transfer (LET) spectra to quantify the influence of metallic dental inserts located behind the tumor.Approach.A therapeutic conformal proton beam was used to deliver the treatment plan to an anthropomorphic head phantom with two types of implants inserted in the target volume (made of Ti and plastic, respectively). The scattered radiation resulted during the irradiation was detected by a hybrid semiconductor pixel detector MiniPIX Timepix3 that was placed distal to the Spread-out Bragg peak. Visualization and field decomposition of stray radiation were generated using algorithms trained in particle recognition based on artificial intelligence neural networks (AI NN). Spectral sensitive aspects of the scattered radiation were collected using two angular positions of the detector relative to the beam direction: 0° and 60°.Results.Using AI NN, 3 classes of particles were identified: protons, electrons & photons, and ions & fast neutrons. Placing a Ti implant in the beam's path resulted in predominantly electrons and photons, contributing 52.2% of the total number of detected particles, whereas for plastic implants, the contribution was 65.4%. Scattered protons comprised 45.5% and 31.9% with and without metal inserts, respectively. The LET spectra were derived for each group of particles identified, with values ranging from 0.01 to 7.5 keVμm-1for Ti implants/plastic implants. The low-LET component was primarily composed of electrons and photons, while the high-LET component corresponded to protons and ions.Significance.This method, complemented by directional maps, holds the potential for evaluating and validating treatment plans involving stray radiation near organs at risk, offering precise discrimination of the mixed field, and enhancing in this way the LET calculation.
- 650 12
- $a protonová terapie $x metody $x přístrojové vybavení $7 D061766
- 650 12
- $a fantomy radiodiagnostické $7 D019047
- 650 12
- $a lineární přenos energie $7 D018499
- 650 _2
- $a protézy a implantáty $7 D019736
- 650 _2
- $a radiační rozptyl $7 D012542
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a neuronové sítě $7 D016571
- 650 _2
- $a plánování radioterapie pomocí počítače $x metody $7 D011880
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Granja, Carlos $u ADVACAM, Prague, Czech Republic $1 https://orcid.org/0000000243981553
- 700 1_
- $a Mytsin, Gennady $u International Intergovernmental Organization Joint Institute for Nuclear Research (JINR), Dubna, Russia
- 700 1_
- $a Shvidky, Sergey $u International Intergovernmental Organization Joint Institute for Nuclear Research (JINR), Dubna, Russia
- 700 1_
- $a Molokanov, Alexander $u International Intergovernmental Organization Joint Institute for Nuclear Research (JINR), Dubna, Russia
- 700 1_
- $a Marek, Lukas $u ADVACAM, Prague, Czech Republic
- 700 1_
- $a Chiș, Vasile $u Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Romania
- 700 1_
- $a Oancea, Cristina $u ADVACAM, Prague, Czech Republic $1 https://orcid.org/0000000217459702
- 773 0_
- $w MED00003821 $t Physics in medicine and biology $x 1361-6560 $g Roč. 69, č. 16 (2024)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38986478 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20241015 $b ABA008
- 991 __
- $a 20241024110709 $b ABA008
- 999 __
- $a ok $b bmc $g 2202100 $s 1231633
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 69 $c 16 $e 20240730 $i 1361-6560 $m Physics in medicine and biology $n Phys Med Biol $x MED00003821
- LZP __
- $a Pubmed-20241015