Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Vascular Damage and Repair - Are Small-Diameter Vascular Grafts Still the "Holy Grail" of Tissue Engineering

L. Bačáková, J. Chlupáč, E. Filová, J. Musílková, J. Tomšů, YC. Wu, L. Svobodová, Š. Pražák, A. Brož

. 2024 ; 73 (Suppl. 1) : S335-S363. [pub] 20240531

Status minimální Jazyk angličtina Země Česko

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc25005566

Cardiovascular diseases are the most important cause of morbidity and mortality in the civilized world. Stenosis or occlusion of blood vessels leads not only to events that are directly life-threatening, such as myocardial infarction or stroke, but also to a significant reduction in quality of life, for example in lower limb ischemia as a consequence of metabolic diseases. The first synthetic polymeric vascular replacements were used clinically in the early 1950s. However, they proved to be suitable only for larger-diameter vessels, where the blood flow prevents the attachment of platelets, pro-inflammatory cells and smooth muscle cells on their inner surface, whereas in smaller-diameter grafts (6 mm or less), these phenomena lead to stenosis and failure of the graft. Moreover, these polymeric vascular replacements, like biological grafts (decellularized or devitalized), are cell-free, i.e. there are no reconstructed physiological layers of the blood vessel wall, i.e. an inner layer of endothelial cells to prevent thrombosis, a middle layer of smooth muscle cells to perform the contractile function, and an outer layer to provide innervation and vascularization of the vessel wall. Vascular substitutes with these cellular components can be constructed by tissue engineering methods. However, it has to be admitted that even about 70 years after the first polymeric vascular prostheses were implanted into human patients, there are still no functional small-diameter vascular grafts on the market. The damage to small-diameter blood vessels has to be addressed by endovascular approaches or by autologous vascular substitutes, which leads to some skepticism about the potential of tissue engineering. However, new possibilities of this approach lie in the use of modern technologies such as 3D bioprinting and/or electrospinning in combination with stem cells and pre-vascularization of tissue-engineered vascular grafts. In this endeavor, sex-related differences in the removal of degradable biomaterials by the cells and in the behavior of stem cells and pre-differentiated vascular cells need to be taken into account. Key words: Blood vessel prosthesis, Regenerative medicine, Stem cells, Footprint-free iPSCs, sr-RNA, Dynamic bioreactor, Sex-related differences.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25005566
003      
CZ-PrNML
005      
20250312151229.0
007      
ta
008      
250213s2024 xr f 000 0|eng||
009      
AR
024    7_
$a 10.33549/physiolres.935294 $2 doi
035    __
$a (PubMed)38836460
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Bačáková, L $u Laboratory of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Prague, Czech Republic. Lucie.Bacakova@fgu.cas.cz
245    10
$a Vascular Damage and Repair - Are Small-Diameter Vascular Grafts Still the "Holy Grail" of Tissue Engineering / $c L. Bačáková, J. Chlupáč, E. Filová, J. Musílková, J. Tomšů, YC. Wu, L. Svobodová, Š. Pražák, A. Brož
520    9_
$a Cardiovascular diseases are the most important cause of morbidity and mortality in the civilized world. Stenosis or occlusion of blood vessels leads not only to events that are directly life-threatening, such as myocardial infarction or stroke, but also to a significant reduction in quality of life, for example in lower limb ischemia as a consequence of metabolic diseases. The first synthetic polymeric vascular replacements were used clinically in the early 1950s. However, they proved to be suitable only for larger-diameter vessels, where the blood flow prevents the attachment of platelets, pro-inflammatory cells and smooth muscle cells on their inner surface, whereas in smaller-diameter grafts (6 mm or less), these phenomena lead to stenosis and failure of the graft. Moreover, these polymeric vascular replacements, like biological grafts (decellularized or devitalized), are cell-free, i.e. there are no reconstructed physiological layers of the blood vessel wall, i.e. an inner layer of endothelial cells to prevent thrombosis, a middle layer of smooth muscle cells to perform the contractile function, and an outer layer to provide innervation and vascularization of the vessel wall. Vascular substitutes with these cellular components can be constructed by tissue engineering methods. However, it has to be admitted that even about 70 years after the first polymeric vascular prostheses were implanted into human patients, there are still no functional small-diameter vascular grafts on the market. The damage to small-diameter blood vessels has to be addressed by endovascular approaches or by autologous vascular substitutes, which leads to some skepticism about the potential of tissue engineering. However, new possibilities of this approach lie in the use of modern technologies such as 3D bioprinting and/or electrospinning in combination with stem cells and pre-vascularization of tissue-engineered vascular grafts. In this endeavor, sex-related differences in the removal of degradable biomaterials by the cells and in the behavior of stem cells and pre-differentiated vascular cells need to be taken into account. Key words: Blood vessel prosthesis, Regenerative medicine, Stem cells, Footprint-free iPSCs, sr-RNA, Dynamic bioreactor, Sex-related differences.
650    _2
$a lidé $7 D006801
650    12
$a tkáňové inženýrství $x metody $7 D023822
650    12
$a cévní protézy $7 D001807
650    _2
$a zvířata $7 D000818
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Chlupáč, J
700    1_
$a Filová, E
700    1_
$a Musílková, J
700    1_
$a Tomšů, J
700    1_
$a Wu, Yu-Chieh
700    1_
$a Svobodová, L
700    1_
$a Pražák, Š
700    1_
$a Brož, A
773    0_
$w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 73, Suppl. 1 (2024), s. S335-S363
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38836460 $y Pubmed
910    __
$a ABA008 $b A 4120 $c 266 $y - $z 0
990    __
$a 20250213 $b ABA008
991    __
$a 20250312151236 $b ABA008
999    __
$a min $b bmc $g 2283599 $s 1242586
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 73 $c Suppl. 1 $d S335-S363 $e 20240531 $i 1802-9973 $m Physiological research $n Physiol Res $x MED00003824
LZP    __
$a Pubmed-20250213

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...