• Something wrong with this record ?

Sacroiliac joint auricular surface morphology modulates its mechanical environment

P. Henyš, N. Hammer

. 2025 ; 246 (2) : 258-271. [pub] 20241118

Language English Country England, Great Britain

Document type Journal Article

Grant support
24-10862S Czech Science Foundation

The sacroiliac joint (SIJ) exhibits significant variation in auricular surface morphology. This variation influences the mechanics of the SIJ, a central node for transmitting mechanical energy from upper body to lower limbs and vice versa. The impact of the auricular surface morphology on stress and deformation in the SIJ remains poorly understood to date. Computed tomography scans obtained from 281 individuals were included to extract the geometry of the pelvic ring. Then, the auricular surface area, SIJ cartilage thickness, and total SIJ cartilage volume were identified. Based on these reconstructions, 281 finite element models were created to simulate SIJ mechanical loading. It was found that SIJ cartilage thickness only weakly depended on age or laterality, while being strongly sex sensitive. Auricular surface area and SIJ cartilage volume depended weakly and non-linearly on age, peaking around menopause in females, but without significant laterality effect. Larger SIJs, characterized by greater auricular area and cartilage volume, exhibited reduced stress and deformation under loading. These findings highlight the significant role of SIJ morphology in its biomechanical response, suggesting a potential link between morphological variations and the risk of SIJ dysfunction. Understanding this relationship could improve diagnosis and targeted treatment strategies for SIJ-related conditions.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25010098
003      
CZ-PrNML
005      
20250429134647.0
007      
ta
008      
250415s2025 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1111/joa.14160 $2 doi
035    __
$a (PubMed)39556079
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Henyš, Petr $u Institute of New Technologies and Applied Informatics, Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czechia
245    10
$a Sacroiliac joint auricular surface morphology modulates its mechanical environment / $c P. Henyš, N. Hammer
520    9_
$a The sacroiliac joint (SIJ) exhibits significant variation in auricular surface morphology. This variation influences the mechanics of the SIJ, a central node for transmitting mechanical energy from upper body to lower limbs and vice versa. The impact of the auricular surface morphology on stress and deformation in the SIJ remains poorly understood to date. Computed tomography scans obtained from 281 individuals were included to extract the geometry of the pelvic ring. Then, the auricular surface area, SIJ cartilage thickness, and total SIJ cartilage volume were identified. Based on these reconstructions, 281 finite element models were created to simulate SIJ mechanical loading. It was found that SIJ cartilage thickness only weakly depended on age or laterality, while being strongly sex sensitive. Auricular surface area and SIJ cartilage volume depended weakly and non-linearly on age, peaking around menopause in females, but without significant laterality effect. Larger SIJs, characterized by greater auricular area and cartilage volume, exhibited reduced stress and deformation under loading. These findings highlight the significant role of SIJ morphology in its biomechanical response, suggesting a potential link between morphological variations and the risk of SIJ dysfunction. Understanding this relationship could improve diagnosis and targeted treatment strategies for SIJ-related conditions.
650    _2
$a lidé $7 D006801
650    _2
$a ženské pohlaví $7 D005260
650    12
$a sakroiliakální kloub $x anatomie a histologie $x fyziologie $x diagnostické zobrazování $7 D012446
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a dospělí $7 D000328
650    _2
$a lidé středního věku $7 D008875
650    _2
$a biomechanika $x fyziologie $7 D001696
650    12
$a počítačová rentgenová tomografie $7 D014057
650    _2
$a mladý dospělý $7 D055815
650    _2
$a senioři $7 D000368
650    _2
$a analýza metodou konečných prvků $7 D020342
650    _2
$a mladiství $7 D000293
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a mechanický stres $7 D013314
655    _2
$a časopisecké články $7 D016428
700    1_
$a Hammer, Niels $u Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University Graz, Graz, Austria $u Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany $u Division of Biomechatronics, Fraunhofer Institute for Machine Tools and Forming Technology IWU, Dresden, Germany $1 https://orcid.org/0000000182309383
773    0_
$w MED00002511 $t Journal of anatomy $x 1469-7580 $g Roč. 246, č. 2 (2025), s. 258-271
856    41
$u https://pubmed.ncbi.nlm.nih.gov/39556079 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250415 $b ABA008
991    __
$a 20250429134643 $b ABA008
999    __
$a ok $b bmc $g 2311456 $s 1247179
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2025 $b 246 $c 2 $d 258-271 $e 20241118 $i 1469-7580 $m Journal of anatomy $n J Anat $x MED00002511
GRA    __
$a 24-10862S $p Czech Science Foundation
LZP    __
$a Pubmed-20250415

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...