Cross-spectral analysis of heart rate and blood pressure modulations
Language English Country United States Media print
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Diabetes Mellitus, Type 2 physiopathology MeSH
- Adult MeSH
- Electrocardiography methods statistics & numerical data MeSH
- Hypertension physiopathology MeSH
- Myocardial Infarction physiopathology MeSH
- Coronary Disease physiopathology MeSH
- Blood Pressure * MeSH
- Middle Aged MeSH
- Humans MeSH
- Blood Pressure Determination methods statistics & numerical data MeSH
- Posture physiology MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Heart Rate * MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The cross-spectral analysis of heart rate (HR) and blood pressure (BP) variabilities provides "amplitude" and "phase" related measures. Compared to the amplitude measure, that is the baroreflex gain, the phase related measure characterizing the time lag between HR and BP oscillations has been studied to a much lesser extent. A population of 103 patients (73 men, 30 women, aged 53 +/- 12, range 20-82 years) referred for the management of coronary artery disease and/or hypertension were studied. In each subject, electrocardiogram and BP recordings were obtained in the supine and sitting positions of 5 minutes of rest (spontaneous respiration), 3 minutes of controlled respiration at 0.1 Hz (slow-controlled respiration), and 3 minutes of controlled respiration at 0.33 Hz (fast-controlled respiration). The frequency of maximum coherence (above the arbitrary threshold of 0.5) of BP and RR interval variabilities was searched between 0.033-0.133 Hz and 0.200-0.400 Hz to obtain baroreflex gain and phase shift in low and high frequency bands, respectively. Mean phase shifts of -79.1 and -67.0 degrees (-2.4 and -2.1 s) were found during slow-controlled respiration in the supine and sitting body positions, respectively. The mean phase shift between systolic BP and RR interval in the low frequency band was found between 83 and -109 degrees for body positions and respiration regimes. The actual baroreflex related time lag between systolic BP and RR variations was found between 3.5 and 5.1 seconds. The study concludes that the appropriate, and not always easy, selection of the frequency of maximum coherence between BP and HR oscillation is crucial for an accurate cross-spectral assessment of baroreflex sensitivity.
References provided by Crossref.org