Ultrasound estimation of volume of pleural fluid in mechanically ventilated patients

. 2006 Feb ; 32 (2) : 318. [epub] 20060124

Jazyk angličtina Země Spojené státy americké Médium print-electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid16432674
Odkazy

PubMed 16432674
DOI 10.1007/s00134-005-0024-2
PII: 10.1007/s00134-005-0024-2
Knihovny.cz E-zdroje

OBJECTIVE: The aim was to develop a practical method for estimation of the volume of pleural effusion using ultrasonography in mechanically ventilated patients. DESIGN: Prospective observational study. SETTING: 20-bed general intensive care unit in the university hospital. PATIENTS AND PARTICIPANTS: 81 patients were included after initial suspicion of pleural fluid on chest supine X-ray and pre-puncture ultrasound confirming effusion. Patients with thoracic deformities, post-lung surgery, with diaphragm pathology, haemothorax, empyema and with incomplete aspiration of pleural fluid on post-puncture ultrasound were excluded. INTERVENTIONS: Patients were supine with mild trunk elevation at 15 degrees . Probe was moved upwards in posterior axillary line, and transverse section perpendicular to the body axis was obtained with pleural separation visible at lung base. The maximal distance between parietal and visceral pleura (Sep) in end-expiration was recorded. Thoracentesis was performed at previous probe position and volume of pleural fluid (V) recorded. MEASUREMENTS AND RESULTS: 92 effusions were evaluated and drained; 11 (12%) were excluded for incomplete aspiration. Success rate of obtaining fluid under ultrasound guidance was 100%; the incidence of pneumothorax or bleeding was zero. Mean Sep was 35+/-13 mm. Mean V was 658+/-320 ml. Significant positive correlation between both Sep and V was found: r=0.72; r(2)=0.52; p<0.001. The amount of pleural fluid volume can be estimated with the simplified formula: V (ml)=20 x Sep (mm). Mean prediction error of V using Sep was 158.4+/-160.6 ml. CONCLUSIONS: Easy quantification of pleural fluid may help to decide about performing thoracentesis in high-risk patients, although thoracentesis under ultrasound guidance appears to be a safe procedure.

Zobrazit více v PubMed

Chest. 1994 Oct;106(4):1209-14 PubMed

Chest. 1995 Nov;108(5):1345-8 PubMed

Intensive Care Med. 2004 Feb;30(2):276-81 PubMed

Chest. 2004 Mar;125(3):1059-62 PubMed

Radiology. 1994 Jun;191(3):681-4 PubMed

Intensive Care Med. 1999 Sep;25(9):955-8 PubMed

Chest. 2002 Jan;121(1):178-84 PubMed

Crit Care Med. 2003 Apr;31(4 Suppl):S300-4 PubMed

Crit Care Med. 2005 Aug;33(8):1757-63 PubMed

Acta Radiol. 1995 Nov;36(6):626-32 PubMed

Chest. 2005 Jan;127(1):224-32 PubMed

Surgery. 1998 Feb;123(2):137-43 PubMed

Chest. 2003 Feb;123(2):418-23 PubMed

J Trauma. 2004 Dec;57(6):1184-8 PubMed

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...