Vyuzití torické nitroocní cocky pri re- sení komplikované katarakty a vyso- kého stupne astigmatismu
[The use of the toric intraocular lens in treatment of complicated cataract and high degree astigmatism]
Jazyk čeština Země Česko Médium print
Typ dokumentu anglický abstrakt, časopisecké články
PubMed
17419319
- MeSH
- astigmatismus komplikace chirurgie MeSH
- dospělí MeSH
- extrakce katarakty * MeSH
- implantace nitrooční čočky * MeSH
- katarakta komplikace MeSH
- lidé středního věku MeSH
- lidé MeSH
- nitrooční čočky * MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
The authors refer about highly effective and in our ophthalmology not yet described method of surgical treatment of complicated cataract in patients with high degree of preexisting astigmatism over 3.0 cylindrical diopters. According to the etiology of astigmatism, in the group, there are patients with cataract and high ametropia after previous corneal transplantation and patients with cataract and preexisting high ametropia without any previous surgery. The referred group consists of 14 patients (19 eyes), and 9 of them (9 eyes) underwent in the past penetrating keratoplasty (PK) due to keratoconus at our department. The common sign of this subgroup was unsatisfactory postoperative refraction and later on the progressive cataract development. The other part of the group consisted of 5 patients (5 eyes) and they underwent no surgery in the past. For the surgical treatment of cataract and astigmatism at once we have used the individually manufactured silicone toric intraocular lens made by the company Human Optics (type MS 6116 TU). The average age of the whole group at the time of the cataract surgery was 51.5 +/- 6.8 years (range, 39-66 years). The group consisted of 8 women (57.1%) and 6 men (42.9%). The average duration of the period between the keratoplasty and the cataract surgery was 4.8 +/- 3.6 years. The uncorrected visual acuity before the cataract surgery was 0.10 +/- 0.11, and the best-corrected visual acuity was 0.39 +/- 0.22. The average value of the preoperative refractive error was +3.4 +/- 5.0 dioptres (range, -11.0 to +10.0 dioptres) and -6.4 +/- 2.3 cylindrical dioptres (range, -12.0 to -3.0 cylindical dioptres). The average follow up period was 9.6 months (range, 4-18 months). In the postoperative period we noticed improving of the uncorrected visual acuity to the value 0.50 +/- 0.26, and the best-corrected visual acuity improved finally to 0.56 +/- 0.26. The final average refractive error decreased to 0.44 +/- 0.86 dioptres and -1.8 +/- 0.77 cylindrical dioptres.