Three-dimensional electrogram in spherical coordinates: application to ischemia analysis

. 2010 ; 59 Suppl 1 () : S51-S58.

Jazyk angličtina Země Česko Médium print

Typ dokumentu časopisecké články, práce podpořená grantem, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/pmid20626220

Three-dimensional electrogram was used for analysis of ischemia manifestation in isolated hearts. Three parameters based on spherical coordination system were used in this study - amplitude of electrical heart vector, its azimuth and elevation. The parameters were presented as a trend. This approach reflected ischemic changes in a manner which can be easily observed and evaluated. Ischemia was analysed in seven isolated hearts of New Zealand white rabbits. It was found that (a) ischemia changes heart electric vector, (b) ischemic preconditioning has a protective effect, and (c) both of these findings can be clearly observed by the proposed method.

Citace poskytuje Crossref.org

Najít záznam

Citační ukazatele