First inter-laboratory comparison exercise for the determination of anticancer drugs in aqueous samples

. 2016 Aug ; 23 (15) : 14692-704. [epub] 20150715

Jazyk angličtina Země Německo Médium print-electronic

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid26169820
Odkazy

PubMed 26169820
DOI 10.1007/s11356-015-4982-9
PII: 10.1007/s11356-015-4982-9
Knihovny.cz E-zdroje

The results of an inter-laboratory comparison exercise to determine cytostatic anticancer drug residues in surface water, hospital wastewater and wastewater treatment plant effluent are reported. To obtain a critical number of participants, an invitation was sent out to potential laboratories identified to have the necessary knowledge and instrumentation. Nine laboratories worldwide confirmed their participation in the exercise. The compounds selected (based on the extent of use and laboratories capabilities) included cyclophosphamide, ifosfamide, 5-fluorouracil, gemcitabine, etoposide, methotrexate and cisplatinum. Samples of spiked waste (hospital and wastewater treatment plant effluent) and surface water, and additional non-spiked hospital wastewater, were prepared by the organising laboratory (Jožef Stefan Institute) and sent out to each participant partner for analysis. All analytical methods included solid phase extraction (SPE) and the use of surrogate/internal standards for quantification. Chemical analysis was performed using either liquid or gas chromatography mass (MS) or tandem mass (MS/MS) spectrometry. Cisplatinum was determined using inductively coupled plasma mass spectrometry (ICP-MS). A required minimum contribution of five laboratories meant that only cyclophosphamide, ifosfamide, methotrexate and etoposide could be included in the statistical evaluation. z-score and Q test revealed 3 and 4 outliers using classical and robust approach, respectively. The smallest absolute differences between the spiked values and the measured values were observed in the surface water matrix. The highest within-laboratory repeatability was observed for methotrexate in all three matrices (CV ≤ 12 %). Overall, inter-laboratory reproducibility was poor for all compounds and matrices (CV 27-143 %) with the only exception being methotrexate measured in the spiked hospital wastewater (CV = 8 %). Random and total errors were identified by means of Youden plots.

Zobrazit více v PubMed

J Chromatogr A. 2013 May 17;1290:62-72 PubMed

Anal Bioanal Chem. 2013 Jul;405(18):5937-52 PubMed

J Pharm Biomed Anal. 2010 Sep 21;53(1):109-12 PubMed

J Chromatogr A. 2013 Mar 8;1280:64-74 PubMed

Sci Total Environ. 2014 Nov 1;497-498:68-77 PubMed

J Chromatogr A. 2007 Jul 27;1158(1-2):158-67 PubMed

Environ Pollut. 2010 Mar;158(3):658-62 PubMed

Talanta. 2010 Jun 15;81(4-5):1189-96 PubMed

Talanta. 2013 Nov 15;116:290-9 PubMed

J Chromatogr A. 2011 Nov 25;1218(47):8519-28 PubMed

J Chromatogr A. 2003 Aug 22;1010(1):63-74 PubMed

Sci Total Environ. 2014 Jun 1;482-483:389-98 PubMed

Chemosphere. 2014 Nov;115:59-66 PubMed

Ann Occup Hyg. 2013 Mar;57(2):240-50 PubMed

Chemosphere. 2015 Jan;119 Suppl:S42-50 PubMed

Environ Pollut. 2014 Oct;193:216-223 PubMed

Bull Environ Contam Toxicol. 2010 Jan;84(1):39-45 PubMed

Ann Occup Hyg. 2005 Oct;49(7):619-28 PubMed

Talanta. 2008 Jul 30;76(3):580-90 PubMed

Sci Total Environ. 2015 Sep 15;527-528:465-73 PubMed

Nejnovějších 20 citací...

Zobrazit více v
Medvik | PubMed

Surface Wipe Sampling of Hazardous Medicinal Products: A European Interlaboratory Comparison Study

. 2025 Oct ; 17 (10) : 1955-1964. [epub] 20250505

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...