Vascular stenosis asymmetry influences considerably pressure gradient and flow volume

. 2016 ; 65 (1) : 63-9. [epub] 20151124

Jazyk angličtina Země Česko Médium print-electronic

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid26596320

Vascular stenosis is often described only by its percentage in both clinical and scientific praxis. Previous studies gave inconclusive results regarding the effect of stenosis eccentricity on its hemodynamic effect. The aim of this experimental study was to investigate and quantify the effect of stenosis severity and eccentricity on the pressure drop. A combination of pressure and flow measurements by Particle Imaging Velocimetry (PIV) method was used. Models of the same stenosis significance but with different levels of eccentricity were studied in vitro by PIV. This study has shown that stenosis asymmetry is associated with more profound pressure drop and flow volume decrease. On the contrary, pressure drop and flow volume decrease were not further significantly influenced by the level of asymmetry. Hemodynamic changes associated with stenosis eccentricity must be taken into account in both clinical and scientific studies.

Citace poskytuje Crossref.org

Nejnovějších 20 citací...

Zobrazit více v
Medvik | PubMed

The role of Doppler ultrasonography in vascular access surveillance-controversies continue