LC-MS/MS method for determination of cyclin-dependent kinase inhibitors, BP-14 and BP-20, and its application in pharmacokinetic study in rat
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu časopisecké články
PubMed
29753211
DOI
10.1016/j.jchromb.2018.04.049
PII: S1570-0232(17)32039-1
Knihovny.cz E-zdroje
- Klíčová slova
- BP-14, BP-20, Cyclin-dependent kinase inhibitor, Pharmacokinetics, Tissue distribution,
- MeSH
- 2-aminopurin analogy a deriváty analýza farmakokinetika MeSH
- biologická dostupnost MeSH
- cykliny chemie MeSH
- hepatobiliární exkrece účinky léků MeSH
- inhibitory proteinkinas aplikace a dávkování analýza chemie farmakokinetika MeSH
- intravenózní podání metody MeSH
- kalibrace MeSH
- krysa rodu Rattus MeSH
- lidé MeSH
- limita detekce MeSH
- molekulární struktura MeSH
- potkani Wistar MeSH
- protinádorové látky aplikace a dávkování analýza chemie farmakokinetika MeSH
- reprodukovatelnost výsledků MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- tkáňová distribuce účinky léků MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- vztahy mezi strukturou a aktivitou MeSH
- zvířata MeSH
- Check Tag
- krysa rodu Rattus MeSH
- lidé MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- 2-aminopurin MeSH
- cykliny MeSH
- inhibitory proteinkinas MeSH
- N2-(4-aminocyclohexyl)-9-cyclopentyl-N6-((6-(2-furyl)-3-pyridyl)methyl)purine-2,6-diamine MeSH Prohlížeč
- protinádorové látky MeSH
N2-(4-Amino-cyclohexyl)-9-cyclopentyl-N6-(6-furan-2-yl-pyridine-3-ylmethyl)-9H-purine-2,6-diamine (BP-14) and 2-(5-{[2-(4-amino-cyclohexylamino)-9-cyclopentyl-9H-purine-6-ylamino]-methyl}-pyridine-2-yl)-phenol (BP-20) are novel cyclin-dependent kinase inhibitors, structurally related to roscovitine, with significant biological activity. A simple, selective and sensitive liquid chromatography - tandem mass spectrometry method for determining them in rat plasma, using roscovitine as an internal standard, was developed and validated. Chromatographic separation was performed in reversed phase mode on Acquity BEH C18 column (100 × 2.1 mm, 1.7 μm) by gradient elution with mobile phases composed of 15 mM ammonium formate pH 4.0 and methanol at flow rate 0.25 mL/min at 40 °C. The analytes were detected based on their characteristic multiple reaction monitoring transitions in positive electrospray ionization mode m/z 473.07 > 157.93 for BP-14, m/z 499.62 > 184.2 for BP-20 and m/z 355.5 > 90.86 for internal standard. In plasma the method provided good linearity within the entire concentration range: 1-10,000 nmol/L (r2 = 0.9989) for BP-14 and 10-25,000 nmol/L (r2 = 0.9994) for BP-20; the limit of detection was 0.6 nmol/L for BP-14 and 6.1 nmol/L for BP-20. Validation was also performed in bile and urine. The results of validation fit within the acceptance limits following European Medicines Agency guidelines. The method was applied in a pharmacokinetic study of BP-14 and BP-20 in vivo in rats following intravenous and intraduodenal administration including plasma pharmacokinetics, tissue distribution and excretion (renal and biliary). Both compounds showed low bioavailability after intraduodenal administration (0.630 and 1.58% for BP-14 and BP-20, respectively). Distribution into all the analyzed tissues (brain, lungs, liver, kidney, spleen, muscle, adipose tissue) was observed 3 h after single dose administration, the highest and lowest concentrations being reached in the adipose tissue and brain, respectively. The biliary excretion of the parent BP-14 and BP-20 compounds accounted for 4.81% and 10.6% of the doses, respectively, and renal excretion for <0.5% in both cases. The obtained results represent pilot knowledge for further development of a new generation of compounds with strong anticancer activities.
Citace poskytuje Crossref.org