Hypoxemic and hyperoxemic likelihood in pulse oximetry ranges: NICU observational study
Language English Country England, Great Britain Media print-electronic
Document type Journal Article, Observational Study
PubMed
29925540
DOI
10.1136/archdischild-2017-314448
PII: archdischild-2017-314448
Knihovny.cz E-resources
- Keywords
- intensive care, monitoring, neonatology,
- MeSH
- Gestational Age MeSH
- Hyperoxia blood diagnosis MeSH
- Hypoxia blood diagnosis MeSH
- Intensive Care, Neonatal methods MeSH
- Intensive Care Units, Neonatal MeSH
- Oxygen blood MeSH
- Humans MeSH
- Infant, Premature, Diseases blood diagnosis MeSH
- Infant, Premature MeSH
- Infant, Newborn MeSH
- Oximetry methods MeSH
- Partial Pressure MeSH
- Retrospective Studies MeSH
- Check Tag
- Humans MeSH
- Infant, Newborn MeSH
- Publication type
- Journal Article MeSH
- Observational Study MeSH
- Names of Substances
- Oxygen MeSH
OBJECTIVE: Describe the likelihood of hypoxemia and hyperoxemia across ranges of oxygen saturation (SpO2), during mechanical ventilation with supplemental oxygenation. DESIGN: Retrospective observational study. SETTING: University affiliated tertiary care neonatal intensive care unit. PATIENTS: Two groups of neonates based on postmenstrual age (PMA): <32 weeks (n=104) and >36 weeks (n=709). MAIN MEASURES: Hypoxemia was defined as a PaO2 <40 mm Hg, hyperoxemia as a PaO2 of >99 mm Hg and normoxemia as a PaO2 of 50-80 mm Hg. Twenty-five per cent was defined as marked likelihood of hypoxemia or hyperoxemia. RESULTS: From these infants, 18 034 SpO2-PaO2 pairs were evaluated of which 10% were preterm. The PMA (median and IQR) of the two groups were: 28 weeks (27-30) and 40 weeks (38-41). With SpO2 levels between 90% and 95%, the likelihoods of hypoxemia and hyperoxemia were low and balanced. With increasing levels of SpO2, the likelihood of hyperoxemia increased. It became marked in the preterm group when SpO2 was 99%-100% (95% CI 29% to 41%) and in the term group with SpO2 levels of 96%-98% (95% CI 29% to 32%). The likelihood of hypoxemia increased as SpO2 decreased. It became marked in both with SpO2 levels of 80%-85% (95% CI 20% to 31%, 24% to 28%, respectively). CONCLUSIONS: The likelihood of a PaO2 <40 mm Hg is marked with SpO2 below 86%. The likelihood of a PaO2 >99 mm Hg is marked in term infants with SpO2 above 95% and above 98% in preterm infants. SpO2 levels between 90% and 95% are appropriate targets for term and preterm infants.
References provided by Crossref.org