The histological microstructure and in vitro mechanical properties of pregnant and postmenopausal ewe perineal body
Jazyk angličtina Země Spojené státy americké Médium print
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
- MeSH
- biomechanika MeSH
- elastin analýza MeSH
- hladké svalstvo anatomie a histologie fyziologie MeSH
- kolagen analýza MeSH
- kosterní svaly anatomie a histologie fyziologie MeSH
- modely u zvířat MeSH
- ovce MeSH
- perineum anatomie a histologie fyziologie MeSH
- postmenopauza MeSH
- těhotenství MeSH
- tukové buňky MeSH
- zvířata MeSH
- Check Tag
- těhotenství MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Názvy látek
- elastin MeSH
- kolagen MeSH
OBJECTIVE: The mechanical properties and microstructure of the perineal body are important for the improvement of numerical models of pelvic organs. We determined the mechanical parameters and volume fractions of the ewe perineal body as an animal model. METHODS: The 39 specimens of 13 pregnant swifter ewes delivering by cesarean section (aged 2 years, weight 61.2 ± 6.2 kg (mean ± standard deviation) and 24 specimens of 8 postmenopausal swifter ewes 150 days after surgical ovariectomy (aged 7 years, 58.6 ± 4.6 kg)) were loaded uniaxially to determine Young's moduli of elasticity in the small (E0) and large (E1) deformation regions, and ultimate stresses and strains. The 63 adjacent tissue samples were processed histologically to assess volume fractions of smooth and skeletal muscle, adipose cells, elastin, and type I collagen using a stereological point testing grid. We compared the structural and mechanical differences along the ewe perineal body, and between pregnant and postmenopausal groups. RESULTS: The pregnant/postmenopausal perineal body was composed of smooth muscle (12/14%; median), skeletal muscle (12/16%), collagen (10/23%), elastin (8/7%), and adipose cells (6/6%). The E0 was 37/11 kPa (median), E1 was 0.97/1.04 MPa, ultimate stress was 0.55/0.59 MPa, and ultimate strain was 0.90/0.87 for pregnant/postmenopausal perineal body. The perineal body showed a structural and mechanical stability across the sites. The pregnant ewes had a higher amount of skeletal muscle, higher E0, and a less amount of collagen when compared with postmenopausal ewes. CONCLUSIONS: The data can be used as input for models simulating vaginal delivery, pelvic floor prolapsed, or dysfunction.
Biomedical Center Faculty of Medicine Charles University Pilsen Czech Republic
Centre for Surgical Technologies KU Leuven Leuven Belgium
Department of Development and Regeneration KU Leuven Leuven Belgium
Department of Gynecology and Obstetrics University Hospital Pilsen Czech Republic
INEGI Faculdade de Engenharia da Universidade do Porto Porto Portugal
Pelvic Floor Unit University Hospitals KU Leuven Leuven Belgium
Citace poskytuje Crossref.org
Feasibility and safety of antepartum tactile imaging