A green miniaturized aqueous biphasic system prepared with cholinium chloride and a phosphate salt to extract and preconcentrate personal care products in wastewater samples
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu časopisecké články
PubMed
33992994
DOI
10.1016/j.chroma.2021.462219
PII: S0021-9673(21)00343-5
Knihovny.cz E-zdroje
- Klíčová slova
- aqueous biphasic system, cholinium chloride, extraction, high-performance liquid chromatography, personal care products, wastewater,
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- chloridy analýza MeSH
- fosfáty analýza MeSH
- kosmetické přípravky analýza MeSH
- miniaturizace * MeSH
- odpadní voda chemie MeSH
- reprodukovatelnost výsledků MeSH
- rozpouštědla chemie MeSH
- voda analýza MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- chemické látky znečišťující vodu MeSH
- chloridy MeSH
- fosfáty MeSH
- kosmetické přípravky MeSH
- odpadní voda MeSH
- rozpouštědla MeSH
- voda MeSH
A miniaturized extraction/preconcentration method based on an aqueous biphasic system (μ-ABS) was developed with reagents commonly used as food additives: cholinium chloride (ChCl) as main extraction phase, K2HPO4 as salting-out agent, and water as the main component (being the sample for analyses). With the aim of obtaining high enrichment factors, miniaturization, and adequate analytical performance, a point in the biphasic region with the lowest amount of ChCl was selected, corresponding to 1.55% (w/w) of ChCl, 59.5% (w/w) of K2HPO4, and 38.95% (w/w) of water. The green μ-ABS (attending to its main elements and performance mode) was used in combination with high-performance liquid chromatography with diode-array detection (HPLC-DAD) for the determination of 9 personal care products in wastewater samples. The μ-ABS-HPLC-DAD method showed high enrichment factors (up to 100), and quantitative extraction efficiencies for those compounds containing OH groups in their structure, which can undergo hydrogen bonding with ChCl. Thus, limits of quantification down to 0.8 µg·L-1 and extraction efficiencies between 66.4 and 108% (concentration levels of 1.3 and 13 µg·L-1) were reached for the group of parabens and the UV-filter benzophenone-3. The method is characterized by the use of non-harmful reagents and the absence of organic solvents in the entire sample preparation procedure, while being simple, low-cost, easily compatible with HPLC, and highly efficient.
Citace poskytuje Crossref.org