Extracorporeal membrane oxygenation seems to induce impairment of primary hemostasis pathology as measured by a Multiplate analyzer: An observational retrospective study

. 2022 May ; 46 (5) : 899-907. [epub] 20211217

Jazyk angličtina Země Spojené státy americké Médium print-electronic

Typ dokumentu časopisecké články, pozorovací studie

Perzistentní odkaz   https://www.medvik.cz/link/pmid34904233

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) support is often associated with bleeding complications caused by secondary or primary hemostasis pathology. However, there are limited data investigating primary hemostasis using Multiplate aggregometry with specific diagnostics tests for vWF (von Willebrand factor) deficiency. AIMS: The aim of this study was to find out whether short-term ECMO produces the pathology of primary hemostasis that is detected by Multiplate aggregometry and to investigate the pathology of vWF. METHODS: In this study, blood samples of 20 patients undergoing lung transplantations with short-term perioperative ECMO support were analyzed. The multimeric structure, the levels of von Willebrand factor antigen (vWF), ristocetin cofactor (RCo), collagen-binding protein (CB), and the results of multiple electrode aggregometry RISTO (ristocetin), ADP (adenosine diphosphate), ASPI (Aspirin®; arachidonic acid), and TRAP (thrombin receptor activating peptide) tests were compared to the samples obtained before and after ECMO support. RESULTS: The Multiplate ADP and RISTO tests showed the presence of significant pathology in primary hemostasis after surgery (p < 0.05), suggesting the presence of acquired platelet dysfunction. Although the RISTO tests suggest the presence of acquired vWF deficiency, laboratory tests for vWF antigen and RCo and CB tests showed an increase in this case. The multimeric structure of vWF did not show clinically significant deterioration. CONCLUSIONS: Multiple aggregometry ADP, ASPI, and TRAP tests seem to be able to detect primary hemostasis pathology (platelets aggregation and adhesion pathology) that is present during short-term perioperative ECMO support in lung transplantation procedures. Interestingly, RISTO tests seem to be more suitable for the diagnosis of platelet dysfunction than the diagnosis of acquired vWF deficiency in this situation.

Zobrazit více v PubMed

Vaquer S, de Haro C, Peruga P, Oliva JC, Artigas A. Systematic review and meta-analysis of complications and mortality of veno-venous extracorporeal membrane oxygenation for refractory acute respiratory distress syndrome. Ann Intensive Care. 2017;7(1):51. https://doi.org/10.1186/s13613-017-0275-4

Ellouze O, Abbad X, Constandache T, Missaoui A, Berthoud V, Daily T, et al. Risk factors of bleeding in patients undergoing venoarterial extracorporeal membrane oxygenation. Ann Thorac Surg. 2021;111(2):623-8. https://doi.org/10.1016/j.athoracsur.2020.02.012

Aubron C, DePuydt J, Belon F, Bailey M, Schmidt M, Sheldrake J, et al. Predictive factors of bleeding events in adults undergoing extracorporeal membrane oxygenation. Ann Intensive Care. 2016;6(1):97. https://doi.org/10.1186/s13613-016-0196-7

Durila M, Vajter J, Garaj M, Smetak T, Hedvicak P, Berousek J, et al. Acquired primary hemostasis pathology detected by platelet function analyzer 200 seen during extracorporeal membrane oxygenation is sufficient to prevent circuit thrombosis: a pilot study. J Heart Lung Transplant. 2020;39(9):980-2. https://doi.org/10.1016/j.healun.2020.05.015

Balle CM, Jeppesen AN, Christensen S, Hvas AM. Platelet function during extracorporeal membrane oxygenation in adult patients: a systematic review. Front Cardiovasc Med. 2018;5:157. https://doi.org/10.3389/fcvm.2018.00157

Chen Z, Mondal NK, Zheng S, Koenig SC, Slaughter MS, Griffith BP, et al. High shear induces platelet dysfunction leading to enhanced thrombotic propensity and diminished hemostatic capacity. Platelets. 2019;30(1):112-9. https://doi.org/10.1080/09537104.2017.1384542

Chen Z, Mondal NK, Ding J, Koenig SC, Slaughter MS, Wu ZJ. Paradoxical effect of nonphysiological shear stress on platelets and von Willebrand factor. Artif Organs. 2016;40(7):659-68. https://doi.org/10.1111/aor.12606

Tauber H, Ott H, Streif W, Weigel G, Loacker L, Fritz J, et al. Extracorporeal membrane oxygenation induces short-term loss of high-molecular-weight von Willebrand factor multimers. Anesth Analg. 2015;120(4):730-6. https://doi.org/10.1213/ANE.0000000000000554

Schlagenhauf A, Kalbhenn J, Geisen U, Beyersdorf F, Zieger B. Acquired von Willebrand Syndrome and platelet function defects during extracorporeal life support (mechanical circulatory support). Hamostaseologie. 2020;40(2):221-5. https://doi.org/10.1055/a-1150-2016

Kalbhenn J, Schmidt R, Nakamura L, Schelling J, Rosenfelder S, Zieger B. Early diagnosis of acquired von Willebrand Syndrome (AVWS) is elementary for clinical practice in patients treated with ECMO therapy. J Atheroscler Thromb. 2015;22(3):265-71. https://doi.org/10.5551/jat.27268

Kalbhenn J, Schlagenhauf A, Rosenfelder S, Schmutz A, Zieger B. Acquired von Willebrand Syndrome and impaired platelet function during venovenous extracorporeal membrane oxygenation: rapid onset and fast recovery. J Heart Lung Transplant. 2018;37(8):985-91. https://doi.org/10.1016/j.healun.2018.03.013

Hellmann C, Schmutz A, Kalbhenn J. Bleeding during veno-venous ECMO cannot reliably be predicted by rotational thrombelastometry (ROTEM™). Perfusion. 2018;33(4):289-96. https://doi.org/10.1177/0267659117746231

Panigada M, Artoni A, Passamonti SM, Maino A, Mietto C, L'acqua C, et al. Hemostasis changes during veno-venous extracorporeal membrane oxygenation for respiratory support in adults. Minerva Anestesiol. 2016;82(2):170-9.

Wand S, Huber-Petersen JF, Schaeper J, Binder C, Moerer O. Platelet function disturbance during veno-venous ECMO in ARDS patients assessed by multiple electrode aggregometry-a prospective, observational cohort study. J Clin Med. 2019;8(7):1056. https://doi.org/10.3390/jcm8071056

Lansink-Hartgring AO, Hoffmann R, van den Bergh W, de Vries A. Changes in red blood cell properties and platelet function during extracorporeal membrane oxygenation. J Clin Med. 2020;9(4):1168. https://doi.org/10.3390/jcm9041168

Paniccia R, Priora R, Liotta AA, Abbate R. Platelet function tests: a comparative review. Vasc Health Risk Manag. 2015;11:133-48. https://doi.org/10.2147/VHRM.S44469

Pluta J, Nicińska B, Trzebicki J. Multiple electrode aggregometry as a method for platelet function assessment according to the European guidelines. Anaesthesiol Intensive Ther. 2018;50(3):230-3. https://doi.org/10.5603/AIT.a2018.0024

Mutlak H, Reyher C, Meybohm P, Papadopoulos N, Hanke A, Zacharowski K, et al. Multiple electrode aggregometry for the assessment of acquired platelet dysfunctions during extracorporeal circulation. Thorac Cardiovasc Surg. 2015;63(1):21-7. https://doi.org/10.1055/s-0034-1383817

Schmidt DE, Bruzelius M, Majeed A, Odeberg J, Holmström M, Ågren A. Whole blood ristocetin-activated platelet impedance aggregometry (Multiplate) for the rapid detection of Von Willebrand disease. Thromb Haemost. 2017;117(8):1528-33. https://doi.org/10.1160/TH17-02-0129

Ågren A, Holmström M, Schmidt DE, Hosokawa K, Blombäck M, Hjemdahl P. Monitoring of coagulation factor therapy in patients with von Willebrand disease type 3 using a microchip flow chamber system. Thromb Haemost. 2017;117(1):75-85. https://doi.org/10.1160/TH16-06-0430

De Jong A, Eikenboom J. Developments in the diagnostic procedures for von Willebrand disease. J Thromb Haemost. 2016;14(3):449-60. https://doi.org/10.1111/jth.13243

Sharma R, Flood VH. Advances in the diagnosis and treatment of Von Willebrand disease. Blood. 2017;130(22):2386-91. https://doi.org/10.1182/blood-2017-05-782029

Ki KK, Passmore MR, Chan CHH, Malfertheiner Maximilian V, Fanning Jonathon P, Bouquet Mahé, et al. Low flow rate alters haemostatic parameters in an ex-vivo extracorporeal membrane oxygenation circuit. Intensive Care Med Exp. 2019;7(1):51. https://doi.org/10.1186/s40635-019-0264-z

Passmore MR, Ki KK, Chan CHH, Lee T, Bouquet M, Wood ES, et al. The effect of hyperoxia on inflammation and platelet responses in an ex vivo extracorporeal membrane oxygenation circuit. Artif Organs. 2020;44(12):1276-85. https://doi.org/10.1111/aor.13771

Tamura T, Horiuchi H, Imai M, Tada T, Shiomi H, Kuroda M, et al. Unexpectedly high prevalence of acquired von Willebrand Syndrome in patients with severe aortic stenosis as evaluated with a novel large multimer index. J Atheroscler Thromb. 2015;22(11):1115-23. https://doi.org/10.5551/jat.30809

Tamura T, Horiuchi H, Obayashi Y, Fuki M, Imanaka M, Kuroda M, et al. Acquired von Willebrand Syndrome in patients treated with veno-arterial extracorporeal membrane oxygenation. Cardiovasc Interv Ther. 2019;34(4):358-63. https://doi.org/10.1007/s12928-019-00568-y.

Hanke AA, Roberg K, Monaca E, Sellmann T, Weber CF, Rahe-Meyer N, et al. Impact of platelet count on results obtained from multiple electrode platelet aggregometry (Multiplate). Eur J Med Res. 2010;15(5):214-9. https://doi.org/10.1186/2047-783x-15-5-214

Bochsen L, Johansson PI, Kristensen AT, Daugaard G, Ostrowski SR. The influence of platelets, plasma and red blood cells on functional haemostatic assays. Blood Coagul Fibrinolysis. 2011;22(3):167-75. https://doi.org/10.1097/MBC.0b013e3283424911

Durila M, Vajter J, Garaj M, Pollert L, Berousek J, Vachtenheim J Jr, et al. Rotational thromboelastometry reduces blood loss and blood product usage after lung transplantation. J Heart Lung Transplant. 2021;40(7):631-41. https://doi.org/10.1016/j.healun.2021.03.020

Lukito P, Wong A, Jing J, Arthur JF, Marasco SF, Murphy DA, et al. Mechanical circulatory support is associated with loss of platelet receptors glycoprotein Ibα and glycoprotein VI. J Thromb Haemost. 2016;14(11):2253-60. https://doi.org/10.1111/jth.13497

Chen Z, Zhang J, Kareem K, Tran D, Conway RG, Arias K, et al. Device-induced platelet dysfunction in mechanically assisted circulation increases the risks of thrombosis and bleeding. Artif Organs. 2019;43(8):745-55. https://doi.org/10.1111/aor.13445

Chen Z, Zhang J, Li T, Tran D, Griffith BP, Wu ZJ. The impact of shear stress on device-induced platelet hemostatic dysfunction relevant to thrombosis and bleeding in mechanically assisted circulation [published correction appears in Artif Organs. 2020;44(8):907-8]. Artif Organs. 2020;44(5):E201-13. https://doi.org/10.1111/aor.13609

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...