Retinal oxygen saturation in monoclonal gammopathies patients: A pilot study
Jazyk angličtina Země Anglie, Velká Británie Médium print-electronic
Typ dokumentu časopisecké články
Grantová podpora
0098892
The Ministry of Health of the Czech Republic-Conceptual Development of Research Organization
PubMed
36004612
DOI
10.1111/aos.15239
Knihovny.cz E-zdroje
- Klíčová slova
- hyperviscosity-related retinopathy, immunoglobulin-free light chains kappa and lambda, monoclonal gammopathy, monoclonal immunoglobulin, oxymap, retinal oximetry, retinal oxygen saturation, total protein,
- MeSH
- kyslík MeSH
- lidé středního věku MeSH
- lidé MeSH
- oxymetrie metody MeSH
- paraproteinemie * diagnóza MeSH
- pilotní projekty MeSH
- retina MeSH
- retinální cévy MeSH
- saturace kyslíkem * MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- kyslík MeSH
PURPOSE: The aim of this pilot study was to assess oxygen saturation in retinal blood vessels in patients with monoclonal gammopathies (MGs). METHODS: Thirty-one patients with MGs (11 women and 20 men, mean age 65.9 ± 8.9 years) were enrolled during 2016-2020. The patients were diagnosed at the Haemato-Oncology Department and subsequently examined at the Ophthalmology Department before initiating systemic therapy. All patients were subjected to automatic retinal oximetry (Oxymap ehf.) and had their fundus photographed (Topcon TRC-50DX retinal camera). We assessed the association between retinal oxygen saturation (SatO2 ) - arterial SatO2 , venous SatO2 and arterio-venous (AV) difference-and MGs parameters: serum monoclonal immunoglobulin (M-protein) level and serum immunoglobulin-free light chains (FLC kappa and lambda), total protein, serum viscosity, haemoglobin, albumin, lactate dehydrogenase, C-reactive protein, creatinine and serum calcium level. Hyperviscosity-related retinopathy was also evaluated. RESULTS: Statistical analysis showed a significant positive correlation (r = 0.462; p = 0.009) between the AV difference and the haemoglobin level. A significant, medium strong negative correlation was found between the AV difference and the serum levels of the monoclonal light lambda chains (r = -0.450; p = 0.011). Contrary to expectations, no statistically significant correlation was found between retinal oxygen saturation and the total protein or viscosity. CONCLUSION: This study found correlation between retinal oxygen saturation and certain parameters in the blood of patients with MGs. Increasing levels of monoclonal immunoglobulin seem to reduce oxygen absorption in retinal arterioles, resulting in a lower AV difference, particularly in patients with a high free light chain level.
Zobrazit více v PubMed
Baskurt, O.K. & Meiselman, H.J. (2003) Blood rheology and hemodynamics. Seminars in Thrombosis and Hemostasis, 29, 435-450.
Beach, J.M., Schwenzer, K.J., Srinivas, S., Kim, D. & Tiedeman, J.S. (1999) Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation. Journal of Applied Physiology, 86, 748-758.
Crawford, J., Cox, E.B. & Cohen, H.J. (1985) Evaluation of hyperviscosity in monoclonal gammopathies. The American Journal of Medicine, 79, 13-22.
Geirsdottir, A., Palsson, O., Hardarson, S.H., Olafsdottir, O.B., Kristjansdottir, J.V. & Stefánsson, E. (2012) Retinal vessel oxygen saturation in healthy individuals. Investigative Ophthalmology & Visual Science, 53, 5433-5442.
Gustine, J.N., Meid, K., Dubeau, T., Hunter, Z.R., Xu, L., Yang, G. et al. (2017) Serum IgM level as predictor of symptomatic hyperviscosity in patients with Waldenström macroglobulinaemia. British Journal of Haematology, 177, 717-725.
Hardarson, S.H., Harris, A., Karlsson, R.A., Halldorsson, G.H., Kagemann, L., Rechtman, E. et al. (2006) Automatic retinal oximetry. Investigative Ophthalmology & Visual Science, 47, 5011-5016.
Hardarson, S.H., Basit, S., Jonsdottir, T.E., Eysteinsson, T., Halldorsson, G.H., Karlsson, R.A. et al. (2009) Oxygen saturation in human retinal vessels is higher in dark than in light. Investigative Ophthalmology & Visual Science, 50, 2308-2311.
Hübnerová, P., Mlčák, P., Šínová, I., Karhanová, M. & Šín, M. (2020) Current use of automatic retinal oximetry - A review. Ceská a slovenská oftalmologie: casopis Ceské oftalmologické spolecnosti a Slovenské oftalmologické spolecnosti, 76, 3-11.
Izhaky, D., Nelson, D.A., Burgansky-Eliash, Z. & Grinvald, A. (2009) Functional imaging using the retinal function imager: direct imaging of blood velocity, achieving fluorescein angiography-like images without any contrast agent, qualitative oximetry, and functional metabolic signals. Japanese Journal of Ophthalmology, 53, 345-351.
Jeppesen, S.K. & Bek, T. (2019) The retinal oxygen saturation measured by dual wavelength oximetry in larger retinal vessels is influenced by the linear velocity of the blood. Current Eye Research, 44, 46-52.
Klefter, O.N., Lauritsen, A.Ø. & Larsen, M. (2014) Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements. Acta Ophthalmologica, 93, 232-241.
Kwaan, H.C. (2010) Role of plasma proteins in whole blood viscosity: a brief clinical review. Clinical Hemorheology and Microcirculation, 44, 167-176.
Kyle, R.A., BGM, D., Rajkumar, S.V., Landgren, O., Blade, J., Merlini, G. et al. (2010) Monoclonal gammopathy of undetermined significance (MGUS) and smoldering (asymptomatic) multiple myeloma: IMWG consensus perspectives risk factors for progression and guidelines for monitoring and management. Leukemia, 24, 1121-1127.
Landgren, O., Kyle, R.A., Pfeiffer, R.M., Katzmann, J.A., Caporaso, N.E., Hayes, R.B. et al. (2009) Monoclonal gammopathy of undetermined significance (MGUS) consistently precedes multiple myeloma: a prospective study. Blood, 113, 5412-5417.
Menke, M.N., Feke, G.T., McMeel, J.W. & Treon, S.P. (2008) Effect of plasmapheresis on hyperviscosity-related retinopathy and retinal hemodynamics in patients with Waldenström's macroglobulinemia. Investigative Ophthalmology & Visual Science, 49, 1157-1160.
Pika, T., Kosatíková, Z., Juráňová, J. & Mlčák, P. (2014) Non-corpuscular hyperviscosity syndrome in clinical practise. Interní Medicína Pro Praxi, 16, 156-158.
Rajkumar, S.V., Dimopoulos, M.A., Palumbo, A., Blade, J., Merlini, G., Mateos, M.V. et al. (2014) International myeloma working group updated criteria for the diagnosis of multiple myeloma. The Lancet Oncology, 15, e538-e548.
Ščudla, V., Minařík, J., Pika, T. & Bačovský, J. (2018) Differential diagnosis of monoclonal gammopathies from the point of clinical practiceII. Monoclonal gammopathy of undetermined significance and other monoclonal gammopathies of the "non-malignant" origin. Interní Medicína Pro Praxi, 20, 44-48.
Siegel, R.L., Miller, K.D., Fuchs, H.E. & Jemal, A. (2021) Cancer statistics, 2021. CA: a Cancer Journal for Clinicians, 71, 7-33.
Šín, M., Šínová, I., Chrapek, O., Prachařová, Z., Karhanová, M., Langová, K. et al. (2014) The effect of pars plan vitrectomy on oxygen saturation in retinal vessels - A pilot study. Acta Ophthalmologica, 92, 328-331.
Stefánsson, E., Olafsdottir, O.B., Eliasdottir, T.S., Vehmeijer, W., Einarsdottir, A.B., Bek, T. et al. (2019) Retinal oximetry: metabolic imaging for diseases of the retina and brain. Progress in Retinal and Eye Research, 70, 1-22.
Tan, C., Gay, E.M.Q. & Ngo, W.K. (2010) Is age a risk factor for diabetic retinopathy? British Journal of Ophthalmology, 94, 1268.
Tefferi, A. & Vardiman, J.W. (2008) Classification and diagnosis of myeloproliferative neoplasms: the 2008 World Health Organization criteria and point-of-care diagnostic algorithms. Leukemia, 22, 14-22.
Traustason, S., Hardarson, S.H., Gottfredsdottir, M.S., Eysteinsson, T., Karlsson, R.A., Stefánsson, E. et al. (2009) Dorzolamide-timolol combination and retinal vessel oxygen saturation in patients with glaucoma or ocular hypertension. The British Journal of Ophthalmology, 93, 1064-1067.
Wang, J.J., Mitchell, P., Leung, H., Rochtchina, E., Wong, T.Y. & Klein, R. (2003) Hypertensive retinal Vessel Wall signs in a general older population. Hypertension, 42, 534-541.
Weiss, B.M., Abadie, J., Verma, P., Howard, R.S. & Kuehl, W.M. (2009) A monoclonal gammopathy precedes multiple myeloma in most patients. Blood, 113, 5418-5422.
Willerslev, A., Hansen, M.M., Klefter, O.N., Bjerrum, O.W., Hasselbalch, H.C., Clemmensen, S.N. et al. (2017) Non-invasive imaging of retinal blood flow in myeloproliferative neoplasms. Acta Ophthalmologica, 95, 146-152.
Yip, W.F., Siantar, R., Perera, S.A., Milastuti, N., Ho, K.K., Tan, B. et al. (2014) Reliability and determinants of retinal vessel oximetry measurements in healthy eyes. Investigative Opthalmology & Visual Science, 55, 7104-7110.
Yoshida, A., Feke, G.T., Mori, F., Nagaoka, T., Fujio, N., Ogasawara, H. et al. (2003) Reproducibility and clinical application of a newly developed stabilized retinal laser doppler instrument. American Journal of Ophthalmology, 135, 356-361.