Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy
Jazyk angličtina Země Velká Británie, Anglie Médium electronic
Typ dokumentu časopisecké články
PubMed
36821866
DOI
10.1088/1361-6560/acbe8d
Knihovny.cz E-zdroje
- Klíčová slova
- DNA damage, Timepix, aperture, collimation, pencil beam scanning, proton therapy,
- MeSH
- celková dávka radioterapie MeSH
- lidé MeSH
- metoda Monte Carlo MeSH
- plánování radioterapie pomocí počítače metody MeSH
- protonová terapie * metody MeSH
- protony MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- protony MeSH
Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets.Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with publishedin silicobiophysical models to elucidate the potential biological effects of collimated and uncollimated fields.Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keVμm-1in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keVμm-1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction.Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.
Department of Particle Therapy University Hospital Essen Essen Germany
German Cancer Consortium Heidelberg Germany
KU Leuven Department of Oncology Laboratory of Experimental Radiotherapy Leuven Belgium
KU Leuven Faculty of Science Leuven Belgium
Radiobiology Unit Belgian Nuclear Research Centre Mol Belgium
TU Dortmund University Department of Physics Dortmund Germany
UCLouvain Institut de Recherche Expérimentale et Clinique MIRO Lab Brussels Belgium
West German Cancer Center University Hospital Essen Essen Germany
Citace poskytuje Crossref.org