External Quality Assurance Schemes (EQUASs) and Inter-laboratory Comparison Investigations (ICIs) for human biomonitoring of polycyclic aromatic hydrocarbon (PAH) biomarkers in urine as part of the quality assurance programme under HBM4EU
Language English Country Germany Media print-electronic
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
37099846
DOI
10.1016/j.ijheh.2023.114169
PII: S1438-4639(23)00060-3
Knihovny.cz E-resources
- Keywords
- 1-Hydroxypyrene, Analytical method, HBM4EU, Human biomonitoring, Quality control, Z-score,
- MeSH
- Biomarkers urine MeSH
- Biological Monitoring MeSH
- Humans MeSH
- Environmental Monitoring methods MeSH
- Polycyclic Aromatic Hydrocarbons * urine MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Geographicals
- Europe MeSH
- Names of Substances
- Biomarkers MeSH
- Polycyclic Aromatic Hydrocarbons * MeSH
Polycyclic aromatic hydrocarbons (PAHs) were included as priority substances for human biomonitoring (HBM) in the European Human Biomonitoring Initiative (HBM4EU), which intended to harmonise and advance HBM across Europe. For this project, a specific Quality Assurance and Quality Control (QA/QC) programme applying Inter-laboratory Comparison Investigations (ICIs) and External Quality Assurance Schemes (EQUASs) was developed to ensure the comparability and accuracy of participating analytical laboratories. This paper presents the results of four ICI/EQUAS rounds for the determination of 13 PAH metabolites in urine, i.e. 1-naphthol, 2-naphthol, 1,2-dihydroxynaphthalene, 2-, 3- and 9-hydroxyfluorene, 1-, 2-, 3-, 4- and 9-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenzo(a)pyrene. However, 4 PAH metabolites could not be evaluated as the analytical capacity of participating laboratories was too low. Across all rounds and biomarkers, 86% of the participants achieved satisfactory results, although low limits of quantification were required to quantify the urinary metabolites at exposure levels of the general population. Using high-performance liquid or gas chromatography coupled with mass spectrometry (HPLC-MS; GC-MS) and isotope dilution for calibration as well as performing an enzymatic deconjugation step proved to be favourable for the accurate determination of PAHs in urine. Finally, the HBM4EU QA/QC programme identified an international network of laboratories providing comparable results in the analysis of urinary PAH biomarkers, although covering all parameters initially selected was still too challenging.
Aarhus University Department of Environmental Science Frederiksborgvej 399 4000 Roskilde Denmark
ABF Analytisch Biologisches Forschungslabor GmbH Semmelweisstr 5 82152 Planegg Germany
References provided by Crossref.org