Diagnostic Accuracy of Liquid Biomarkers for Clinically Significant Prostate Cancer Detection: A Systematic Review and Diagnostic Meta-analysis of Multiple Thresholds
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu časopisecké články, systematický přehled, metaanalýza
PubMed
37981495
DOI
10.1016/j.euo.2023.10.029
PII: S2588-9311(23)00248-1
Knihovny.cz E-zdroje
- Klíčová slova
- Biomarker, Clinically significant prostate cancer, Diagnosis, Prostate biopsy, Prostate cancer,
- MeSH
- lidé MeSH
- nádorové biomarkery * krev MeSH
- nádory prostaty * diagnóza krev MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- systematický přehled MeSH
- Názvy látek
- nádorové biomarkery * MeSH
CONTEXT: Many liquid biomarkers have entered clinical practice with the praise to improve the detection of clinically significant prostate cancer (csPCa), helping avoid unnecessary prostate biopsies. OBJECTIVE: We aimed to assess the diagnostic accuracy of multianalyte biomarkers for csPCa detection using multiple thresholds. EVIDENCE ACQUISITION: A comprehensive literature search was done through PubMed, Web of Science, and Scopus in March 2023 for prospective and retrospective studies reporting the diagnostic performance of liquid biomarkers for detecting csPCa. The outcomes of interest were the diagnostic performance of liquid biomarkers for csPCa detection and identification of optimal thresholds for each biomarker. EVIDENCE SYNTHESIS: Overall, 49 studies were eligible for this meta-analysis. Using each representative threshold based on the Youden Index, the pooled sensitivity and specificity for detecting csPCa were 0.85 and 0.37 for prostate cancer gene 3 (PCA3), 0.85 and 0.52 for prostate health index (PHI), 0.87 and 0.58 for four kallikrein (4K), 0.82 and 0.56 for SelectMDx, 0.85 and 0.54 for ExoDx, and 0.82 and 0.59 for mi prostate score (MPS), respectively. The diagnostic odds ratio was highest for 4K (8.84), followed by MPS (7.0) and PHI (6.28). According to the meta-analysis incorporating multiple thresholds, the corresponding sensitivity was 0.77 for 4K, 0.69 for PHI, and 0.63 for PCA3; specificity was 0.72 for PHI, 0.70 for 4K, and 0.69 for PCA3. CONCLUSIONS: Regarding the detection of csPCa, 4K had the highest diagnostic performance among the commercial liquid biomarkers. Based on the optimal thresholds calculated by the present meta-analysis, 4K had the highest sensitivity and PHI had the highest specificity for detecting csPCa. Nevertheless, clinical decision-making requires combination strategies between liquid and imaging biomarkers. PATIENT SUMMARY: Novel biomarkers for prostate cancer detection were useful for more accurate diagnosis of clinically significant prostate cancer to avoid unnecessary biopsies.
Cancer Prognostics and Health Outcomes Unit University of Montreal Health Centre Montreal Canada
S H Ho Urology Centre Department of Surgery The Chinese University of Hong Kong Hong Kong China
Citace poskytuje Crossref.org