OBJECTIVE: To test the hypothesis that in recipients of primary prophylactic implantable cardioverter-defibrillators (ICDs), the non-planarity of ECG vector loops predicts (a) deaths despite ICD protection and (b) appropriate ICD shocks. METHODS: Digital pre-implant ECGs were collected in 1948 ICD recipients: 21.4% females, median age 65 years, 61.5% ischaemic heart disease (IHD). QRS and T wave three-dimensional loops were constructed using singular value decomposition that allowed to measure the vector loop planarity. The non-planarity, that is, the twist of the three-dimensional loops out of a single plane, was related to all-cause mortality (n=294; 15.3% females; 68.7% IHD) and appropriate ICD shocks (n=162; 10.5% females; 87.7% IHD) during 5-year follow-up after device implantation. Using multivariable Cox regression, the predictive power of QRS and T wave non-planarity was compared with that of age, heart rate, left ventricular ejection fraction, QRS duration, spatial QRS-T angle, QTc interval and T-peak to T-end interval. RESULTS: QRS non-planarity was significantly (p<0.001) associated with follow-up deaths despite ICD protection with HR of 1.339 (95% CI 1.165 to 1.540) but was only univariably associated with appropriate ICD shocks. Non-planarity of the T wave loop was the only ECG-derived index significantly (p<0.001) associated with appropriate ICD shocks with multivariable Cox regression HR of 1.364 (1.180 to 1.576) but was not associated with follow-up mortality. CONCLUSIONS: The analysed data suggest that QRS and T wave non-planarity might offer distinction between patients who are at greater risk of death despite ICD protection and those who are likely to use the defibrillator protection.
- MeSH
- defibrilátory implantabilní * škodlivé účinky MeSH
- elektrokardiografie metody MeSH
- funkce levé komory srdeční MeSH
- ischemická choroba srdeční * komplikace MeSH
- lidé MeSH
- náhlá srdeční smrt etiologie prevence a kontrola MeSH
- nemoci koronárních tepen * komplikace MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční arytmie diagnóza terapie etiologie MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: In hemodialysis patients, left ventricular hypertrophy (LVH) contributes to high cardiovascular mortality. We examined cardiovascular mortality prediction by the recently proposed Peguero-Lo Presti voltage since it identifies more patients with electrocardiographic (ECG) LVH than Cornell or Sokolow-Lyon voltages. METHODS: A total of 308 patients on hemodialysis underwent 24 h ECG recordings. LVH parameters were measured before and after dialysis. The primary endpoint of cardiovascular mortality was recorded during a median 3-year follow up. Risk prediction was assessed by Cox regression, both unadjusted and adjusted for the Charlson Comorbidity Index and the Cardiovascular Mortality Risk Score. RESULTS: The Peguero-Lo Presti voltage identified with 21% the most patients with positive LVH criteria. All voltages significantly increased during dialysis. Factors such as ultrafiltration rate, Kt/V, body mass index, sex, and phosphate were the most relevant for these changes. During follow-up, 26 cardiovascular deaths occurred. Post-dialysis Peguero-Lo Presti cut-off as well as the Peguero-Lo Presti and Cornell voltages were independently associated with cardiovascular mortality in unadjusted and adjusted analysis. The Sokolow-Lyon voltage was not significantly associated with mortality. An optimal cut-off for the prediction of cardiovascular mortality was estimated at 1.38 mV for the Peguero-Lo Presti. CONCLUSIONS: The post-dialysis Peguero-Lo Presti cut-off as well as the Peguero-Lo Presti and Cornell voltages allowed independent risk prediction of cardiovascular mortality in hemodialysis patients. Measuring the ECG LVH parameters after dialysis might allow a standardized interpretation as dialysis-specific factors influence the voltages.
- MeSH
- dialýza ledvin škodlivé účinky MeSH
- elektrokardiografie MeSH
- hypertenze * MeSH
- hypertrofie levé komory srdeční * diagnóza etiologie MeSH
- index tělesné hmotnosti MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Fragmented QRS complex with visible notching on standard 12-lead electrocardiogram (ECG) is understood to represent depolarization abnormalities and to signify risk of cardiac events. Depolarization abnormalities with similar prognostic implications likely exist beyond visual recognition but no technology is presently suitable for quantification of such invisible ECG abnormalities. We present such a technology. METHODS AND RESULTS: A signal processing method projects all ECG leads of the QRS complex into optimized three perpendicular dimensions, reconstructs the ECG back from this three-dimensional projection, and quantifies the difference (QRS 'micro'-fragmentation, QRS-μf) between the original and reconstructed signals. QRS 'micro'-fragmentation was assessed in three different populations: cardiac patients with automatic implantable cardioverter-defibrillators, cardiac patients with severe abnormalities, and general public. The predictive value of QRS-μf for mortality was investigated both univariably and in multivariable comparisons with other risk factors including visible QRS 'macro'-fragmentation, QRS-Mf. The analysis was made in a total of 7779 subjects of whom 504 have not survived the first 5 years of follow-up. In all three populations, QRS-μf was strongly predictive of survival (P < 0.001 univariably, and P < 0.001 to P = 0.024 in multivariable regression analyses). A similar strong association with outcome was found when dichotomizing QRS-μf prospectively at 3.5%. When QRS-μf was used in multivariable analyses, QRS-Mf and QRS duration lost their predictive value. CONCLUSION: In three populations with different clinical characteristics, QRS-μf was a powerful mortality risk factor independent of several previously established risk indices. Electrophysiologic abnormalities that contribute to increased QRS-μf values are likely responsible for the predictive power of visible QRS-Mf.
- MeSH
- elektrokardiografie * metody MeSH
- lidé MeSH
- prediktivní hodnota testů MeSH
- prognóza MeSH
- rizikové faktory MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- MeSH
- lidé MeSH
- náhlá srdeční smrt * prevence a kontrola MeSH
- srdeční arytmie * komplikace terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Background: Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death. ICD implantation decisions are currently based on reduced left ventricular ejection fraction (LVEF≤35%). However, in some patients, the non-arrhythmic death risk predominates thus diminishing ICD-therapy benefits. Based on previous observations, we tested the hypothesis that compared to the others, patients with nocturnal respiratory rate (NRR) ≥18 breaths per minute (brpm) benefit less from prophylactic ICD implantations. Methods: This prospective cohort study was a pre-defined sub-study of EU-CERT-ICD trial conducted at 44 centers in 15 EU countries between May 12, 2014, and September 6, 2018. Patients with ischaemic or non-ischaemic cardiomyopathy were included if meeting primary prophylactic ICD implantation criteria. The primary endpoint was all-cause mortality. NRR was assessed blindly from pre-implantation 24-hour Holters. Multivariable models and propensity stratification evaluated the interaction between NRR and the ICD mortality effect. This study is registered with ClinicalTrials.gov (NCT0206419). Findings: Of the 2,247 EU-CERT-ICD patients, this sub-study included 1,971 with complete records. In 1,363 patients (61.7 (12) years; 244 women) an ICD was implanted; 608 patients (63.2 (12) years; 108 women) were treated conservatively. During a median 2.5-year follow-up, 202 (14.8%) and 95 (15.6%) patients died in the ICD and control groups, respectively. NRR statistically significantly interacted with the ICD mortality effect (p = 0.0070). While the 1,316 patients with NRR<18 brpm showed a marked ICD benefit on mortality (adjusted HR 0.529 (95% CI 0.376-0.746); p = 0.0003), no treatment effect was demonstrated in 655 patients with NRR≥18 brpm (adjusted HR 0.981 (95% CI 0.669-1.438); p = 0.9202). Interpretation: In the EU-CERT-ICD trial, patients with NRR≥18 brpm showed limited benefit from primary prophylactic ICD implantation. Those with NRR<18 brpm benefitted substantially. Funding: European Community's 7th Framework Programme FP7/2007-2013 (602299).
- Publikační typ
- časopisecké články MeSH
Background: Atrial fibrillation (AF) is common in hemodialysis patients and contributes to increased mortality. We aimed to examine heart rate variability triangular index (HRVI) in hemodialysis patients with AF as it has recently been reported to predict mortality in AF patients without kidney disease. Methods: A total of 88 patients on hemodialysis with a medical history of AF or newly diagnosed AF underwent 24-h electrocardiography recordings. The primary endpoint of cardiovascular mortality was recorded during a median follow up of 3.0 years. Risk prediction was assessed by Cox regression, both unadjusted and adjusted for the Charlson Comorbidity Index and the Cardiovascular Mortality Risk Score. Results: Median age was 76 years, median dialysis vintage was 27 months. Altogether, 22 and 44 patients died due to cardiovascular and non-cardiovascular causes. In 55% of patients AF was present during the recording. Kaplan-Meier plots of HRVI quartiles suggested a non-linear association between HRVI, cardiovascular, and all-cause mortality which was confirmed in non-linear Cox regression analysis. Adjusted linear Cox regression revealed a hazard ratio of 6.2 (95% CI: 2.1-17.7, p = 0.001) and 2.2 (95% CI: 1.3-3.8, p = 0.002) for the outer quartiles (combined first and fourth quartile) for cardiovascular and all-cause mortality, respectively. Patients in the first quartile were more likely to have sinus rhythm whereas patients in the fourth quartile were more likely to have AF. Conclusions: We found a U-shaped association between HRVI and mortality in hemodialysis AF patients. The results might contribute to risk stratification independent of known risk scores in hemodialysis AF patients.
- Publikační typ
- časopisecké články MeSH
AIMS: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value. METHODS AND RESULTS: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non-randomized control group). The primary endpoint is all-cause mortality; the co-primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost-effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12-lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years. CONCLUSIONS: The EU-CERT-ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers.
- MeSH
- defibrilátory implantabilní * MeSH
- dilatační kardiomyopatie komplikace mortalita terapie MeSH
- elektrokardiografie MeSH
- hodnocení rizik * MeSH
- kvalita života MeSH
- lidé MeSH
- míra přežití trendy MeSH
- náhlá srdeční smrt epidemiologie etiologie prevence a kontrola MeSH
- následné studie MeSH
- primární prevence metody MeSH
- prospektivní studie MeSH
- výběr pacientů MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) completed in 2019 will assess this issue. SUMMARY: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicenter observational cohort study done in 44 centers across 15 European countries. A total of 2327 patients with heart failure due to ischemic heart disease or dilated cardiomyopathy indicated for primary prophylactic ICD implantation were recruited between 2014 and 2018 (>1500 patients at first ICD implantation, >750 patients non-randomized non-ICD control group). The primary endpoint was all-cause mortality, and first appropriate shock was co-primary endpoint. At baseline, all patients underwent 12‑lead ECG and Holter-ECG analysis using multiple advanced methods for risk stratification as well as documentation of clinical characteristics and laboratory values. The EU-CERT-ICD data will provide much needed information on the survival benefit of preventive ICD therapy and expand on previous prospective risk stratification studies which showed very good applicability of clinical parameters and advanced risk stratifiers in order to define patient subgroups with above or below average ICD benefit. CONCLUSION: The EU-CERT-ICD study will provide new and current data about effectiveness of primary prophylactic ICD implantation. The study also aims for improved risk stratification and patient selection using clinical risk markers in general, and advanced ECG risk markers in particular.
- MeSH
- defibrilátory implantabilní * MeSH
- elektrokardiografie MeSH
- lidé MeSH
- multicentrické studie jako téma MeSH
- náhlá srdeční smrt * prevence a kontrola MeSH
- pozorovací studie jako téma MeSH
- prospektivní studie MeSH
- srovnávací výzkum účinnosti * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Geografické názvy
- Evropa MeSH