AIMS: Heart failure-related cardiogenic shock (HF-CS) accounts for a significant proportion of CS cases. Whether patients with de novo HF and those with acute-on-chronic HF in CS differ in clinical characteristics and outcome remains unclear. The aim of this study was to evaluate differences in clinical presentation and mortality between patients with de novo and acute-on-chronic HF-CS. METHODS AND RESULTS: In this international observational study, patients with HF-CS from 16 tertiary care centres in five countries were enrolled between 2010 and 2021. To investigate differences in clinical presentation and 30-day mortality, adjusted logistic/Cox regression models were fitted. Patients (n = 1030) with HF-CS were analysed, of whom 486 (47.2%) presented with de novo HF-CS and 544 (52.8%) with acute-on-chronic HF-CS. Traditional markers of CS severity (e.g. blood pressure, heart rate and lactate) as well as use of treatments were comparable between groups. However, patients with acute-on-chronic HF-CS were more likely to have a higher CS severity and also a higher mortality risk, after adjusting for relevant confounders (de novo HF 45.5%, acute-on-chronic HF 55.9%, adjusted hazard ratio 1.38, 95% confidence interval 1.10-1.72, p = 0.005). CONCLUSION: In this large HF-CS cohort, acute-on-chronic HF-CS was associated with more severe CS and higher mortality risk compared to de novo HF-CS, although traditional markers of CS severity and use of treatments were comparable. These findings highlight the vast heterogeneity of patients with HF-CS, emphasize that HF chronicity is a relevant disease modifier in CS, and indicate that future clinical trials should account for this.
- MeSH
- kardiogenní šok * etiologie MeSH
- lidé MeSH
- mortalita v nemocnicích MeSH
- prognóza MeSH
- srdeční selhání * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
BACKGROUND: Currently, use of mechanical circulatory support (MCS) in non-ischaemic cardiogenic shock (CS) is predominantly guided by shock-specific markers, and not by markers of cardiac function. We hypothesise that left ventricular ejection fraction (LVEF) can identify patients with a higher likelihood to benefit from MCS and thus help to optimise their expected benefit. METHODS: Patients with non-ischaemic CS and available data on LVEF from 16 tertiary-care centres in five countries were analysed. Cox regression models were fitted to evaluate the association between LVEF and mortality, as well as the interaction between LVEF, MCS use and mortality. RESULTS: N = 807 patients were analysed: mean age 63 [interquartile range (IQR) 51.5-72.0] years, 601 (74.5%) male, lactate 4.9 (IQR 2.6-8.5) mmol/l, LVEF 20 (IQR 15-30) %. Lower LVEF was more frequent amongst patients with more severe CS, and MCS was more likely used in patients with lower LVEF. There was no association between LVEF and 30-day mortality risk in the overall study cohort. However, there was a significant interaction between MCS use and LVEF, indicating a lower 30-day mortality risk with MCS use in patients with LVEF ≤ 20% (hazard ratio 0.72, 95% confidence interval 0.51-1.02 for LVEF ≤ 20% vs. hazard ratio 1.31, 95% confidence interval 0.85-2.01 for LVEF > 20%, interaction-p = 0.017). CONCLUSION: This retrospective study may indicate a lower mortality risk with MCS use only in patients with severely reduced LVEF. This may propose the inclusion of LVEF as an adjunctive parameter for MCS decision-making in non-ischaemic CS, aiming to optimise the benefit-risk ratio.
- MeSH
- funkce levé komory srdeční MeSH
- kardiogenní šok * diagnóza terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- retrospektivní studie MeSH
- senioři MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. METHODS: This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. RESULTS: We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). CONCLUSIONS: The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. CLINICALTRIALSGOV IDENTIFIER: NCT03752866.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Heart failure-related cardiogenic shock (HF-CS) accounts for a significant proportion of all CS cases. Nevertheless, there is a lack of evidence on sex-related differences in HF-CS, especially regarding use of treatment and mortality risk in women vs. men. This study aimed to investigate potential differences in clinical presentation, use of treatments, and mortality between women and men with HF-CS. METHODS: In this international observational study, patients with HF-CS (without acute myocardial infarction) from 16 tertiary-care centers in five countries were enrolled between 2010 and 2021. Logistic and Cox regression models were used to assess differences in clinical presentation, use of treatments, and 30-day mortality in women vs. men with HF-CS. RESULTS: N = 1030 patients with HF-CS were analyzed, of whom 290 (28.2%) were women. Compared to men, women were more likely to be older, less likely to have a known history of heart failure or cardiovascular risk factors, and lower rates of highly depressed left ventricular ejection fraction and renal dysfunction. Nevertheless, CS severity as well as use of treatments were comparable, and female sex was not independently associated with 30-day mortality (53.0% vs. 50.8%; adjusted HR 0.94, 95% CI 0.75-1.19). CONCLUSIONS: In this large HF-CS registry, sex disparities in risk factors and clinical presentation were observed. Despite these differences, the use of treatments was comparable, and both sexes exhibited similarly high mortality rates. Further research is necessary to evaluate if sex-tailored treatment, accounting for the differences in cardiovascular risk factors and clinical presentation, might improve outcomes in HF-CS.
- MeSH
- funkce levé komory srdeční MeSH
- kardiogenní šok * diagnóza epidemiologie etiologie MeSH
- lidé MeSH
- mortalita v nemocnicích MeSH
- sexuální faktory MeSH
- srdeční selhání * diagnóza epidemiologie terapie MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
AIMS: Despite its high incidence and mortality risk, there is no evidence-based treatment for non-ischaemic cardiogenic shock (CS). The aim of this study was to evaluate the use of mechanical circulatory support (MCS) for non-ischaemic CS treatment. METHODS AND RESULTS: In this multicentre, international, retrospective study, data from 890 patients with non-ischaemic CS, defined as CS due to severe de-novo or acute-on-chronic heart failure with no need for urgent revascularization, treated with or without active MCS, were collected. The association between active MCS use and the primary endpoint of 30-day mortality was assessed in a 1:1 propensity-matched cohort. MCS was used in 386 (43%) patients. Patients treated with MCS presented with more severe CS (37% vs. 23% deteriorating CS, 30% vs. 25% in extremis CS) and had a lower left ventricular ejection fraction at baseline (21% vs. 25%). After matching, 267 patients treated with MCS were compared with 267 patients treated without MCS. In the matched cohort, MCS use was associated with a lower 30-day mortality (hazard ratio 0.76, 95% confidence interval 0.59-0.97). This finding was consistent through all tested subgroups except when CS severity was considered, indicating risk reduction especially in patients with deteriorating CS. However, complications occurred more frequently in patients with MCS; e.g. severe bleeding (16.5% vs. 6.4%) and access-site related ischaemia (6.7% vs. 0%). CONCLUSION: In patients with non-ischaemic CS, MCS use was associated with lower 30-day mortality as compared to medical therapy only, but also with more complications. Randomized trials are needed to validate these findings.
- MeSH
- funkce levé komory srdeční MeSH
- intraaortální balónková pumpa metody MeSH
- kardiogenní šok etiologie terapie MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- retrospektivní studie MeSH
- srdeční selhání * komplikace MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
A total of 1001 subjects (82.0 years, 62.5% female, 63.7% NYHA III/IV at baseline) with severe aortic stenosis at high surgical risk were enrolled in the prospective CONFIDENCE registry and treated with a PorticoTM transcatheter heart valve (THV) using either a first-generation delivery system (DS) or the FlexNavTM DS. The objective of this registry is to characterize the procedural safety and device performance of the PorticoTM THV at 30 days. The study collected 'standard-of-care' clinical and device performance data, with adverse events adjudicated by an independent clinical event committee according to the Valve Academic Research Consortium-2 criteria. The implantation of a single PorticoTM THV was successful in 97.5% of subjects. The 30-day all-cause mortality, cardiovascular mortality, and disabling stroke rates were 2.6%, 2.1%, and 1.8%, respectively. A new pacemaker was implanted in 19.0% of subjects at 30 days. At 30 days, the effective orifice area and mean gradient values were 1.82 cm2 and 7.1 mmHg, respectively. The 30-day rate of moderate paravalvular leak (PVL) was 2.1%, with no occurrence of severe PVL. The PorticoTM THV demonstrated improved hemodynamic performance and low rates of safety events at 30 days in a large cohort of subjects implanted with the PorticoTM THV with either the first-generation DS or FlexNavTM DS.
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: The purpose of this study is to report the 1-year results of the CENTERA-EU trial. BACKGROUND: The CENTERA transcatheter heart valve (THV) (Edwards Lifesciences, Irvine, California) is a low-profile (14-F eSheath compatible), self-expanding nitinol valve, with a motorized delivery system allowing for repositionability. The 30-day results of the CENTERA-EU trial demonstrated the short-term safety and effectiveness of the valve. METHODS: Implantations were completed in 23 centers in Europe, Australia, and New Zealand. Transfemoral access was used in all patients. Echocardiographic outcomes were adjudicated by a core laboratory at baseline, discharge, 30 days, 6 months, and 1 year. Major adverse clinical events were adjudicated by an independent clinical events committee. RESULTS: Between March 2015 and July 2016, 203 high-risk patients (age 82.7 ± 5.5 years, 67.5% women, 68.0% New York Heart Association functional class III or IV, Society of Thoracic Surgeons score 6.1 ± 4.2%) with severe, symptomatic aortic stenosis underwent transcatheter aortic valve replacement with the CENTERA THV. The primary endpoint of the study was 30-day mortality (1.0%). At 1 year, overall mortality was 9.1%, cardiovascular mortality was 4.6%, disabling stroke was 4.1%, new permanent pacemakers were implanted in 6.5% of patients at risk, and cardiac-related rehospitalization was 6.8%. Hemodynamic parameters were stable at 1 year, with a mean aortic valve gradient of 8.1 ± 4.7 mm Hg, a mean effective orifice area of 1.7 ± 0.42 cm2, and no incidences of severe or moderate aortic regurgitation. CONCLUSIONS: The CENTERA-EU trial demonstrated mid-term safety and effectiveness of the CENTERA THV, with low mortality, sustained improvements in hemodynamic performances, and low incidence of permanent pacemaker implantations in high-risk patients with symptomatic aortic stenosis. (Safety and Performance of the Edwards CENTERA-EU Self-Expanding Transcatheter Heart Valve [CENTERA-2]; NCT02458560).
- MeSH
- aortální chlopeň diagnostické zobrazování patofyziologie chirurgie MeSH
- aortální stenóza diagnostické zobrazování mortalita patofyziologie chirurgie MeSH
- bioprotézy * MeSH
- časové faktory MeSH
- lidé MeSH
- obnova funkce MeSH
- pooperační komplikace mortalita terapie MeSH
- prospektivní studie MeSH
- protézy - design MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční chlopně umělé * MeSH
- stupeň závažnosti nemoci MeSH
- transkatetrální implantace aortální chlopně škodlivé účinky přístrojové vybavení mortalita MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Austrálie MeSH
- Evropa MeSH
- Nový Zéland MeSH
BACKGROUND: We hypothesized that fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) would be superior to medical therapy as initial treatment in patients with stable coronary artery disease. METHODS: Among 1220 patients with angiographically significant stenoses, those in whom at least one stenosis was hemodynamically significant (FFR, ≤0.80) were randomly assigned to FFR-guided PCI plus medical therapy or to medical therapy alone. Patients in whom all stenoses had an FFR of more than 0.80 received medical therapy and were entered into a registry. The primary end point was a composite of death, myocardial infarction, or urgent revascularization. RESULTS: A total of 888 patients underwent randomization (447 patients in the PCI group and 441 in the medical-therapy group). At 5 years, the rate of the primary end point was lower in the PCI group than in the medical-therapy group (13.9% vs. 27.0%; hazard ratio, 0.46; 95% confidence interval [CI], 0.34 to 0.63; P<0.001). The difference was driven by urgent revascularizations, which occurred in 6.3% of the patients in the PCI group as compared with 21.1% of those in the medical-therapy group (hazard ratio, 0.27; 95% CI, 0.18 to 0.41). There were no significant differences between the PCI group and the medical-therapy group in the rates of death (5.1% and 5.2%, respectively; hazard ratio, 0.98; 95% CI, 0.55 to 1.75) or myocardial infarction (8.1% and 12.0%; hazard ratio, 0.66; 95% CI, 0.43 to 1.00). There was no significant difference in the rate of the primary end point between the PCI group and the registry cohort (13.9% and 15.7%, respectively; hazard ratio, 0.88; 95% CI, 0.55 to 1.39). Relief from angina was more pronounced after PCI than after medical therapy. CONCLUSIONS: In patients with stable coronary artery disease, an initial FFR-guided PCI strategy was associated with a significantly lower rate of the primary composite end point of death, myocardial infarction, or urgent revascularization at 5 years than medical therapy alone. Patients without hemodynamically significant stenoses had a favorable long-term outcome with medical therapy alone. (Funded by St. Jude Medical and others; FAME 2 ClinicalTrials.gov number, NCT01132495 .).
- MeSH
- angina pectoris terapie MeSH
- antihypertenziva terapeutické užití MeSH
- frakční průtoková rezerva myokardu * MeSH
- infarkt myokardu epidemiologie prevence a kontrola MeSH
- inhibitory agregace trombocytů terapeutické užití MeSH
- Kaplanův-Meierův odhad MeSH
- koronární angioplastika * MeSH
- koronární nemoc farmakoterapie mortalita terapie MeSH
- koronární stenóza farmakoterapie patofyziologie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- opakovaná terapie statistika a číselné údaje MeSH
- senioři MeSH
- stenty uvolňující léky MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH