Long-term measurements using silicon radiation spectrometer Liulin on board commercial aircraft have been performed since 2001; results were put into a new database, which covers more than 4500 flights with more than 130 000 measurements. Methodology and tools were developed to normalize the data with respect to latitude and altitude and thus enable comparison with other radiation detectors and with model calculations. This capability is demonstrated using data from the neutron monitor at Lomnický štít. Instead of providing data files for individual measurement period, two software solutions are delivered. First is a web-based user interface for visualizing and downloading arbitrary time window of interest from the database hosted at http://cr10.odz.ujf.cas.cz. The second is a set of interactive Python notebooks available at GitHub. Those implement the calibration, normalization and visualization methods-so the outputs can be tailored to user needs. The software and data are provided under GNU/CC license.
- MeSH
- databáze faktografické MeSH
- dávka záření MeSH
- internet MeSH
- kalibrace MeSH
- kosmické záření * MeSH
- křemík chemie MeSH
- letadla * MeSH
- letecké a kosmické lékařství MeSH
- letectví MeSH
- monitorování radiace statistika a číselné údaje MeSH
- nadmořská výška * MeSH
- neutrony * MeSH
- radiační expozice MeSH
- sluneční aktivita MeSH
- software MeSH
- zeměpis MeSH
- Publikační typ
- časopisecké články MeSH
In order to increase the early warning ability of the radiation monitoring network of the Czech republic, a high-volume aerosol sampler was upgraded with a NaI(Tl) probe placed directly above the aerosol filter. The paper demonstrates the possibility of using a method based on principal component regression to accurately subtract the complicated natural background caused by radon decay products. This approach yielded minimum detectable activities of 8mBq/m3, 3mBq/m3 and 7mBq/m3 for 131I, 134Cs and 137Cs, respectively, after 24h of sampling.
- MeSH
- aerosoly MeSH
- algoritmy MeSH
- analýza hlavních komponent MeSH
- jodidy MeSH
- lidé MeSH
- monitorování radiace přístrojové vybavení metody statistika a číselné údaje MeSH
- radioaktivní látky znečišťující vzduch analýza MeSH
- radioizotopy cesia analýza MeSH
- radioizotopy jodu analýza MeSH
- regresní analýza MeSH
- sodík MeSH
- spektrometrie gama přístrojové vybavení metody statistika a číselné údaje MeSH
- thallium MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
Cíl: CT fluoroskopie (CTF) představuje bezpečný a efektivní způsob pro provádění perkutánních intervenčních výkonů. Hlavním problémem při jejím používání je relativně vysoká radiační zátěž. Cílem pilotní studie bylo zmapovat dávky radiologů i pacientů a dále prozkoumat metody jejich optimalizace při použití různých typů ochranných pomůcek. Metodika: Pro každou jednotlivou intervenci při CTF byla měřena kumulativní dávka na ruku radiologa pomocí přímo odečítajícího dozimetru Unfors EDD umístěného na dorzální straně ruky lékaře. Dále bylo provedeno měření na vodním fantomu s cílem určit potenciál ochranných rukavic a roušek. Pomocí ionizační komory a dozimetrického systému RADCAL byla stanovena kumulativní dávka na ruce i na tělo radiologa při CTF při různém použití těchto ochranných pomůcek. Pro přehled o radiační zátěži pacientů při CTF byly stanoveny místní diagnostické referenční úrovně pro nejčastěji prováděná vyšetření podle postupu popsaného v Národních radiologických standardech pro radiologickou fyziku z dedikovaného CT přístroje. Získaná data byla následně podrobena analýze s cílem zjistit korelaci mezi dávkovými parametry. Výsledky: Ze sledovaných výkonů představuje nejmenší dávkovou zátěž rukou intervenujícího lékaře periradikulární terapie. Biopsie i drenáže jsou dávkově 3-4krát náročnější. Nejúčinnější ochrannou pomůckou pro snížení ozáření ruky intervenujícího radiologa používajícího CTF je zapnutí softwarové ochrany. Rukavice dávku ještě snižují o dalších cca 8 %. Použití roušky snižuje ozáření těla intervenujícího radiologa o 15 %. Studie ukázala, že pacientská dávková data se v průběhu času příliš nemění. Díky neexistenci národních úrovní není možné získané MDRÚ porovnat s jinými referenčními hodnotami v rámci republiky. Analýza dat ukázala, že při intervenčním zákroku a CTF představuje preintervenční a postintervenční sken více než 2/3 radiační zátěže pacienta. Závěr: Intervence prováděné pod CT kontrolou jsou rychlé, efektivní a miniinvazivní diagnostické či léčebné zákroky. I když je CTF relativně dávkově náročnější metoda, dávky lze optimalizovat správnou volbou expozičních parametrů a použitím vhodných ochranných pomůcek.
Aim: CT fluoroscopy (CTF) is a safe and effective method for performing percutaneous interventional procedures. The main problem with its use is relatively high radiation burden. The aim of this pilot study was to map doses to the radiologists and patient doses and to explore different methods of optimizing the use of various types of protection devices. Methodology: For each individual intervention using CTF cumulative dose to the radiologists hand was measured using the direct dosimeter Unfors EDD The dosimetr was located on the dorsal side of the interventionalists hand. Furthermore, measurements were taken using water phantom in order to identify potential use of protective gloves and pads. We used the dosimetric system RADCAL with ionisation chamber and measured cumulative dose to the hands and the body radiologist CTF under various circumstances with different protective device used. For an overview of the radiation exposure of patients during CTF we established local diagnostic reference levels for the most commonly performed procedures. The process was in accordinance with National Radiological Standards for Radiological Physics. We had data from two dedicated CT devices. The dose data obtained were further analyzed to determine the correlation between the dose and other exposure parametrs. Results: Among the monitored interventional procedures with CTF the periradicular therapy is associated with the smallest dose to the hands of the interventionalist. Biopsies and drainages are associated with doses 3-4 times higher. The most effective protective equipment for hand exposure reduction while using CTF is use the software protection. Protective gloves even further reduced the dose by about 8%. Using masks reduces body irradiation intervening radiologist by 15%. The study showed that patient dose data does not change much over time. Due to the absence of national reference levels, obtained local DRLs cannot be compared with other benchmarks in the republic. Data analysis showed that the intervention procedure under CTF, the pre-intervention and post-intervention scan represents more than % of the radiation load to the patient. Conclusion: Interventions performed under CT guidance are fast, efficient and minimally invasive diagnostic or therapeutic procedures. Although the CTF is relatively high dose method, the dose can be optimized by selecting the correct exposure parametrs and proper use of an appropriate protective equipment.
- Klíčová slova
- RADPAD,
- MeSH
- fluoroskopie MeSH
- hygiena práce normy MeSH
- intervenční radiografie metody statistika a číselné údaje MeSH
- lidé MeSH
- monitorování radiace * statistika a číselné údaje MeSH
- obsah radioaktivních látek v organizmu * MeSH
- ochranné rukavice MeSH
- radiační expozice prevence a kontrola MeSH
- radiační ochrana * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- hodnotící studie MeSH
This paper presents the results of atmospheric radioactivity monitoring over the Czech Republic, as obtained by the Radiation Monitoring Network, following the Fukushima Dai-Ichi Nuclear Power Plant accident. Maximum values for (131)I were 5.6 mBq m(-3) in aerosol form and 13 mBq m(-3) in gaseous form. The maximum values for (134)Cs and (137)Cs were 0.64 and 0.72 mBq m(-3), respectively. The estimated effective half-time for removing the activity from the atmosphere was 6-7 d and 3.5 d for caesium and iodine, respectively. The gaseous-to-total activity ratios of (131)I ranged between 0.3 and 0.9, with an arithmetic mean value of 0.77. The mean value for the (134)Cs/(137)Cs ratios was close to 1.0. The effective inhalation dose due to the accident for an adult living in the Czech Republic was estimated at <4 × 10(-5) mSv, out of which the proportion of (131)I was 88%.
- MeSH
- atmosféra chemie MeSH
- havárie elektrárny Fukušima * MeSH
- hodnocení rizik MeSH
- lidé MeSH
- monitorování radiace metody statistika a číselné údaje MeSH
- obsah radioaktivních látek v organizmu MeSH
- poločas MeSH
- radioaktivní znečištění ovzduší analýza statistika a číselné údaje MeSH
- radionuklidy analýza MeSH
- vystavení vlivu životního prostředí analýza statistika a číselné údaje MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
The article reports results from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDI vol) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: <1 y, >1-5 y, >5-10 y and >10-15 y. CTDIw, CTDI vol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75th percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDI vol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided.
- MeSH
- dávka záření MeSH
- dítě MeSH
- internacionalita MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- monitorování radiace normy statistika a číselné údaje MeSH
- novorozenec MeSH
- pediatrie normy MeSH
- počítačová rentgenová tomografie normy statistika a číselné údaje MeSH
- předškolní dítě MeSH
- průzkumy zdravotní péče MeSH
- radiační expozice normy statistika a číselné údaje MeSH
- referenční hodnoty MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- MeSH
- dávka záření MeSH
- fantomy radiodiagnostické MeSH
- financování organizované MeSH
- lidé MeSH
- monitorování radiace metody přístrojové vybavení statistika a číselné údaje MeSH
- náhlé příhody klasifikace MeSH
- nukleární lékařství - oddělení nemocnice statistika a číselné údaje MeSH
- radiační poranění klasifikace MeSH
- radioizotopy cesia MeSH
- radioizotopy kobaltu MeSH
- radiometrie metody statistika a číselné údaje MeSH
- Check Tag
- lidé MeSH
- MeSH
- dávka záření MeSH
- jaderné elektrárny MeSH
- lidé MeSH
- monitorování radiace statistika a číselné údaje MeSH
- únik radioaktivních látek MeSH
- Check Tag
- lidé MeSH
- Geografické názvy
- Maďarsko MeSH
- Rakousko MeSH
- Slovenská republika MeSH
- MeSH
- bismut MeSH
- dávka záření MeSH
- dítě MeSH
- kongresy jako téma MeSH
- lidé MeSH
- monitorování radiace statistika a číselné údaje MeSH
- ochranné prostředky očí MeSH
- počítačová rentgenová tomografie statistika a číselné údaje škodlivé účinky MeSH
- radiační ochrana metody MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- Publikační typ
- přednášky MeSH
- Geografické názvy
- Slovenská republika MeSH
A widely discussed question is how much a nuclear power plant really contributes to irradiation of the people living in its vicinity. A number of laboratory and in situ measurements were performed in the area surrounding NPP Temelin, on the basis of which we can specify the irradiation of this area from various sources. The evaluation includes the contributions from natural sources, such as radon, terrestrial radiation and cosmic radiation, together with the contribution from inhalation and ingestion of radionuclides. Medical irradiation and nuclear fallout are also included.
- MeSH
- jaderné elektrárny statistika a číselné údaje MeSH
- lidé MeSH
- monitorování radiace statistika a číselné údaje MeSH
- obsah radioaktivních látek v organizmu MeSH
- radiační pozadí MeSH
- vystavení vlivu životního prostředí analýza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
- MeSH
- hygiena záření organizace a řízení přístrojové vybavení statistika a číselné údaje MeSH
- ionizující záření MeSH
- jaderné elektrárny MeSH
- monitorování radiace statistika a číselné údaje MeSH
- radioaktivní kontaminace potravin analýza statistika a číselné údaje MeSH
- radioaktivní látky znečišťující půdu analýza MeSH
- radioaktivní spad statistika a číselné údaje MeSH
- radioaktivní znečištění ovzduší analýza statistika a číselné údaje MeSH
- radioaktivní znečištění vody analýza statistika a číselné údaje MeSH
- Geografické názvy
- Česká republika MeSH