Older individuals experience cardiovascular dysfunction during extended bedridden hospital or care home stays. Bed rest is also used as a model to simulate accelerated vascular deconditioning occurring during spaceflight. This study investigates changes in retinal microcirculation during a ten-day bed rest protocol. Ten healthy young males (22.9 ± 4.7 years; body mass index: 23.6 ± 2.5 kg·m-2) participated in a strictly controlled repeated-measures bed rest study lasting ten days. High-resolution images were obtained using a hand-held fundus camera at baseline, daily during the 10 days of bed rest, and 1 day after re-ambulation. Retinal vessel analysis was performed using a semi-automated software system to obtain metrics for retinal arteriolar and venular diameters, central retinal artery equivalent and central retinal vein equivalent, respectively. Data analysis employed a mixed linear model. At the end of the bed rest period, a significant decrease in retinal venular diameter was observed, indicated by a significantly lower central retinal vein equivalent (from 226.1 μm, CI 8.90, to 211.4 μm, CI 8.28, p = .026), while no significant changes in central retinal artery equivalent were noted. Prolonged bed rest confinement resulted in a significant (up to 6.5%) reduction in retinal venular diameter. These findings suggest that the changes in retinal venular diameter during bedrest may be attributed to plasma volume losses and reflect overall (cardio)-vascular deconditioning.
- MeSH
- arteria centralis retinae * diagnostické zobrazování MeSH
- fluoresceinová angiografie MeSH
- klid na lůžku škodlivé účinky MeSH
- lidé MeSH
- retinální cévy diagnostické zobrazování MeSH
- vena centralis retinae * diagnostické zobrazování MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Theoretical models of retinal hemodynamics showed the modulation of retinal pulsatile patterns (RPPs) by heart rate (HR), yet in-vivo validation and scientific merit of this biological process is lacking. Such evidence is critical for result interpretation, study design, and (patho-)physiological modeling of human biology spanning applications in various medical specialties. In retinal hemodynamic video-recordings, we characterize the morphology of RPPs and assess the impact of modulation by HR or other variables. Principal component analysis isolated two RPPs, i.e., spontaneous venous pulsation (SVP) and optic cup pulsation (OCP). Heart rate modulated SVP and OCP morphology (pFDR < 0.05); age modulated SVP morphology (pFDR < 0.05). In addition, age and HR demonstrated the effect on between-group differences. This knowledge greatly affects future study designs, analyses of between-group differences in RPPs, and biophysical models investigating relationships between RPPs, intracranial, intraocular pressures, and cardiovascular physiology.
- MeSH
- discus nervi optici * MeSH
- lidé MeSH
- nitrooční tlak MeSH
- pulzatilní průtok fyziologie MeSH
- srdeční frekvence MeSH
- vena centralis retinae * fyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: To evaluate the relationship between the ischemic index and the oxygen saturation in retinal vessels in patients with retinal vein occlusion. DESIGN: Prospective, cross-sectional study. METHODS: We performed a prospective study. The cohort consisted of 43 eyes of 43 patients with retinal vein occlusions (RVO), 23 of whom had central retinal vein occlusions (CRVO) and 20 who had branch retinal vein occlusions (BRVO). We evaluated the retinal vessel saturation using an automatic retinal oximetry device. The retinal ischemic index (ISI) was determined using ultra-widefield fluorescein angiography. RESULTS: Mean arterial saturation (±SD) was 100% ± 11%, mean vein saturation was 52% ±13%, and mean A-V difference was 48% ± 16% in eyes with BRVO. The average ISI in the same group was 0.48 (range 0-1). There was no statistically significant correlation between the retinal ischemic index and retinal saturation in the BRVO group. The affected eye in the CRVO group had a mean arterial saturation of 101% ± 6%, vein saturation of 44% ± 11 % and A-V difference of 58% ± 10%. The average ISI in the CRVO group was 0.54 (range 0-1). A statistically significant negative correlation between ISI and vein saturation was found in the CRVO group (r = -0.686; P =.0003). A significant positive correlation between ISI and the A-V difference was found in the CRVO group (r = 0.893; P <.0001). CONCLUSIONS: Oxygen saturation in the retinal vein and the arteriovenous difference correlated with the ischemic index in CRVO patients. No correlation was found for BRVO patients.
- MeSH
- fluoresceinová angiografie MeSH
- ischemie patofyziologie MeSH
- kyslík krev MeSH
- lidé středního věku MeSH
- lidé MeSH
- okluze retinální žíly patofyziologie MeSH
- optická koherentní tomografie MeSH
- oxymetrie MeSH
- prospektivní studie MeSH
- průřezové studie MeSH
- senioři MeSH
- spotřeba kyslíku fyziologie MeSH
- vena centralis retinae fyziologie MeSH
- zraková ostrost MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
[Intracranial pressure evaluation by ophthalmologist]
Hodnota IKT má význam pri diagnostike niektorých ochorení oka a očnice. Metódy pre priame meranie intrakraniálneho tlaku (IKT) sú exaktné, ale sú invazívne a je určité riziko infekcie a poškodenia tkanív. V súčasnosti sú preukazné 2 nepriame metódy: Digitálna oftalmodynamometria (D-ODM) a Transkraniálna Doppler ultrasonografia (TDU). D-ODM je neinvazívna metóda na meranie venózneho pulzačného tlaku (VPT). VPT získame hodnotením pulzačných fenoménov. Za fyziologických podmienok (aby bol zachovaný prietok krvi) VPT nemôže byť nižší ako IKT a intraorbitálny tlak (IorbitT). Ak úmyselne zvýšime VPT tak, aby sa vyrovnal súčasnému IKT alebo IorbitT – dochádza k pulzácii VCR. Aproximatívny IKT vypočítame kalkuláciou VPT vo vzorci: IKT = 0,903 - (VPT) - 8,87, alebo IKT = 0,29 + 0,74 (VOT / PI (AO )). [VOT = vnútroočný tlak. PI – Index pulzatility arteriae ophthalmicae získame pomocou farebnej Doppler ultrasonografie]. Výpočet približného IKT je možné aj pomocou matematických vzorcov: IKT = 0.55 × BMI index (kg/m2) + 0.16 × KTD (mmHg) – 0,18 × age (roky) – 1,91. [ KTD – diastolický krvný tlak , BMI – Body masters index], alebo: IKT = 16,95 x OSASW09 + 0,39 x BMI + 0,14 + TKS – 20,90 [OSASW095: šírka orbitálneho subarachnoideálneho priestoru vo vzdialenosti 9 mm za bulbom (vyšetrenie nukleárnej magnetickej rezonancie), BMI: Body mass index, TKS: stredný arteriálny tlak.] Fyziologické hodnoty VPT sú do 15 torr. Nad 20 torr. je už riziko zvýšenia intrakraniálneho tlaku. Fyziologický vnútroočný tlak je nižší než VPT o cca 5 torr. Záver: D-ODM je užitočnou skríningovou metódou pri hodnotení IKT v rámci diagnostiky hydrocefalu, mozgových tumorov, mozgových krvácaní a po mozgovej traume a tiež pri očných ochoreniach: glaukómy (okulárna hypertenzia), orbitopatie (endokrinná orbitopatia), ischemická / neischemická oklúzia ciev oka, nepriama detekcia IKT, karotído-kavernózna fistula, amaurosis fugax, neuropatie zrakového nervu. D-ODM je relevantná pre okamžité vyhodnotenie IKT, ale nie je vhodná pre kontinuálne monitorovanie. Vzhľadom k tomu, že sa môže opakovať, je vhodná pri kontrolách pacienta s podozrením na zvýšený IKT.
The value of ICT is important in diagnosis of the diseases of the eye and orbit Methods for direct measurement of intracranial pressure (ICT) are exact, but they are invasive and there is some risk of infection and damage of the tissue. Currently there are 2 valid indirect methods of mesurement of IKT. Digital Ophthalmodynamometry (D-ODM) and Transcranial Doppler ultrasonography (TDU). D-ODM is a non-invasive method for measuring of the Pulsating Venous Pressure (VPT). We can measure VPT by the pulse phenomena. Physiologically (to be maintained blood flow) VPT not be less than the ICT and intraorbital pressure (IorbitT). If we raise the VPT to compensate the current IKT (or IorbitT) - there is a pulsation VCR. We can calculate aproxymative IKT with the formula: IKT = 0.903 - (VPT) - 8.87, or IKT = 0.29 + 0.74 (VOT / PI (AO)). [VOT = intraocular pressure. PI – pulsatility index arteriae ophthalmic from Color Doppler ultrasonography.] IKT can be approximate calculate with mathematical formulas: IKT = 0:55 × BMI (kg / m2) + 0.16 × KTD (mmHg) - 0:18 x age (years) - 1.91. [KTD - diastolic blood pressure, BMI - Body master index] or: IKT = 16.95 x 0.39 x OSASW09 + BMI + 0.14 + TKS - 20.90. [OSASW095: width of the orbital arachnoid space at a distance of 9 mm behind the eyeball (nuclear magnetic resonance). BMI: Body Mass Index. TKS: mean arterial pressure]. Normal values of VPT are under 15 torr. The risk of increased intracranial pressure is above 20 torr. Under physiological conditions, there is intraocular pressure lower in about 5 torr than VPT. Conclusion: D-ODM is a useful screening method in the evaluation of IKT for hydrocephalus, brain tumors, cerebral hemorrhage after brain trauma and also in ocular diseases: Glaucoma, Ocular hypertension, orbitopathy (endocrine orbitopathy), ischemic / non-ischemic occlusion of blood vessels of the eye, indirect detection ICT carotid artery-cavernous fistula, amaurosis fugax, optic neuropathy. D-ODM is suitable for immediate evaluation of IKT, but is not suitable for continuous monitoring. As it can be repeated, it is useful for a patient suspected of having an increased ICT.
- Klíčová slova
- venózní pulzační tlak, venózní odtokový tlak, retinální venózní tlak,
- MeSH
- arteria renalis diagnostické zobrazování MeSH
- intrakraniální tlak MeSH
- nitrooční tlak MeSH
- oftalmodynamometrie * metody MeSH
- ultrasonografie dopplerovská barevná MeSH
- ultrasonografie dopplerovská transkraniální MeSH
- vena centralis retinae diagnostické zobrazování MeSH
- venózní tlak MeSH
The value of ICT is important in diagnosis of the diseases of the eye and orbit Methods for direct measurement of intracranial pressure (ICT) are exact, but they are invasive and there is some risk of infection and damage of the tissue. Currently there are 2 valid indirect methods of mesurement of IKT. Digital Ophthalmodynamometry (D-ODM) and Transcranial Doppler ultrasonography (TDU). D-ODM is a non-invasive method for measuring of the Pulsating Venous Pressure (VPT). We can measure VPT by the pulse phenomena. Physiologically (to be maintained blood flow) VPT not be less than the ICT and intraorbital pressure (IorbitT). If we raise the VPT to compensate the current IKT (or IorbitT) - there is a pulsation VCR. We can calculate aproxymative IKT with the formula: IKT = 0.903 - (VPT) - 8.87, or IKT = 0.29 + 0.74 (VOT / PI (AO)). [VOT = intraocular pressure. PI – pulsatility index arteriae ophthalmic from Color Doppler ultrasonography.] IKT can be approximate calculate with mathematical formulas: IKT = 0:55 × BMI (kg / m2) + 0.16 × KTD (mmHg) - 0:18 x age (years) - 1.91. [KTD - diastolic blood pressure, BMI - Body master index] or: IKT = 16.95 x 0.39 x OSASW09 + BMI + 0.14 + TKS - 20.90. [OSASW095: width of the orbital arachnoid space at a distance of 9 mm behind the eyeball (nuclear magnetic resonance). BMI: Body Mass Index. TKS: mean arterial pressure]. Normal values of VPT are under 15 torr. The risk of increased intracranial pressure is above 20 torr. Under physiological conditions, there is intraocular pressure lower in about 5 torr than VPT. Conclusion: D-ODM is a useful screening method in the evaluation of IKT for hydrocephalus, brain tumors, cerebral hemorrhage after brain trauma and also in ocular diseases: Glaucoma, Ocular hypertension, orbitopathy (endocrine orbitopathy), ischemic / non-ischemic occlusion of blood vessels of the eye, indirect detection ICT carotid artery-cavernous fistula, amaurosis fugax, optic neuropathy. D-ODM is suitable for immediate evaluation of IKT, but is not suitable for continuous monitoring. As it can be repeated, it is useful for a patient suspected of having an increased ICT.
- Klíčová slova
- venózní pulzační tlak, venózní odtokový tlak, retinální venózní tlak,
- MeSH
- arteria renalis diagnostické zobrazování MeSH
- intrakraniální tlak MeSH
- nitrooční tlak MeSH
- oftalmodynamometrie * metody MeSH
- ultrasonografie dopplerovská barevná MeSH
- ultrasonografie dopplerovská transkraniální MeSH
- vena centralis retinae diagnostické zobrazování MeSH
- venózní tlak MeSH
- MeSH
- arterioly chirurgie MeSH
- fotokoagulace metody MeSH
- glaukom neovaskulární etiologie farmakoterapie komplikace MeSH
- ischemie komplikace MeSH
- kardiovaskulární nemoci farmakoterapie komplikace prevence a kontrola MeSH
- laserová koagulace metody MeSH
- lidé MeSH
- makulární edém epidemiologie farmakoterapie komplikace MeSH
- monoklonální protilátky terapeutické užití MeSH
- okluze retinální žíly * diagnóza patofyziologie terapie MeSH
- prognóza MeSH
- rizikové faktory MeSH
- vaskulární endoteliální růstové faktory antagonisté a inhibitory terapeutické užití MeSH
- věkové faktory MeSH
- vena centralis retinae patofyziologie patologie účinky léků MeSH
- zraková ostrost fyziologie účinky léků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- směrnice pro lékařskou praxi MeSH
- MeSH
- arterioly chirurgie MeSH
- fotokoagulace metody MeSH
- glaukom neovaskulární etiologie farmakoterapie komplikace MeSH
- ischemie komplikace MeSH
- kardiovaskulární nemoci farmakoterapie komplikace prevence a kontrola MeSH
- laserová koagulace metody MeSH
- lidé MeSH
- makulární edém epidemiologie farmakoterapie komplikace MeSH
- monoklonální protilátky terapeutické užití MeSH
- okluze retinální žíly * diagnóza patofyziologie terapie MeSH
- prognóza MeSH
- rizikové faktory MeSH
- vaskulární endoteliální růstové faktory antagonisté a inhibitory terapeutické užití MeSH
- věkové faktory MeSH
- vena centralis retinae patofyziologie patologie účinky léků MeSH
- zraková ostrost fyziologie účinky léků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- směrnice pro lékařskou praxi MeSH
- MeSH
- arteria centralis retinae ultrasonografie MeSH
- glaukom s otevřeným úhlem diagnóza patofyziologie MeSH
- lidé MeSH
- nemoci orbity diagnóza ultrasonografie MeSH
- oči krevní zásobení patologie MeSH
- ultrasonografie dopplerovská barevná metody přístrojové vybavení využití MeSH
- vena centralis retinae ultrasonografie MeSH
- Check Tag
- lidé MeSH
Autori opisujú štyri prípady vzácnej a doteraz málo poznanej anomálie výstupu kmeňa centrálnej vény sietnice na terči zrakového nervu. Všetky sa vyskytli na myopickou oku stredných refrakčných hodnôt. Obehové poruchy sietnicovej a cievovkovej cirkulácie sa nezaznamenali.
The authors describe four cases of rare and yet little known anomaly of the central retinal vein trunc exit on optical disc. All the anomalies occured in myopic eyes with higher refractive errors. They did not cause of any retinal and choroidal vascular disturbances.
- MeSH
- dítě MeSH
- fluoresceinová angiografie MeSH
- lidé středního věku MeSH
- lidé MeSH
- myopie MeSH
- nervus opticus krevní zásobení MeSH
- retina inervace krevní zásobení patologie MeSH
- retinální cévy abnormality MeSH
- vena centralis retinae abnormality ultrasonografie MeSH
- Check Tag
- dítě MeSH
- lidé středního věku MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH