OBJECTIVE: Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS: We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS: We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS: Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.
- MeSH
- břicho chirurgie MeSH
- dospělí MeSH
- kontinuální monitorování glukózy MeSH
- krevní glukóza * analýza MeSH
- kritický stav * MeSH
- lidé středního věku MeSH
- lidé MeSH
- monitorování fyziologických funkcí metody MeSH
- senioři MeSH
- studie proveditelnosti MeSH
- transplantace orgánů MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: This paper describes the development of a mobile app for diabetes mellitus (DM) control and self-management and presents the results of long-term usage of this system in the Czech Republic. DM is a chronic disease affecting large numbers of people worldwide, and this number is continuously increasing. There is massive potential to increase adherence to self-management of DM with the use of smartphones and digital therapeutics interventions. OBJECTIVE: This study aims to describe the process of development of a mobile app, called Mobiab, for DM management and to investigate how individual features are used and how the whole system benefits its long-term users. Using at least 1 year of daily records from users, we analyzed the impact of the app on self-management of DM. METHODS: We have developed a mobile app that serves as an alternative form to the classic paper-based protocol or diary. The development was based on cooperation with both clinicians and people with DM. The app consists of independent individual modules. Therefore, the user has the possibility to use only selected features that they find useful. Mobiab was available free of charge on Google Play Store from mid-2014 until 2019. No targeted recruitment was performed to attract users. RESULTS: More than 500 users from the Czech Republic downloaded and signed up for the mobile app. Approximately 80% of the users used Mobiab for less than 1 week. The rest of the users used it for a longer time and 8 of the users produced data that were suitable for long-term analysis. Additionally, one of the 8 users provided their medical records, which were compared with the gathered data, and the improvements in their glucose levels and overall metabolic stability were consistent with the way in which the mobile app was used. CONCLUSIONS: The results of this study showed that the usability of a DM-centered self-management smartphone mobile app and server-based systems could be satisfactory and promising. Nonetheless, some better ways of motivating people with diabetes toward participation in self-management are needed. Further studies involving a larger number of participants are warranted to assess the effect on long-term diabetes management.
- Klíčová slova
- case study, diabetes mellitus, long-term data, mobile app, self-management,
- Publikační typ
- časopisecké články MeSH
CONTEXT: Gestational diabetes mellitus (GDM) is accompanied by subclinical inflammation; however, little is known about local inflammation in adipose tissue and placenta. OBJECTIVE: To analyze systemic and local subclinical inflammation and adipose tissue lymphocyte content and phenotype in pregnant women with and without GDM. DESIGN: Observational study. SETTINGS: Academic hospital. PATIENTS: Twenty-one pregnant women with GDM (GDM group), 16 pregnant women without GDM (non-GDM group) and 15 nonpregnant control women (N group). INTERVENTIONS: Serum samples taken at 28 to 32 (visit 1 [V1]) and 36 to 38 (V2) gestational weeks and 6 to 12 months after delivery (V3) in the GDM and non-GDM group and before elective gynecological surgery in the N group. Subcutaneous (SAT) and visceral adipose tissue (VAT) obtained during cesarean delivery or surgery. MAIN OUTCOME MEASURES: Serum levels and adipose tissue expression of proinflammatory cytokines, adipose tissue lymphocyte content and phenotype (for a subset of GDM and non-GDM subjects). RESULTS: Accented proinflammatory state in GDM was documented by increased circulating tumor necrosis factor-α (TNF-α) levels. In both groups of pregnant females total lymphocytes were higher in VAT compared to SAT. In GDM subjects B cells and NKT cells were higher in SAT compared to VAT and T helper cells were increased relative to SAT of non-GDM group, while no intercompartmental adipose tissue differences were seen in non-GDM women. CONCLUSIONS: Pregnant females had higher total lymphocyte count in VAT relative to SAT regardless of GDM. In addition to increased systemic subclinical inflammation, GDM was associated with significant differences in lymphocyte composition between subcutaneous and visceral adipose tissue depots.
- Klíčová slova
- adipose tissue, gestational diabetes mellitus, lymphocytes, subclinical inflammation,
- MeSH
- cytokiny krev MeSH
- dospělí MeSH
- gestační diabetes krev MeSH
- lidé MeSH
- lymfocyty metabolismus MeSH
- počet lymfocytů MeSH
- těhotenství MeSH
- tuková tkáň metabolismus MeSH
- zánět krev MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- Názvy látek
- cytokiny MeSH
BACKGROUND: The endoscopically implanted duodenal-jejunal bypass liner (DJBL) is an attractive alternative to bariatric surgery for obese diabetic patients. This article aims to study dynamical aspects of the glycaemic profile that may influence DJBL effects. METHODS: Thirty patients underwent DJBL implantation and were followed for 10 months. Continuous glucose monitoring (CGM) was performed before implantation and at month 10. Dynamical variables from CGM were measured: coefficient of variation of glycaemia, mean amplitude of glycaemic excursions (MAGE), detrended fluctuation analysis (DFA), % of time with glycaemia under 6.1 mmol/L (TU6.1), area over 7.8 mmol/L (AO7.8) and time in range. We analysed the correlation between changes in both anthropometric (body mass index, BMI and waist circumference) and metabolic (fasting blood glucose, FBG and HbA1c) variables and dynamical CGM-derived metrics and searched for variables in the basal CGM that could predict successful outcomes. RESULTS: There was a poor correlation between anthropometric and metabolic outcomes. There was a strong correlation between anthropometric changes and changes in glycaemic tonic control (∆BMI-∆TU6.1: rho = - 0.67, P < .01) and between metabolic outcomes and glycaemic phasic control (∆FBG-∆AO7.8: r = .60, P < .01). Basal AO7.8 was a powerful predictor of successful metabolic outcome (0.85 in patients with AO7.8 above the median vs 0.31 in patients with AO7.8 below the median: Chi-squared = 5.67, P = .02). CONCLUSIONS: In our population, anthropometric outcomes of DJBL correlate with improvement in tonic control of glycaemia, while metabolic outcomes correlate preferentially with improvement in phasic control. Assessment of basal phasic control may help in candidate profiling for DJBL implantation.
- Klíčová slova
- continuous glucose monitoring, detrended fluctuation analysis (DFA), diabesity, duodenal-jejunal bypass liner (DJBL), metabolic surgery, type 2 diabetes mellitus,
- MeSH
- biologické markery analýza MeSH
- diabetes mellitus 2. typu komplikace chirurgie MeSH
- dospělí MeSH
- duodenum chirurgie MeSH
- glykovaný hemoglobin analýza MeSH
- hmotnostní úbytek MeSH
- jejunum chirurgie MeSH
- krevní glukóza analýza MeSH
- lidé středního věku MeSH
- lidé MeSH
- metabolický syndrom etiologie prevence a kontrola MeSH
- morbidní obezita patofyziologie chirurgie MeSH
- následné studie MeSH
- prognóza MeSH
- senioři MeSH
- žaludeční bypass metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- biologické markery MeSH
- glykovaný hemoglobin MeSH
- hemoglobin A1c protein, human MeSH Prohlížeč
- krevní glukóza MeSH
Dendritic cells (DCs) are professional antigen-presenting cells contributing to regulation of lymphocyte immune response. DCs are divided into two subtypes: CD11c-positive conventional or myeloid (cDCs) and CD123-positive plasmacytoid (pDCs) DCs. The aim of the study was to assess DCs (HLA-DR+ lineage-) and their subtypes by flow cytometry in peripheral blood and subcutaneous (SAT) and epicardial (EAT) adipose tissue in subjects with (T2DM, n = 12) and without (non-T2DM, n = 17) type 2 diabetes mellitus undergoing elective cardiac surgery. Subjects with T2DM had higher fasting glycemia (8.6 ± 0.7 vs. 5.8 ± 0.2 mmol/l, p < 0.001) and glycated hemoglobin (52.0 ± 3.4 vs. 36.9 ± 1.0 mmol/mol, p < 0.001) and tended to have more pronounced inflammation (hsCRP: 9.8 ± 3.1 vs. 5.1 ± 1.9 mg/ml, p = 0.177) compared with subjects without T2DM. T2DM was associated with reduced total DCs in SAT (1.57 ± 0.65 vs. 4.45 ± 1.56% for T2DM vs. non-T2DM, p = 0.041) with a similar, albeit insignificant, trend in EAT (0.996 ± 0.33 vs. 2.46 ± 0.78% for T2DM vs. non-T2DM, p = 0.171). When analyzing DC subsets, no difference in cDCs was seen between any of the studied groups or adipose tissue pools. In contrast, pDCs were increased in both SAT (13.5 ± 2.0 vs. 4.6 ± 1.9% of DC cells, p = 0.005) and EAT (29.1 ± 8.7 vs. 8.4 ± 2.4% of DC, p = 0.045) of T2DM relative to non-T2DM subjects as well as in EAT of the T2DM group compared with corresponding SAT (29.1 ± 8.7 vs. 13.5 ± 2.0% of DC, p = 0.020). Neither obesity nor coronary artery disease (CAD) significantly influenced the number of total, cDC, or pDC in SAT or EAT according to multiple regression analysis. In summary, T2DM decreased the amount of total dendritic cells in subcutaneous adipose tissue and increased plasmacytoid dendritic cells in subcutaneous and even more in epicardial adipose tissue. These findings suggest a potential role of pDCs in the development of T2DM-associated adipose tissue low-grade inflammation.
- MeSH
- dendritické buňky metabolismus MeSH
- diabetes mellitus 2. typu imunologie metabolismus MeSH
- lidé středního věku MeSH
- lidé MeSH
- nemoci koronárních tepen imunologie metabolismus MeSH
- obezita imunologie metabolismus MeSH
- perikard imunologie metabolismus MeSH
- podkožní tuk imunologie metabolismus MeSH
- senioři MeSH
- tuková tkáň imunologie metabolismus MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
We performed a randomized controlled trial with the glucagon-like peptide-1 (GLP-1) receptor agonist exenatide as add-on to standard peri-operative insulin therapy in patients undergoing elective cardiac surgery. The aims of the study were to intensify peri-operative glucose control while minimizing the risk of hypoglycaemia and to evaluate the suggested cardioprotective effects of GLP-1-based treatments. A total of 38 patients with decreased left ventricular systolic function (ejection fraction ≤50%) scheduled for elective coronary artery bypass grafting (CABG) were randomized to receive either exenatide or placebo in a continuous 72-hour intravenous (i.v.) infusion on top of standard peri-operative insulin therapy. While no significant difference in postoperative echocardiographic variables was found between the groups, participants receiving exenatide showed improved peri-operative glucose control as compared with the placebo group (average glycaemia 6.4 ± 0.5 vs 7.3 ± 0.8 mmol/L; P < .001; percentage of time in target range of 4.5-6.5 mmol/L 54.8% ± 14.5% vs 38.6% ± 14.4%; P = .001; percentage of time above target range 39.7% ± 13.9% vs 52.8% ± 15.2%; P = .009) without an increased risk of hypoglycaemia (glycaemia <3.3 mmol/L: 0.10 ± 0.32 vs 0.21 ± 0.42 episodes per participant; P = .586). Continuous administration of i.v. exenatide in patients undergoing elective CABG could provide a safe option for intensifying the peri-operative glucose management of such patients.
- Klíčová slova
- cardiac surgery, exenatide, heart function, peri-operative glucose control,
- MeSH
- dysfunkce levé srdeční komory krev chirurgie MeSH
- exenatid MeSH
- hyperglykemie krev epidemiologie prevence a kontrola MeSH
- hypoglykemie krev chemicky indukované epidemiologie prevence a kontrola MeSH
- hypoglykemika aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- incidence MeSH
- inkretiny aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- intravenózní infuze MeSH
- inzulin aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- jednoduchá slepá metoda MeSH
- kardiotonika aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- kombinovaná farmakoterapie škodlivé účinky MeSH
- koronární bypass škodlivé účinky MeSH
- lidé MeSH
- nemocnice univerzitní MeSH
- ověření koncepční studie MeSH
- peptidy aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- perioperační péče škodlivé účinky MeSH
- peroperační komplikace krev chemicky indukované epidemiologie prevence a kontrola MeSH
- pooperační komplikace krev chemicky indukované epidemiologie prevence a kontrola MeSH
- receptor pro glukagonu podobný peptid 1 agonisté metabolismus MeSH
- riziko MeSH
- senioři MeSH
- srdce účinky léků patofyziologie MeSH
- živočišné jedy aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
- Názvy látek
- exenatid MeSH
- hypoglykemika MeSH
- inkretiny MeSH
- inzulin MeSH
- kardiotonika MeSH
- peptidy MeSH
- receptor pro glukagonu podobný peptid 1 MeSH
- živočišné jedy MeSH
Variability of pancreatic donors may significantly impact the success of islet isolation. The aim of this study was to evaluate donor factors associated with isolation failure and to investigate whether immunohistology could contribute to organ selection. Donor characteristics were evaluated for both successful (n = 61) and failed (n = 98) islet isolations. Samples of donor pancreatic tissue (n = 78) were taken for immunohistochemical examination. Islet isolations with 250000 islet equivalents were considered successful. We confirmed that BMI of less than 25 kg/m2 (P < 0.001), cold ischemia time more than 8 hours (P < 0.01), hospitalization longer than 96 hours (P < 0.05), higher catecholamine doses (P < 0.05), and edematous pancreases (P < 0.01) all unfavorably affected isolation outcome. Subsequent immunohistochemical examination of donor pancreases confirmed significant differences in insulin-positive areas (P < 0.001). ROC analyses then established that the insulin-positive area in the pancreas could be used to predict the likely success of islet isolation (P < 0.001). At the optimal cutoff point (>1.02%), sensitivity and specificity were 89% and 76%, respectively. To conclude, while the insulin-positive area, determined preislet isolation, as a single variable, is sufficient to predict isolation outcome and helps to improve the success of this procedure, its combination with the established donor scoring system might further improve organ selection.
- MeSH
- dárci tkání statistika a číselné údaje MeSH
- délka pobytu statistika a číselné údaje MeSH
- diabetes mellitus 1. typu chirurgie MeSH
- edém epidemiologie MeSH
- hospitalizace MeSH
- imunohistochemie MeSH
- index tělesné hmotnosti MeSH
- inzulin metabolismus MeSH
- Langerhansovy ostrůvky metabolismus chirurgie MeSH
- lidé MeSH
- pankreas MeSH
- retrospektivní studie MeSH
- studená ischemie statistika a číselné údaje MeSH
- transplantace Langerhansových ostrůvků metody MeSH
- vazokonstriktory terapeutické užití MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- inzulin MeSH
- vazokonstriktory MeSH
INTRODUCTION: Diabetic foot infections are frequently polymicrobial. The lower tissue concentration of systemically administered antibiotics in diabetic patients was reported. Collatamp(®)EG (Syntacoll GmbH Saal/Donau, Germany) is a bioabsorbable, gentamicin impregnated collagen spongeused for local treatment. The aim of this randomized trial was to assess influence of gentamicin-collagen sponge applied to a wound on surgical outcomes after minor amputations in diabetic patients. MATERIAL AND METHODS: Fifty diabetic patients indicated for minor amputation in 2009 at our surgery department were included in the study. Patients were pre-operatively randomised into two groups. Twenty-five patients in group A were treated with gentamicin impregnated collagen sponge applied into wound peri-operatively while 25 patients in group B had minor amputation without gentamicin sponge. RESULTS: There was no significant difference in the demographic data, procedures performed, diabetes duration and peripheral vascular disease severity between the groups. The median glycosylated haemoglobin was 6.0% (range: 4.6-9.5%) in group A and 6.2% (range: 4.0-8.4%) in control group B (non-significant). Median TcPO2 level was 44 (range: 13-67) in group A and 48 (range: 11-69) in control group B (non-significant). The median of wound healing duration in group A was 3.0 weeks (range: 1.7-17.1 weeks) compared to 4.9 weeks (range: 2.6-20.0 weeks) in control group B. This was with a statistically significant difference (p < 0.05). CONCLUSIONS: Application of gentamicin impregnated collagen sponge shortened wound healing duration after minor amputations in diabetic patients by almost 2 weeks.
- Klíčová slova
- amputation, diabetic foot, gentamicin, wound healing,
- Publikační typ
- časopisecké články MeSH