- Klíčová slova
- LAAC, NOAC, Rankin Scale, Stroke,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Strokes after left atrial appendage closure (LAAC) prophylaxis are generally less severe than those after warfarin prophylaxis-thought to be secondary to more hemorrhagic strokes with warfarin. Hemorrhagic strokes are similarly infrequent with direct oral anticoagulant (DOAC) prophylaxis, so the primary subtype after either LAAC or DOAC prophylaxis is ischemic stroke (IS). OBJECTIVES: The purpose of this study was to compare the severity of IS using the modified Rankin Scale in atrial fibrillation patients receiving prophylaxis with DOACs vs LAAC. METHODS: A retrospective analysis was performed of consecutive patients undergoing LAAC at 8 centers who developed an IS (ISLAAC) compared with contemporaneous consecutive patients who developed IS during treatment with DOACs (ISDOAC). The primary outcome was disabling/fatal stroke (modified Rankin Scale 3-5) at discharge and 3 months later. RESULTS: Compared with ISDOAC patients (n = 322), ISLAAC patients (n = 125) were older (age 77.2 ± 13.4 years vs 73.1 ± 11.9 years; P = 0.002), with higher HAS-BLED scores (3.0 vs 2.0; P = 0.004) and more frequent prior bleeding events (54.4% vs 23.6%; P < 0.001), but similar CHA2DS2-VASc scores (5.0 vs 5.0; P = 0.28). Strokes were less frequently disabling/fatal with ISLAAC than ISDOAC at both hospital discharge (38.3% vs 70.3%; P < 0.001) and 3 months later (33.3% vs 56.2%; P < 0.001). Differences in stroke severity persisted after propensity score matching. By multivariate regression analysis, ISLAAC was independently associated with fewer disabling/fatal strokes at discharge (OR: 0.22; 95% CI: 0.13-0.39; P < 0.001) and 3 months (OR: 0.25; 95% CI: 0.12-0.50; P < 0.001), and fewer deaths at 3 months (OR: 0.28; 95% CI: 0.12-0.64; P < 0.001). CONCLUSIONS: Ischemic strokes in patients with atrial fibrillation are less often disabling or fatal with LAAC than DOAC prophylaxis.
- Klíčová slova
- Rankin scale, anticoagulation, atrial fibrillation, left atrial appendage closure, non-vitamin K oral antagonist, stroke,
- MeSH
- antikoagulancia škodlivé účinky MeSH
- cévní mozková příhoda * epidemiologie etiologie prevence a kontrola MeSH
- fibrilace síní * komplikace farmakoterapie chirurgie MeSH
- hemoragická cévní mozková příhoda * chemicky indukované komplikace farmakoterapie MeSH
- ischemická cévní mozková příhoda * chemicky indukované komplikace farmakoterapie MeSH
- krvácení chemicky indukované MeSH
- lidé středního věku MeSH
- lidé MeSH
- retrospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- uzávěr ouška levé síně MeSH
- výsledek terapie MeSH
- warfarin škodlivé účinky MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- antikoagulancia MeSH
- warfarin MeSH
BACKGROUND: During electrophysiological mapping of tachycardias, putative target sites are often only truly confirmed to be vital after observing the effect of ablation. This lack of mapping specificity potentiates inadvertent ablation of innocent cardiac tissue not relevant to the arrhythmia. But if myocardial excitability could be transiently suppressed at critical regions, their suitability as targets could be conclusively determined before delivering tissue-destructive ablation lesions. We studied whether reversible pulsed electric fields (PFREV) could transiently suppress electrical conduction, thereby providing a means to dissect tachycardia circuits in vivo. METHODS: PFREV energy was delivered from a 9-mm lattice-tip catheter to the atria of 12 swine and 9 patients, followed by serial electrogram assessments. The effects on electrical conduction were explored in 5 additional animals by applying PFREV to the atrioventricular node: 17 low-dose (PFREV-LOW) and 10 high-dose (PFREV-HIGH) applications. Finally, in 3 patients manifesting spontaneous tachycardias, PFREV was applied at putative critical sites. RESULTS: In animals, the immediate post-PFREV electrogram amplitudes diminished by 74%, followed by 78% recovery by 5 minutes. Similarly, in patients, a 69.9% amplitude reduction was followed by 84% recovery by 3 minutes. Histology revealed only minimal to no focal, superficial fibrosis. PFREV-LOW at the atrioventricular node resulted in transient PR prolongation and transient AV block in 59% and 6%, while PFREV-HIGH caused transient PR prolongation and transient AV block in 30% and 50%, respectively. The 3 tachycardia patients had atypical atrial flutters (n=2) and atrioventricular nodal reentrant tachycardia. PFREV at putative critical sites reproducibly terminated the tachycardias; ablation rendered the tachycardias noninducible and without recurrence during 1-year follow-up. CONCLUSIONS: Reversible electroporation pulses can be applied to myocardial tissue to transiently block electrical conduction. This technique of pulsed field mapping may represent a novel electrophysiological tool to help identify the critical isthmus of tachycardia circuits.
- Klíčová slova
- catheters, electroporation, follow-up studies, swine, transients and migrants,
- MeSH
- atrioventrikulární blokáda * MeSH
- atrioventrikulární nodální reentry tachykardie * MeSH
- elektrofyziologické techniky kardiologické MeSH
- elektrokardiografie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- lidé MeSH
- nodus atrioventricularis MeSH
- prasata MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
AIMS: Single-shot pulmonary vein isolation can improve procedural efficiency. To assess the capability of a novel, expandable lattice-shaped catheter to rapidly isolate thoracic veins using pulsed field ablation (PFA) in healthy swine. METHODS AND RESULTS: The study catheter (SpherePVI; Affera Inc) was used to isolate thoracic veins in two cohorts of swine survived for 1 and 5 weeks. In Experiment 1, an initial dose (PULSE2) was used to isolate the superior vena cava (SVC) and the right superior pulmonary vein (RSPV) in six swine and the SVC only in two swine. In Experiment 2, a final dose (PULSE3) was used for SVC, RSPV, and left superior pulmonary vein (LSPV) in five swine. Baseline and follow-up maps, ostial diameters, and phrenic nerve were assessed. Pulsed field ablation was delivered atop the oesophagus in three swine. All tissues were submitted for pathology. In Experiment 1, all 14/14 veins were isolated acutely with durable isolation demonstrated in 6/6 RSPVs and 6/8 SVC. Both reconnections occurred when only one application/vein was used. Fifty-two and 32 sections from the RSPVs and SVC revealed transmural lesions in 100% with a mean depth of 4.0 ± 2.0 mm. In Experiment 2, 15/15 veins were isolated acutely with 14/15 veins (5/5 SVC, 5/5 RSPV, and 4/5 LSPV) durably isolated. Right superior pulmonary vein (31) and SVC (34) sections had 100% transmural, circumferential ablation with minimal inflammation. Viable vessels and nerves were noted without evidence of venous stenosis, phrenic palsy, or oesophageal injury. CONCLUSION: This novel expandable lattice PFA catheter can achieve durable isolation with transmurality and safety.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, Electroporation • Oesophageal injury, Pulmonary vein, Single shot,
- MeSH
- fibrilace síní * diagnóza chirurgie patologie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- katétry MeSH
- prasata MeSH
- studie proveditelnosti MeSH
- vena cava superior chirurgie MeSH
- venae pulmonales * chirurgie patologie MeSH
- výsledek terapie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Visually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. METHODS: Acute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. RESULTS: Acute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 ± 5.9, 33.7 ± 10.0, and 28.0 ± 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 ± 17.4% vs.91.9 ± 25.9%), and circumferentiality (95.8 ± 6.6% vs. 94.8 ± 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 ± 12.7 vs. 21.8 ± 3.8 min, p = .046 and 4.8 ± 3.83 vs. 35.4 ± 4.4, p < .001). CONCLUSION: Motor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.
- Klíčová slova
- atrial fibrillation, automated, catheter ablation, endoscopic, laser balloon,
- MeSH
- fibrilace síní * diagnóza chirurgie MeSH
- katetrizační ablace * škodlivé účinky MeSH
- laserová terapie * škodlivé účinky MeSH
- prasata MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Klíčová slova
- LAAC, LAAO, TEE, Watchman FLX, peri-device leak,
- MeSH
- incidence MeSH
- lidé MeSH
- septální okluder * MeSH
- síňové ouško * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.
- Klíčová slova
- Atrial fibrillation, Electroporation, Level of isolation, Pulmonary vein isolation, Pulsed field ablation,
- MeSH
- fibrilace síní * diagnóza chirurgie MeSH
- katetrizační ablace * metody MeSH
- kryochirurgie MeSH
- laserová terapie MeSH
- lidé MeSH
- radiofrekvenční ablace MeSH
- recidiva MeSH
- retrospektivní studie MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
BACKGROUND: The tissue specificity of pulsed field ablation (PFA) makes it an attractive energy source for pulmonary vein (PV) isolation (PVI). However, beyond each PFA lesion's zone of irreversible electroporation and cell death, there may be a surrounding zone of reversible electroporation and cell injury that could potentially normalize with time. OBJECTIVE: The purpose of this study was to assess whether the level of electrical PVI that is observed acutely after PFA regresses over time. METHODS: In a clinical trial, patients with paroxysmal atrial fibrillation underwent PVI using a biphasic PFA waveform delivered through a dedicated, variably deployable multielectrode basket/flower catheter. Detailed voltage maps were created using a multispline diagnostic catheter immediately after PFA and again ∼3 months later in a prospective, protocol-specified reassessment procedure. We analyzed 20 patients who underwent PFA with durable PVI and available maps from both time points. To compare the ablated zones, the left- and right-sided PV antral isolation areas and nonablated posterior wall area were quantified and the distances between left and right PV low-voltage edges were measured. RESULTS: A comparison of voltage maps immediately after PFA and at a median of 84 days (interquartile range 69-90 days) later revealed that there was no significant difference in either the left- and right-sided PV antral isolation areas or nonablated posterior wall area. The distances between low-voltage edges on the posterior wall were also not significantly different between the 2 time points. CONCLUSION: This study demonstrates that the level of PV antral isolation after PFA with a multielectrode PFA catheter persists without regression.
- Klíčová slova
- Atrial fibrillation, Electroporation, Level of isolation, Pulmonary vein isolation, Pulsed field ablation,
- MeSH
- časové faktory MeSH
- fibrilace síní patofyziologie chirurgie MeSH
- katetrizační ablace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- prospektivní studie MeSH
- studie proveditelnosti MeSH
- venae pulmonales chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Unlike for paroxysmal atrial fibrillation (AF), pulmonary vein isolation (PVI) alone is considered insufficient for many patients with persistent AF. Adjunctive ablation of the left atrial posterior wall (LAPW) may improve outcomes, but is limited by both the difficulty of achieving lesion durability and concerns of damage to the esophagus-situated behind the LAPW. OBJECTIVES: This study sought to assess the safety and lesion durability of pulsed field ablation (PFA) for both PVI and LAPW ablation in persistent AF. METHODS: PersAFOne is a single-arm study evaluating biphasic, bipolar PFA using a multispline catheter for PVI and LAPW ablation under intracardiac echocardiographic guidance. A focal PFA catheter was used for cavotricuspid isthmus ablation. No esophageal protection strategy was used. Invasive remapping was mandated at 2 to 3 months to assess lesion durability. RESULTS: In 25 patients, acute PVI (96 of 96 pulmonary veins [PVs]; mean ablation time: 22 min; interquartile range [IQR]: 15 to 29 min) and LAPW ablation (24 of 24 patients; median ablation time: 10 min; IQR: 6 to 13 min) were 100% acutely successful with the multispline PFA catheter alone. Using the focal PFA catheter, acute cavotricuspid isthmus block was achieved in 13 of 13 patients (median: 9 min; IQR: 6 to 12 min). The median total procedure time was 125 min (IQR: 108 to 166 min) (including a median of 28 min [IQR: 25 to 33 min] for voltage mapping), with a median of 16 min (IQR: 12 to 23 min) fluoroscopy. Post-procedure esophagogastroduodenoscopy and repeat cardiac computed tomography revealed no mucosal lesions or PV narrowing, respectively. Invasive remapping demonstrated durable isolation (defined by entrance block) in 82 of 85 PVs (96%) and 21 of 21 LAPWs (100%) treated with the pentaspline catheter. In 3 patients, there was localized scar regression of the LAPW ablation, albeit without conduction breakthrough. CONCLUSIONS: The unique safety profile of PFA potentiated efficient, safe, and durable PVI and LAPW ablation. This extends the potential role of PFA beyond paroxysmal to persistent forms of AF. (Pulsed Fields for Persistent Atrial Fibrillation [PersAFOne]; NCT04170621).
- Klíčová slova
- catheter ablation, esophagus, persistent atrial fibrillation, posterior wall, pulmonary vein isolation, pulsed field ablation,
- MeSH
- elektrokardiografie metody MeSH
- fibrilace síní diagnostické zobrazování chirurgie MeSH
- katetrizační ablace přístrojové vybavení metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- senioři MeSH
- srdeční katetrizace přístrojové vybavení metody MeSH
- venae pulmonales diagnostické zobrazování chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Pulmonary vein (PV) stenosis is an important potential complication of PV isolation using thermal modalities such as radiofrequency ablation (RFA). Pulsed field ablation (PFA) is an alternative energy that causes nonthermal myocardial cell death. OBJECTIVE: The purpose of this study was to compare the effect of PFA vs RFA on the incidence and severity of PV narrowing or stenosis. METHODS: Data were analyzed from 4 paroxysmal atrial fibrillation ablation trials using either PFA or RFA; because of absent CT scans or poor computed tomography scan quality, 73 of 153 patients (47.7%) were excluded. Baseline and 3-month cardiac computed tomography scans were reconstructed into 3-dimensional images, and the long and short axes of the PV ostia were quantitatively and qualitatively assessed in a randomized blinded manner by 2 physicians. RESULTS: A total of 299 PVs from 80 patients after either PFA (n = 37) or RFA (n = 43) were enrolled. PV ostial diameters decreased significantly less with PFA than with RFA (% change; long axis: 0.9% ± 8.5% vs -11.9% ± 16.3%; P < .001 and short axis: 3.4% ± 12.7% vs -12.9% ± 18.5%; P < .001). After a combined quantitative/qualitative analysis, mild (30%-49%), moderate (50%-69%), or severe (70%-100%) PV narrowing was observed, respectively, in 9.0% (15 of 166), 1.8% (3 of 166), and 1.2% (2 of 166) of PVs in the RFA cohort but in none of the PVs after PFA (P < .001). Overall, PV narrowing/stenosis was present in 0% and 0% vs 12.0% and 32.5% of PVs and patients who underwent PFA and RFA, respectively. CONCLUSION: This study indicates that unlike after RFA, the incidence and severity of PV narrowing/stenosis after PV isolation is virtually eliminated with PFA.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, Electroporation, Nonthermal ablation, Pulmonary vein stenosis, Pulsed field ablation,
- MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- počítačová rentgenová tomografie MeSH
- převodní systém srdeční patofyziologie MeSH
- venae pulmonales chirurgie MeSH
- výsledek terapie MeSH
- zobrazování trojrozměrné metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH