Mitral allografts are still used only exceptionally in the mitral or tricuspid position. The main indication remains infectious endocarditis of atrioventricular valves for its flexibility and low risk of infection. The aim of our study was to evaluate 1-year results of mitral allografts transplantation into the tricuspid position in a sheep model. Mitral allografts were processed, cryopreserved, and transplanted into the tricuspid position anatomically (Group I - 11 animals) or antianatomically (Group II - 8 animals). All survivors (4 from Group I, and 3 from Group II) were checked at 3, 6, and 12 months by echocardiography with the exception of one survivor from Group II (which was examinated only visually). Examination throughout follow-up included for mitral allograft regurgitation and annuli dilatation. At postmortem, the papillary muscles were healed and firmly anchored to the right ventricular wall in all subjects. Transventricular fixation of the papillary muscles with buttressed sutures was proven to be a stable, reproducible, and safe method for anchoring mitral allograft leaflets. There were no significant differences between the two implantation methods. Annulus support of mitral allografts might be very useful in this type of operation and could prevent annular dilatation.
- MeSH
- alografty MeSH
- kryoprezervace MeSH
- mitrální chlopeň transplantace MeSH
- modely u zvířat MeSH
- ovce MeSH
- trikuspidální chlopeň chirurgie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Prosthetic infective endocarditis is a possible complication of implantation of a prosthetic cardiac valve. Without early and effective treatment, it can have fatal consequences. One treatment option is use of an allogeneic cryopreserved homograft. This case report presents a 21-year old patient after kidney transplantation due to hereditary nephrotic syndrome and aortic valve replacement with aortic conduits. After fever was noted in the patient, prosthetic infective endocarditis was diagnosed by echocardiography and also confirmed by CT-3D examination. The cryopreserved aortic homograft was implanted at the Department of Cardiac Surgery. This along with additional conservative management effectively treated the infection. Based on literature data and our own experience, we believe that the treatment of prosthetic endocarditis after aortic valve replacement with cryopreserved homograft can be a method of choice.
- MeSH
- aortální chlopeň transplantace MeSH
- bakteriální endokarditida etiologie terapie MeSH
- dospělí MeSH
- homologní transplantace MeSH
- lidé MeSH
- mladý dospělý MeSH
- pooperační komplikace MeSH
- recidiva MeSH
- transplantace ledvin * MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- kazuistiky MeSH
Renal (kidney) transplantation is now a routine and the most successful form of renal replacement therapy. There is a long tradition of renal transplantation in the Czech Republic, The first was performed as early as 1961 in Hradec Kralove, and the programme as such was launched in 1966 with the first successful transplantation at the Institute of Experimental Surgery (later Institute for Clinical and Experimental Medicine, Prague). At present, transplantations are being performed at 7 transplantation centres (IKEM Prague, Centre for Cardiovascular and Transplantation Surgery Brno, Faculty Hospitals Hradec Kralove, Plzen, Olomouc and Ostrava and Faculty Hospital Motol for children). From the programme launch until the end of 2010, 8,761 renal transplantations were performed, 364 in 2010 alone. One-year patient and cadaver renal allograft survival, transplanted in the CR between 2000 and 2009, is around 95% and 92%, respectively, and 5-year survival is 87% and 81%, respectively. As of 31st December 2009, a total of 3,771 patients lived with functional renal allograft in the Czech Republic and the proportion of patients with irreversible renal failure treated with transplantation has recently been around 40%.
- MeSH
- lidé MeSH
- mrtvola MeSH
- transplantace ledvin mortalita statistika a číselné údaje MeSH
- žijící dárci MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
A mitral allograft is used exceptionally in the mitral, as well as in the tricuspid position, mostly as an experimental surgical procedure. The authors decided to evaluate the possibility of inserting a cryopreserved mitral allograft into the tricuspid position in a sheep experimental model. Within the framework of this experimental project the mechanical properties of the cryopreserved mitral allograft were tested. A novel methodology studying the functional unit composed of mitral annulus, leaflet, chordae tendinaea, and papillary muscle is presented. A five-parameter Maxwell model was applied to characterize the viscoelastic behavior of sheep mitral valves. A control group of 39 fresh mitral specimens and a test group of 13 cryopreserved mitral allografts from tissue bank were tested. The testing protocol consisted of six loading cycles with 1 mm elongation every 5 min. There was no significant difference in the mean values of the determined parameters (p>0.05) which confirms the main hypothesis that cryopreservation does not influence significantly material parameters characterizing the tissue mechanics. Slight discrepancy is observed in variances of viscous parameters suggesting that the values of the test group may be spread over larger interval due to the treatment.
INTRODUCTION: Aortic allograft implantation into the aortic position in adults is standard procedure with some controversary. The most popular indication is bacterial endocarditis. We would like to present our midterm results. RESULTS: We implanted 61 allografts in 60 patients (between 10/2002 and 04/2008). Men were 46 (76.8%) and average age was 57 +/- 10.76 year. 30 days mortality was 9 people (15.0%, all with bacterial endocarditis). Late mortality 1 man (1.6%). Follow up 1-66 months, average 39.18 SD +/- 14.3 months, median 42 months. CONCLUSION: Implantation of aortic allograft into the aortic position is standard procedure with good midterm results. Relative high early mortality is dependent on preoperative status in patiens with acute bacterial endocarditis--all early death people were people with acute bacterial endocarditis and minimally one vital organ severe dysfunction.
- MeSH
- aortální chlopeň patofyziologie chirurgie transplantace MeSH
- bakteriální endokarditida mortalita chirurgie MeSH
- dospělí MeSH
- homologní transplantace MeSH
- lidé středního věku MeSH
- lidé MeSH
- míra přežití MeSH
- mladý dospělý MeSH
- nemoci srdečních chlopní chirurgie MeSH
- reoperace MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
OBJECTIVE: Allograft heart valves (AHV), biological valves of human origin, offer potential advantages over conventional xenografts in terms of superior hemodynamics and, perhaps, better durability. The most important factors for long-term AHV clinical performance are the processing and cryopreservation methods. The aim of this study was to evaluate the impact of current processing protocol on valve tissue morphology, mainly to address the effect of successive processing steps on the leaflet surface structure. For the detection of fine changes in endothelial covering and underlying layers, our own modification of the scanning electron microscopy (SEM) technique was utilized. MATERIAL AND METHODS: The study was based on an investigation of 20 AHV (40 specimens). Fourteen valves came from heart-beating donors (multiorgan harvesting) when the heart could not be transplanted for any reason (donor criteria, availability of recipient and/or logistics). Six were obtained at the time of routine postmortems--non heart-beating donors (NHBD). All specimens were initially fixed in Baker's solution. Tissue samples were dissected, dried with hexamethyldisilazane (HMDS), gold-coated, studied and photographed by SEM (Tesla BS 301). In order to define the integrity of the endothelium, subendothelial layers and the quality of the surface under SEM, a special six-level score system was introduced: 1-intact endothelium, 2-confluent endothelium with structural inhomogeneity, 3-disruption of intercellular contacts, 4-separation of endothelial cells, 5-complete loss of endothelium, 6-damage of subendothelial layers). AHV samples were divided into 4 groups for comparison. One aortic AHV "fresh" control sample obtained from a heart-beating donor was evaluated without any processing and was compared with (i) tissue from AHV obtained from NHBD with warm ischemia of 12 and 48 hours, (ii) samples stored at +4 degrees C in saline for 24 h, (iii) antibiotic-treated tissue for 24 h at 37 degrees C and finally with (iv) cryopreserved valves stored in liquid nitrogen (-196 degrees C) for 6-38 months. RESULTS: Our alternative for drying samples by the HMDS method proved to be suitable for thin membranes of human semilunar valves. We were able to detect early changes in the endothelium after harvesting and denudation of the endothelial covering during preservation with and without freezing. The surface of the AHV samples revealed the typical features and score system determined endothelial cell damage. Control "fresh" sample: score 2, (i) NHBD samples with warm ischemia of 12 h: score 3-4, with warm ischemia of 48 h: score 4-5, (ii) samples stored at +4 degrees C in saline for 48 h: score 5-6, (iii) antibiotic-treated tissue for 24 h at 37 degrees C: score 5, (iv) cryopreserved valves stored in liquid nitrogen for 6-38 months: score 5-6. CONCLUSION: SEM (using HMDS drying) together with other methods may be helpful for the morphological control of processing, cryopreservation and liquid nitrogen storage of AHV. Severe AHV leaflet endothelial destruction was proven on AHV grafts. These changes arose already in the initial steps of tissue processing, just after the donor heart harvesting and then at the time of antibiotic valve graft treatment. These results are considered as the starting point for the development of a better preservation protocol.
- MeSH
- bazální membrána patologie MeSH
- cévní endotel patologie MeSH
- homologní transplantace MeSH
- kryoprezervace * MeSH
- lidé MeSH
- mikroskopie elektronová rastrovací * MeSH
- odběr tkání a orgánů MeSH
- povrchové vlastnosti MeSH
- srdeční chlopně patologie transplantace MeSH
- teplá ischemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
Still after 40 years of heart valve prostheses intensive development ideal valve substitute still does not exist. Aortic allograft represents one alternative which could be used for aortic and/or pulmonary valve replacement. This type of biological heart valve prosthesis is being currently discussed from the point of view of Tissue Banking, as well as from clinical aspects--e.g. surgical implantation technique and long term results. Live issue remains particularly the aortic allograft implantation into the aortic position. The authors discuss the aortic allograft role in the aortic valve infectious endocarditis treatment, which was widespread worldwide and accepted. Aortic allograft implantation is considered as a method of choice in that particular indication, especially in prosthetic aortic valve endocarditis and in left ventricle outlet tract destruction cases. The method is considered to be more technically demanding than routine heart valve surgery (heart valve replacement by means of mechanical or commercial biological prostheses), but literary and authors own experience in that particular group of patients looks encouraging. Aortic allografts permanent supply in our country is secured.
- MeSH
- aortální chlopeň transplantace MeSH
- bakteriální endokarditida chirurgie MeSH
- dospělí MeSH
- kardiochirurgické výkony metody MeSH
- lidé MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- přehledy MeSH
OBJECTIVE: The most important factors of long term clinical performance of biological heart valve prostheses are methods of processing and cryopreservation. That is why we decided to evaluate the impact of current Allograft Heart Valves (AHV) Bank protocol on valve tissue morphology. Scanning electron microscope (SEM) is a valuable tool for investigation of biological surfaces. In case of cardiac valves it is especially suitable for detection of fine changes in endothelial covering and underlying layers. MATERIAL AND METHODS: "Fresh" aortic and pulmonary AHV samples, harvested from "heart-beating" cadaveric donors, were compared with (1) tissue from AHV obtained from non heart-beating donors, (2) samples stored in 4 degrees C saline for 24 h, (3) antibiotic treated tissue for 24 h at 37 degrees C and finally (4) cryopreserved valves, stored in liquid nitrogen (-196 degrees C) for 6-38 months. All samples were dissected, dried with hexamethyldisilazane (HMDS), gold coated, studied and photographed by SEM (Tesla BS 301). RESULTS: Our alternative method of drying samples by the HMDS method proved to be suitable for thin membranes of human semilunar valves. We were able to detect early changes in the endothelium after harvesting, and denudation of the endothelial covering during preservation with and without freezing. CONCLUSION: SEM (using HMDS drying) along with other methods may be helpful for the morphological control of processing, cryopreservation and liquid nitrogen storage of AHV. According to the current findings we have to avoid washing of AHV in saline after harvesting.
Authors offer the case report of a patient with metastatic non differentiated carcinoma of sternum simultaneously suffering from ischemic heart disease. The patient underwent actinotherapy & hyperthermia followed by resection of sternum and coronary artery bypass grafting in one session. Chest wall defect was closed by means of latissimus dorsi muscle rotation. Postoperative palliative chemotherapy started 16 weeks postoperatively. Primary tumor was not found, neither preoperatively nor during the 36 months' postoperative remission.
- MeSH
- ischemická choroba srdeční komplikace chirurgie MeSH
- karcinom komplikace sekundární chirurgie MeSH
- koronární bypass * MeSH
- lidé středního věku MeSH
- lidé MeSH
- nádory kostí komplikace sekundární chirurgie MeSH
- sternum chirurgie MeSH
- torakoskopie metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- kazuistiky MeSH
Ischemic mitral regurgitation represents comparatively frequent complication of the myocardial infarction. Presence of the ischemic mitral regurgitation has a negative effect on the immediate mortality after the myocardial infarction and on the long-term survival. Ischemic mitral regurgitation is a functional, not structural impairment of the mitral valve and it is caused by altered geometry of the left ventricle. The article deals with the development and pathophysiology namely of the chronic ischemic mitral regurgitation and with the contemporary potential of surgical treatment of that serious complication of the ischemic heart disease.
- MeSH
- chronická nemoc MeSH
- infarkt myokardu komplikace MeSH
- ischemická choroba srdeční komplikace MeSH
- lidé MeSH
- mitrální chlopeň patofyziologie chirurgie MeSH
- mitrální insuficience etiologie patofyziologie chirurgie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- přehledy MeSH