Nejvíce citovaný článek - PubMed ID 17261999
Diagnosis and treatment of metal-induced side-effects
The objective of this study is to measure lymphocyte responses to metal antigens using MELISA (memory lymphocyte immunostimulation assay) test-modified lymphocyte transformation test (mLTT) and to evaluate metal sensitization in patients with and without the need of prosthetic surgery. This study is a case-control retrospective survey. We retrospectively analyzed all patients from 2013 to 2018 who were referred to the Institute of Dental Medicine, General University Hospital in Prague, and First Faculty of Medicine, Charles University, Prague, either following joint prosthesis-related complications or as a preoperative evaluation concerning metal hypersensitivity. For the control group, we selected healthy adults from our database. A group of 127 patients aged 25-81 years was chosen, 92 of which were female and 35 were male. The patients completed a special questionnaire aimed at information regarding their health status and history of metal exposure. After clinical examination, their peripheral blood samples were taken to perform mLTT. mLTT provided quantitative lymphocyte proliferation measurement, where a stimulation index of >2 indicated metal sensitivity. For statistical analysis, the Fisher's exact test, χ2 test, McNemar's exact test Student's paired t-test were used. By comparison of the study group and control group mLTT results, it can be stated that patients of the study group showed a higher level of lymphocyte reactivity to most of the tested metal antigens (Ag [silver], Cu [copper], Fe [iron], Mo [molybdenum], Pd [palladium], Pt [platinum], Ti [titanium], and Zn [zinc]) and an elevated incidence of metal hypersensitivity to Hg (mercury), Al (aluminum), Au (gold), Co (cobalt), Cr (chromium), Ni (nickel), and Sn (tin). The evaluation of the data obtained from patients in this study confirmed a significant clinical benefit of mLTT in diagnostics of metal hypersensitivity. Our study has revealed that the patients with the need of prosthetic surgery exhibited an elevated lymphocyte response to metal antigens. This result supports a metal-specific adaptive immune response and suggests involvement of metal exposure as a trigger for their health problems. This knowledge could be helpful in effectively enhancing the treatment of patients with need of orthopedic joint prosthesis.
- Klíčová slova
- arthroplasty, hypersensitivity, lymphocyte, metal, modified lymphocyte transformation test (mLTT),
- MeSH
- aktivace lymfocytů MeSH
- alergie * etiologie diagnóza imunologie MeSH
- dospělí MeSH
- kovy * škodlivé účinky imunologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- lymfocyty * imunologie MeSH
- protézy kloubů * škodlivé účinky MeSH
- retrospektivní studie MeSH
- selhání protézy * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- studie případů a kontrol MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- kovy * MeSH
This study is aimed at proving the clinical benefit of the MELISA® test in the minimization or complete elimination of health problems in patients with confirmed hypersensitivity to metals used for tissue replacements. A group of 305 patients aged 20-75 years with previously proven metal hypersensitivity (initial MELISA® test), mainly to titanium and then to another fifteen metals, was chosen from the database at the Institute of Dental Medicine. From these patients, a final group of 42 patients agreed to participate in the study, 35 of which were female and 7 were male. The patients completed a special questionnaire aimed at information regarding change of health status from their last visit and determining whether the results of the initial MELISA® test and recommendations based on it were beneficial for patients or not. They were clinically examined, and peripheral blood samples were taken to perform follow-up MELISA® tests. Questionnaire data was processed, and the follow-up MELISA® test results were compared with the results of the initial MELISA® tests. For statistical analysis, the Fisher's exact test and paired T-test were used. Thirty-two patients reported that they followed the recommendations based on the results of the initial MELISA® tests, and of these, 30 patients (94%) confirmed significant health improvement. Six patients did not follow the recommendation, and from these, only one patient reported an improvement in his health problems. By comparison of the initial and follow-up MELISA® test results, it can be stated that the hypersensitivity to the given metal decreased or disappeared after the therapeutic interventions performed based on the initial MELISA® test results. The evaluation of the data obtained from patients in this study confirmed a significant clinical benefit of MELISA® test.
- MeSH
- alergie diagnóza MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- průzkumy a dotazníky * MeSH
- senioři MeSH
- titan škodlivé účinky MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- Názvy látek
- titan MeSH
Dental implants are often made of titanium alloys. Implant therapy currently promises a good long-term result without impacting health; however, its success depends on many factors. In this article, the authors focus on the most common risk factors associated with metallic surgical implants. Titanium-induced hypersensitivity can lead to symptoms of implant rejection. Corrosion and biofilm formation are additional situations in which these symptoms may occur. For medical purposes, it is important to define and discuss the characteristics of metals used in implantable devices and to ensure their biocompatibility. To avoid hypersensitivity reactions to metallic dental implants, precautionary principles for primary prevention should be established.
- MeSH
- biokompatibilní materiály škodlivé účinky terapeutické užití MeSH
- koroze MeSH
- kovy škodlivé účinky terapeutické užití MeSH
- lidé MeSH
- rizikové faktory MeSH
- titan škodlivé účinky terapeutické užití MeSH
- zubní implantáty škodlivé účinky MeSH
- zubní slitiny škodlivé účinky terapeutické užití MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- Názvy látek
- biokompatibilní materiály MeSH
- kovy MeSH
- titan MeSH
- zubní implantáty MeSH
- zubní slitiny MeSH