Nejvíce citovaný článek - PubMed ID 22383237
Does higher gadolinium concentration play a role in the morphologic assessment of brain tumors? Results of a multicenter intraindividual crossover comparison of gadobutrol versus gadobenate dimeglumine (the MERIT Study)
OBJECTIVES: Accurate detection of metastatic brain lesions (MBL) is critical due to advances in radiosurgery. We compared the results of three readers in detecting MBL using T1-weighted 2D spin echo (SE) and sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) sequences with whole-brain coverage at both 1.5 T and 3 T. METHODS: Fifty-six patients evaluated for MBL were included and underwent a standard protocol (1.5 T, n = 37; 3 T, n = 19), including postcontrast T1-weighted SE and SPACE. The rating was performed by three raters in two sessions > six weeks apart. The true number of MBL was determined using all available imaging including follow-up. Intraclass correlations for intra-rater and inter-rater agreement were calculated. Signal intensity ratios (SIR; enhancing lesion, white matter) were determined on a subset of 46 MBL > 4 mm. A paired t-test was used to evaluate postcontrast sequence order and SIR. Reader accuracy was evaluated by the coefficient of determination. RESULTS: A total of 135 MBL were identified (mean/subject 2.41, SD 6.4). The intra-rater agreement was excellent for all 3 raters (ICC = 0.97-0.992), as was the inter-rater agreement (ICC = 0.995 SE, 0.99 SPACE). Subjective qualitative ratings were lower for SE images; however, signal intensity ratios were higher in SE sequences. Accuracy was high in all readers for both SE (R2 0.95-0.96) and SPACE (R2 0.91-0.96) sequences. CONCLUSIONS: Although SE sequences are superior to gradient echo sequences in the detection of small MBL, they have long acquisition times and frequent artifacts. We show that T1-weighted SPACE is not inferior to standard thin-slice SE sequences in the detection of MBL at both imaging fields. CRITICAL RELEVANCE STATEMENT: Our results show the suitability of 3D T1-weighted turbo spin echo (TSE) sequences (SPACE, CUBE, VISTA) in the detection of brain metastases at both 1.5 T and 3 T. KEY POINTS: • Accurate detection of brain metastases is critical due to advances in radiosurgery. • T1-weighted SE sequences are superior to gradient echo in detecting small metastases. • T1-weighted 3D-TSE sequences may achieve high resolution and relative insensitivity to artifacts. • T1-weighted 3D-TSE sequences have been recommended in imaging brain metastases at 3 T. • We found T1-weighted 3D-TSE equivalent to thin-slice SE at 1.5 T and 3 T.
- Klíčová slova
- Brain metastasis, Imaging sequences, Magnetic resonance imaging, Radiosurgery,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Concerns over gadolinium (Gd) retention encourage the use of lower Gd doses. However, lower Gd doses may compromise imaging performance. Higher relaxivity gadobenate may be suited to reduced dose protocols. PURPOSE: To compare 0.05 mmol/kg and 0.1 mmol/kg gadobenate in patients undergoing enhanced MRI of the central nervous system (CNS). STUDY TYPE: Retrospective, multicenter. POPULATION: Three hundred and fifty-two patients receiving 0.05 (n = 181) or 0.1 (n = 171) mmol/kg gadobenate. FIELD STRENGTH/SEQUENCES: 1.5 T and 3.0 T/precontrast and postcontrast T1-weighted spin echo/fast spin echo (SE/FSE) and/or gradient echo/fast field echo (GRE/FFE); precontrast T2-weighted FSE and T2-FLAIR. ASSESSMENT: Images of patients with extra-axial lesions at 1.5 T or any CNS lesion at 3.0 T were reviewed by three blinded, independent neuroradiologists for qualitative (lesion border delineation, internal morphology visualization, contrast enhancement; scores from 1 = poor to 4 = excellent) and quantitative (lesion-to-brain ratio [LBR], contrast-to-noise ratio [CNR]; SI measurements at regions-of-interest on lesion and normal parenchyma) enhancement measures. Noninferiority of 0.05 mmol/kg gadobenate was determined for each qualitative endpoint if the lower limit of the 95% confidence interval (CI) for the difference in precontrast + postcontrast means was above a noninferiority margin of -0.4. STATISTICAL TESTS: Student's t-test for comparison of mean qualitative endpoint scores, Wilcoxon signed rank test for comparison of LBR and CNR values; Wilcoxon rank sum test for comparison of SI changes. Tests were significant for P < 0.05. RESULTS: The mean change from precontrast to precontrast + postcontrast was significant for all endpoints. Readers 1, 2, and 3 evaluated 304, 225, and 249 lesions for 0.05 mmol/kg gadobenate, and 382, 309, and 298 lesions for 0.1 mmol/kg gadobenate. The lower limit of the 95% CI was above -0.4 for all comparisons. Significantly, higher LBR and CNR was observed with the higher dose. DATA CONCLUSION: 0.05 mmol/kg gadobenate was noninferior to 0.1 mmol/kg gadobenate for lesion visualization. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 3.
- Klíčová slova
- GBCA safety, comparative studies, contrast efficacy, gadobenate dimeglumine,
- MeSH
- diethylentriaminpentaacetát gadolinia MeSH
- kontrastní látky MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- meglumin analogy a deriváty MeSH
- mozek diagnostické zobrazování MeSH
- nádory mozku * MeSH
- organokovové sloučeniny * MeSH
- retrospektivní studie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- Názvy látek
- diethylentriaminpentaacetát gadolinia MeSH
- gadobenic acid MeSH Prohlížeč
- kontrastní látky MeSH
- meglumin MeSH
- organokovové sloučeniny * MeSH
BACKGROUND AND PURPOSE: Gadobenate dimeglumine (MultiHance) has higher r1 relaxivity than gadoterate meglumine (Dotarem) which may permit the use of lower doses for MR imaging applications. Our aim was to compare 0.1- and 0.05-mmol/kg body weight gadobenate with 0.1-mmol/kg body weight gadoterate for MR imaging assessment of brain tumors. MATERIALS AND METHODS: We performed crossover, intraindividual comparison of 0.1-mmol/kg gadobenate with 0.1-mmol/kg gadoterate (Arm 1) and 0.05-mmol/kg gadobenate with 0.1-mmol/kg gadoterate (Arm 2). Adult patients with suspected or known brain tumors were randomized to Arm 1 (70 patients) or Arm 2 (107 patients) and underwent 2 identical examinations at 1.5 T. The agents were injected in randomized-sequence order, and the 2 examinations were separated by 2-14 days. MR imaging scanners, imaging sequences (T1-weighted spin-echo and T1-weighted high-resolution gradient-echo), and acquisition timing were identical for the 2 examinations. Three blinded readers evaluated images for diagnostic information (degree of definition of lesion extent, lesion border delineation, visualization of lesion internal morphology, contrast enhancement) and quantitatively for percentage lesion enhancement and lesion-to-background ratio. Safety assessments were performed. RESULTS: In Arm 1, a highly significant superiority (P < .002) of 0.1-mmol/kg gadobenate was demonstrated by all readers for all end points. In Arm 2, no significant differences (P > .1) were observed for any reader and any end point, with the exception of percentage enhancement for reader 2 (P < .05) in favor of 0.05-mmol/kg gadobenate. Study agent-related adverse events were reported by 2/169 (1.2%) patients after gadobenate and by 5/175 (2.9%) patients after gadoterate. CONCLUSIONS: Significantly superior morphologic information and contrast enhancement are demonstrated on brain MR imaging with 0.1-mmol/kg gadobenate compared with 0.1-mmol/kg gadoterate. No meaningful differences were recorded between 0.05-mmol/kg gadobenate and 0.1-mmol/kg gadoterate.
- MeSH
- dospělí MeSH
- klinické křížové studie MeSH
- kontrastní látky MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- meglumin analogy a deriváty MeSH
- nádory mozku patologie MeSH
- organokovové sloučeniny MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
- Názvy látek
- gadobenic acid MeSH Prohlížeč
- gadoterate meglumine MeSH Prohlížeč
- kontrastní látky MeSH
- meglumin MeSH
- organokovové sloučeniny MeSH
BACKGROUND AND PURPOSE: Gadobutrol (Gadavist) and gadoteridol (ProHance) have similar macrocyclic molecular structures, but gadobutrol is formulated at a 2-fold higher (1 mol/L versus 0.5 mol/L) concentration. We sought to determine whether this difference impacts morphologic contrast-enhanced MR imaging. MATERIALS AND METHODS: Two hundred twenty-nine adult patients with suspected or known brain tumors underwent two 1.5T MR imaging examinations with gadoteridol or gadobutrol administered in randomized order at a dose of 0.1 mmol/kg of body weight. Imaging sequences and T1 postinjection timing were identical for both examinations. Three blinded readers evaluated images qualitatively and quantitatively for lesion detection and for accuracy in characterization of histologically confirmed brain tumors. Data were analyzed by using the Wilcoxon signed rank test, the McNemar test, and a mixed model. RESULTS: Two hundred nine patients successfully completed both examinations. No reader noted a significant qualitative or quantitative difference in lesion enhancement, extent, delineation, or internal morphology (P values = .69-1.00). One hundred thirty-nine patients had at least 1 histologically confirmed brain lesion. Two readers found no difference in the detection of patients with lesions (133/139 versus 135/139, P = .317; 137/139 versus 136/139, P = .564), while 1 reader found minimal differences in favor of gadoteridol (136/139 versus 132/139, P = .046). Similar findings were noted for the number of lesions detected and characterization of tumors (malignant/benign). Three-reader agreement for characterization was similar for gadobutrol (66.4% [κ = 0.43]) versus gadoteridol (70.3% [κ = 0.45]). There were no significant differences in the incidence of adverse events (P = .199). CONCLUSIONS: Gadoteridol and gadobutrol at 0.1 mmol/kg of body weight provide similar information for visualization and diagnosis of brain lesions. The 2-fold higher gadolinium concentration of gadobutrol provides no benefit for routine morphologic imaging.
- MeSH
- dospělí MeSH
- gadolinium aplikace a dávkování MeSH
- heterocyklické sloučeniny aplikace a dávkování MeSH
- klinické křížové studie MeSH
- kontrastní látky aplikace a dávkování MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- nádory mozku diagnóza MeSH
- neurozobrazování metody MeSH
- organokovové sloučeniny aplikace a dávkování MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- Názvy látek
- gadobutrol MeSH Prohlížeč
- gadolinium MeSH
- gadoteridol MeSH Prohlížeč
- heterocyklické sloučeniny MeSH
- kontrastní látky MeSH