AIMS: Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation. METHODS AND RESULTS: A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies. CONCLUSION: In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.
- Klíčová slova
- Cardiac resynchronization therapy, Clinical outcomes, Echocardiographic outcomes, Electrically, Guided, Imaging, Latest activation, Targeting left ventricular lead position,
- MeSH
- echokardiografie MeSH
- hospitalizace MeSH
- lidé MeSH
- srdeční komory diagnostické zobrazování MeSH
- srdeční resynchronizační terapie * škodlivé účinky MeSH
- srdeční selhání * diagnóza terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- systematický přehled MeSH
Background: The aim of this study was to evaluate left ventricular mechanical activation pattern by speckle tracking echocardiography (STE) as a predictor of response to cardiac resynchronization therapy (CRT) in patients with heart failure. Methods: Echocardiography was performed during no pacing, right ventricular pacing (RVP), biventricular pacing (BVP) and multipolar pacing (MPP) immediately after CRT implantation in 16 patients at a single centre. Seven patients were diagnosed as responders and 9 patients as non-responders after 6 months of standard CRT pacing. All had adequate short axis views, and 1 CRT responder and 2 CRT non-responders had limited longitudinal views. Results: Longitudinal and circumferential global strain (GS) and global strain rate (GSR) or their change analysis, did not yield any CRT response prediction. However, the longitudinal BVP/RVP GS ratio was significantly higher in the responder group (1.32 ± 0.2%, 2.0 ± 0.4% and 1.9 ± 0.4%), compared with the non-responder group (1.06 ± 0.2%, 1.1 ± 0.4% and 1.2 ± 0.4%) in the apical two-chamber, APLAX and four-chamber views, respectively. Similarly, the longitudinal BVP/RVP GSR at active systolic phase (GSRs) was significantly higher in the responder group (1.9 ± 0.9% and 1.7 ± 0.4%) compared with the non-responder group (1.0 ± 0.4% and 1.1 ± 0.2%) in the apical APLAX and four-chamber views, respectively. Measurements of the strain delay index showed predictive power regarding CRT response in non-paced patients. Conclusion: Post implantation, longitudinal BVP/RVP GS and GSRs ratios of 1.4% and above may be useful as a CRT response prediction tool. Furthermore, our findings support the usefulness of strain delay index prior to CRT implantation in non-paced patients.
- Klíčová slova
- Heart failure, cardiac resynchronization therapy, echocardiography, response prediction, speckle tracking,
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Cardiac resynchronization therapy is an effective and widely accessible treatment for patients with advanced, drug-refractory heart failure. It has been shown to reverse maladaptive ventricular remodeling, increase exercise capacity, and lower hospitalization and mortality rates. However, there still exists a considerable proportion of patients who do not respond favorably to the therapy. Tailored left ventricular (LV) lead positioning instead of empiric implantation is thought to have the greatest potential to increase response rates. In our paper, we focus on the rationale for guided LV lead implantation and provide a review of the non-invasive imaging modalities applicable for navigation during LV lead implantation, with special attention to the latest achievements in the field of multimodality imaging and image fusion techniques. Current limitations and future perspectives of the concept are discussed as well.
- Klíčová slova
- Cardiac resynchronization, Coronary sinus, Guided implantation, Image fusion, Mechanical activation, Multimodality imaging, Myocardial scar, Non-responder,
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH