Nejvíce citovaný článek - PubMed ID 25853744
OBJECTIVES: Current recommendations support surgical treatment of atrial fibrillation (AF) in patients indicated for cardiac surgery. These procedures are referred to as concomitant and may be carried out using radiofrequency energy or cryo-ablation. This study aimed to assess the electrophysiological findings in patients undergoing concomitant cryo-ablation. METHODS: Patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement were included in the trial if concomitant cryo-ablation was part of the treatment plan according to current guidelines. The patients reported in this study were assigned to undergo staged percutaneous radiofrequency catheter ablation (PRFCA), i.e., hybrid treatment, as a part of the SURHYB trial protocol. RESULTS: We analyzed 103 patients who underwent PRFCA 105 ± 35 days after surgery. Left and right pulmonary veins (PVs) were found isolated in 65 (63.1%) and 63 (61.2%) patients, respectively. The LA posterior wall isolation and mitral isthmus conduction block were found in 38 (36.9%) and 18 (20.0%) patients, respectively. Electrical reconnections (gaps) in the left PVs were more often localized superiorly than inferiorly (57.9% vs. 26.3%, P = 0.005) and anteriorly than posteriorly (65.8% vs. 31.6%, P = 0.003). Gaps in the right PVs were more equally distributed anteroposteriorly but dominated in superior segments (72.5% vs. 40.0%, P = 0.003). There was a higher number of gaps on the roof line compared to the inferior line (131 (67.2%) vs. 67 (42.2%), P < 0.001). Compared to epicardial cryo-ablation, endocardial was more effective in creating PVs and LA posterior wall isolation (P < 0.05). Cryo-ablation using nitrous oxide (N20) or argon (Ar) gas as cooling agents was similarly effective (P = NS). CONCLUSIONS: The effectiveness of surgical cryo-ablation in achieving transmural and durable lesions in the left atrium is surprisingly low. Gaps are located predominantly in the superior and anterior portions of the PVs and on the roof line. Endocardial cryo-ablation is more effective than epicardial ablation, irrespective of the cooling agent used.
- Klíčová slova
- Concomitant atrial fibrillation ablation, CryoMaze procedure, Electrical conduction, Electrophysiological study, Gaps localization, Staged hybrid ablation,
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * metody MeSH
- koronární bypass metody MeSH
- kryochirurgie * metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether the timely pre-emptive catheter ablation would achieve higher freedom from AF or atrial tachycardia (AT) and be associated with better clinical outcomes than surgical ablation alone. METHODS AND RESULTS: The trial investigated patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with mandatory concomitant CryoMaze procedure who were randomly assigned to undergo either radiofrequency catheter ablation [Hybrid Group (HG)] or no further treatment (Surgery Group). The primary efficacy endpoint was the first recurrence of AF/AT without class I or III antiarrhythmic drugs as assessed by implantable cardiac monitors. The primary clinical endpoint was a composite of hospitalization for arrhythmia recurrence, worsening of heart failure, cardioembolic event, or major bleeding. We analysed 113 and 116 patients in the Hybrid and Surgery Groups, respectively, with a median follow-up of 715 (IQR: 528-1072) days. The primary efficacy endpoint was significantly reduced in the HG [41.1% vs. 67.4%, hazard ratio (HR) = 0.38, 95% confidence interval (CI): 0.26-0.57, P < 0.001] as well as the primary clinical endpoint (19.9% vs. 40.1%, HR = 0.51, 95% CI: 0.29-0.86, P = 0.012). The trial groups did not differ in all-cause mortality (10.6% vs. 8.6%, HR = 1.17, 95%CI: 0.51-2.71, P = 0.71). The major complications of catheter ablation were infrequent (1.9%). CONCLUSION: Pre-emptively performed catheter ablation after the CryoMaze procedure was safe and associated with higher freedom from AF/AT and improved clinical outcomes.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, Concomitant atrial fibrillation ablation, Hybrid ablation, Maze procedure,
- MeSH
- antiarytmika terapeutické užití MeSH
- fibrilace síní * diagnóza chirurgie farmakoterapie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- krvácení MeSH
- lidé MeSH
- recidiva MeSH
- supraventrikulární tachykardie * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- Názvy látek
- antiarytmika MeSH
- Klíčová slova
- Ablation, Anticoagulation, Arrhythmia, Atrial fibrillation, Atrial flutter, Atrial tachycardia, Catheter ablation, Stroke, Surgical ablation,
- MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace škodlivé účinky normy MeSH
- konsensus MeSH
- kryochirurgie škodlivé účinky normy MeSH
- lidé MeSH
- rizikové faktory MeSH
- srdeční katetrizace škodlivé účinky normy MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- směrnice pro lékařskou praxi MeSH
- Klíčová slova
- Ablation, Anticoagulation, Arrhythmia, Atrial fibrillation, Atrial flutter, Atrial tachycardia, Catheter ablation, Stroke, Surgical ablation,
- MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace škodlivé účinky normy MeSH
- konsensus MeSH
- kryochirurgie škodlivé účinky normy MeSH
- lidé MeSH
- rizikové faktory MeSH
- srdeční katetrizace škodlivé účinky normy MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- směrnice pro lékařskou praxi MeSH
- Klíčová slova
- AAD, antiarrhythmic drug, AF, atrial fibrillation, AFL, atrial flutter, Ablation, Anticoagulation, Arrhythmia, Atrial fibrillation, Atrial flutter, Atrial tachycardia, CB, cryoballoon, CFAE, complex fractionated atrial electrogram, Catheter ablation, LA, left atrial, LAA, left atrial appendage, LGE, late gadolinium-enhanced, LOE, level of evidence, MRI, magnetic resonance imaging, OAC, oral anticoagulation, RF, radiofrequency, Stroke, Surgical ablation,
- Publikační typ
- časopisecké články MeSH
- Klíčová slova
- Ablation, Anticoagulation, Arrhythmia, Atrial fibrillation, Atrial flutter, Atrial tachycardia, Catheter ablation, Stroke, Surgical ablation,
- MeSH
- ablace normy MeSH
- fibrilace síní chirurgie MeSH
- kardiologie * MeSH
- katetrizační ablace normy MeSH
- konsensuální konference jako téma * MeSH
- lidé MeSH
- převodní systém srdeční chirurgie MeSH
- společnosti lékařské * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- zprávy MeSH
- Klíčová slova
- Ablation, Anticoagulation, Arrhythmia, Atrial fibrillation, Atrial flutter, Atrial tachycardia, Catheter ablation, Stroke, Surgical ablation,
- MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- kardiochirurgické výkony normy MeSH
- katetrizační ablace normy MeSH
- konsensus MeSH
- lidé MeSH
- rizikové faktory MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH